Issue 7, 2000

Abstract

Inductively coupled plasma mass spectrometry (ICP-MS) has been used for the determination of trace elements in a variety of materials. For uranium, the concentration of 238U can be measured with a detection limit of less than 0.1 ppt in a few minutes. However, because of the extremely low 234U concentrations in environmental materials, it is necessary to separate U from the matrices and to remove interfering elements from the sample solution for measurement of the 238U/234U ratio by ICP-MS. In this study, a simple and rapid separation method for U with an extraction chromatographic resin (TEVA resin) was developed for ICP-MS and the U isotopic ratios in phosphogypsum samples, collected in Spain, were measured. The resin efficiently retained U in 6 M HCl medium and more than 98% of the U was easily eluted with the first 30 mL of 0.1 M HNO3. The separated solutions were free from most of the matrix elements and the concentrations of U in the solutions ranged from 35 to 70 ppb. The 238U/234U isotopic ratios in the solutions were measured by ICP-MS. Moreover, due to the presence of a higher number of 235U atoms in comparison with 234U, the 238U/235U isotopic ratios were also determined with high precision by ICP-MS. The results obtained agreed well with the ratios measured by alpha-spectrometry. The method for this determination is more rapid than alpha-spectrometry, and is considered to be more suitable for environmental monitoring.

Article information

Article type
Inter-laboratory Note
Submitted
17 Feb 2000
Accepted
17 Apr 2000
First published
14 Jun 2000

J. Anal. At. Spectrom., 2000,15, 889-892

Determination of U isotopic ratios in environmental samples by ICP-MS

S. Uchida, R. García-Tenorio, K. Tagami and M. García-León, J. Anal. At. Spectrom., 2000, 15, 889 DOI: 10.1039/B001332N

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements