Issue 8, 1988

Spectrophotometric method for the determination of total cyanide in wastewater samples

Abstract

A sensitive spectrophotometric method is described for the detection of low cyanide levels in wastewaters. Wastewaters often contain sulphide and addition of lead carbonate is the recommended method for removal of sulphide interference. However, we have found that addition of lead carbonate is unsatisfactory. The addition of a stoicheiometric amount of lead to remove the sulphide interference, this amount being determined by titration with lead acetate using a redox electrode for end-point determination, is more satisfactory. The precision and recoveries (average 91%) obtained with this modified procedure were acceptable.

Article information

Article type
Paper

Analyst, 1988,113, 1273-1276

Spectrophotometric method for the determination of total cyanide in wastewater samples

M. Drikas and B. I. Routley, Analyst, 1988, 113, 1273 DOI: 10.1039/AN9881301273

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements