Issue 4, 1996

Determination of amitriptyline using electrogenerated chemiluminescence

Abstract

A novel method for the selective and sensitive determination of amitriptyline, a tricyclic antidepressant, using electrogenerated chemiluminescence (ECL) is described. The ECL mechanism is based on the reaction between tris(2,2′-bipyridyl)ruthenium(II)[Ru(bpy)32+] and the tertiary amino group on amitriptyline. After optimizing the experimental conditions, a calibration over three orders of magnitude of concentration, was obtained. A linear calibration plot was constructed in order to evaluate the limit of detection, which was determined as 3.0 × 10–7 mol l–1(94 ppb) with an average %sr of 2.14 for 5 replicate measurements.

Article information

Article type
Paper

Anal. Commun., 1996,33, 139-141

Determination of amitriptyline using electrogenerated chemiluminescence

S. J. L. Dolman and G. M. Greenway, Anal. Commun., 1996, 33, 139 DOI: 10.1039/AC9963300139

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.