Issue 7, 1996

Determination of pyrogallol using continuous flow with chemiluminescence detection

Abstract

Pyrogallol is determined by means of chemiluminescence at 500 nm which accompanies the oxidation by hydrogen peroxide of autoxidized pyrogallol in the presence of chromium(III) and formaldehyde. Using air-segmented continuous flow analysis, the LOD (3s) was 6.0 × 10–9 mol dm–3 and the calibration was linear up to 10–4 mol dm–3. The method has the potential to be extended to other phenols.

Article information

Article type
Paper

Anal. Commun., 1996,33, 241-243

Determination of pyrogallol using continuous flow with chemiluminescence detection

N. J. Kearney, E. S. Bridgeland, R. A. Jewsbury, N. D. Martin, S. J. Kelly and S. R. Korn, Anal. Commun., 1996, 33, 241 DOI: 10.1039/AC9963300241

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.