Issue 8, 2019

Design and evaluation of a portable PM2.5 monitor featuring a low-cost sensor in line with an active filter sampler

Abstract

Fine particulate air pollution (PM2.5) is a health hazard with numerous indoor and outdoor sources. Versatile monitors are needed to characterize PM2.5 sources, concentrations, and exposures in a range of locations and applications. Whereas low-cost light-scattering PM sensors provide real-time measurements with limited accuracy, gravimetric samples provide more accurate, albeit time-integrated, measurements. When used together, low-cost sensor data can be corrected to gravimetric samples. Here we describe the development of a portable PM2.5 monitor that features a low-cost sensor in line with an active filter sampler. Laboratory tests were conducted to determine (1) the accuracy and precision of PM2.5 concentrations derived from the filter sample and (2) correction factors for the low-cost sensor response to ammonium sulfate, Arizona road dust, urban particulate matter, and match smoke. Filter samples collected at 0.25 and 1.0 L min−1 had mean biases of −10% and −4%, relative to a tapered element oscillating microbalance, and a relative standard deviation (RSD) that ranged from 1% to 17%. The low-cost sensor correction factor varied with the test aerosol, sample flow rate, and between individual monitors. Gravimetric correction reduced the bias and RSD of ∼1 hour average concentrations measured by low-cost sensors in three collocated monitors. A week-long field experiment was also conducted to investigate how the monitor could be used to learn about sources of residential air pollution. Field data were used to identify: (1) pollution events resulting from cooking and use of a wood furnace and (2) variations in the number of air changes per hour inside the residence.

Graphical abstract: Design and evaluation of a portable PM2.5 monitor featuring a low-cost sensor in line with an active filter sampler

Supplementary files

Article information

Article type
Paper
Submitted
18 May 2019
Accepted
01 Aug 2019
First published
05 Aug 2019

Environ. Sci.: Processes Impacts, 2019,21, 1403-1415

Design and evaluation of a portable PM2.5 monitor featuring a low-cost sensor in line with an active filter sampler

J. Tryner, C. Quinn, B. C. Windom and J. Volckens, Environ. Sci.: Processes Impacts, 2019, 21, 1403 DOI: 10.1039/C9EM00234K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity