Issue 1161, 1972

The determination of sulphur dioxide in meats

Abstract

Several methods were compared in determining sulphur dioxide in meat samples that contained no added sulphur dioxide but that had various pH values, in order to determine whether or not false positive results were obtained owing to the presence of hydrogen sulphide in the meat. The recovery of sulphur dioxide that had been added to meat samples was also studied.

An iodimetric method gave false positive results for sulphur dioxide. A modified Monier-Williams method did not give false positive results, but it has limited sensitivity, giving a possible error of ±6·4 p.p.m. with a 10-g sample. The relative merits of each method are discussed.

Article information

Article type
Paper

Analyst, 1972,97, 937-939

The determination of sulphur dioxide in meats

D. Barnett, Analyst, 1972, 97, 937 DOI: 10.1039/AN9729700937

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.