Issue 2, 1992

Linear titration plot for the determination of boron in the primary coolant of a pressurized water reactor

Abstract

A linear titration plot method has been devised for the determination of boron as boric acid in partly neutralized solution, such as occurs in the primary coolant of pressurized water reactors. The total boron and the alkali in the sample are determined simultaneously. Although it is not essential to add mannitol in this method, it is more accurate when the solution is saturated with mannitol. Comparisons are made with other modes of titration: Gran plots, first and second differential potentiometric titrations and indicator titrations. None of these gives the total boron directly in partly neutralized solutions.

Article information

Article type
Paper

Analyst, 1992,117, 199-202

Linear titration plot for the determination of boron in the primary coolant of a pressurized water reactor

D. Midgley and C. Gatford, Analyst, 1992, 117, 199 DOI: 10.1039/AN9921700199

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements