Continuous colorimetric monitoring of vapour-phase urea and cyanates

Abstract

A method is described for continuously monitoring the concentrations of urea and cyanates in gases, based on a modification of a colorimetric method used for urea in human serum. The method was calibrated with standard solutions of urea and potassium cyanate. The reproducibility was ±2% throughout. Using this method, the vapour pressure of urea was measured from 58 to 113 °C. The vapour pressure results have an estimated accuracy of 10% in the range 3 × 10–4 to 5 × 10–2 mmHg.

Article information

Article type
Paper

Analyst, 1978,103, 759-765

Continuous colorimetric monitoring of vapour-phase urea and cyanates

L. E. Trimble and R. J. H. Voorhoeve, Analyst, 1978, 103, 759 DOI: 10.1039/AN9780300759

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.