Issue 2, 1991

Elimination of copper interference by continuous flow matrix isolation in the determination of selenium by flow injection hydride generation atomic absorption spectrometry

Abstract

A flow system incorporating a microcolumn of strongly acidic cation-exchange resin (Dowex 50W) to achieve continuous flow matrix isolation was used to eliminate copper interference in the determination of selenium by flow injection hydride generation atomic absorption spectrometry. The microcolumn manifold used for the selective retention of the copper interferent was interfaced with the hydride generation manifold through a flow injection sample injection valve. The two manifolds were made independent of each other in order to achieve optimum performance characteristics for both the matrix isolation and hydride generation. Following removal of the copper, a 400 µl sample was injected into a water carrier stream. This was merged with hydrochloric acid and subsequently with sodium tetrahydroborate soution. After introduction of argon, the selenium hydride was separated by a glass U-tube separator and atomized by a tube-in-flame atomizer. The intermittent regeneration of the column with 1 mol dm–3 HCl enabled repeated matrix isolation without any loss in resin efficiency or the need for column repacking and gives the option for total automation. The procedure was validated through accurate analyses of two copper metal reference materials, National Institute of Standards and Technology Standard Reference Material 454 Unalloyed Copper XI and Bundesanstalt für Materialforschung und -prüfung, Germany, Certified Reference Material 361 Copper, containing 479 and 36 µg g–1 of SeIV, respectively. The system was found to have a characteristic concentration of 1.0 ng ml–1, limit of detection of 2.1 ng ml–1, relative standard deviation of 1.5%(10 ng ml–1 SeIV, n= 12) and sample throughput of 51 h–1.

Article information

Article type
Paper

J. Anal. At. Spectrom., 1991,6, 133-138

Elimination of copper interference by continuous flow matrix isolation in the determination of selenium by flow injection hydride generation atomic absorption spectrometry

S. G. Offley, N. J. Seare, J. F. Tyson and H. A. B. Kibble, J. Anal. At. Spectrom., 1991, 6, 133 DOI: 10.1039/JA9910600133

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.