Issue 80, 2016

A biocompatible serine functionalized nanostructured zirconia based biosensing platform for non-invasive oral cancer detection

Abstract

We report results of studies relating to the fabrication of nontoxic, biocompatible serine functionalized nanostructured zirconia (serine/nZrO2) for oral cancer detection. The hydrothermally synthesized ZrO2 nanoparticles (∼4.5 nm) have been characterized using X-ray diffraction (XRD) and transmission electron microscopy (TEM). The cytotoxicity studies of serine/nZrO2 carried out using MTT assay on the HEK 293 human cell line reveal biocompatibility of the serine/nZrO2. The serine functionalized nZrO2 are electrophoretically deposited onto a hydrolysed indium tin oxide (ITO) coated glass electrode (serine/nZrO2/ITO). Furthermore, monoclonal antibodies (anti-CYFRA-21-1) were covalently immobilized onto the serine/nZrO2/ITO electrode and BSA was been used for blocking of the non-specific binding sites. The fabricated BSA/anti-CYFRA-21-1/serine/nZrO2/ITO immunoelectrode was used for label free, non-invasive and efficient detection of an oral cancer biomarker (CYFRA-21-1). The electrochemical response studies of this immunoelectrode exihibited a wider linear detection range (0.01–29 ng mL−1) with a remarkable detection limit (0.01 ng mL−1) and a quick response time (6 min) for detection of the CYFRA-21-1 antigen. The results of validation studies conducted on the fabricated immunoelectrode (BSA/anti-CYFRA-21-1/serine/nZrO2/ITO) using saliva samples of oral cancer patients indicate a good agreement with the results obtained via enzyme linked immunosorbent assay (ELISA).

Graphical abstract: A biocompatible serine functionalized nanostructured zirconia based biosensing platform for non-invasive oral cancer detection

Supplementary files

Article information

Article type
Paper
Submitted
21 Mar 2016
Accepted
29 Jul 2016
First published
08 Aug 2016

RSC Adv., 2016,6, 77037-77046

A biocompatible serine functionalized nanostructured zirconia based biosensing platform for non-invasive oral cancer detection

S. Kumar, J. G. Sharma, S. Maji and B. D. Malhotra, RSC Adv., 2016, 6, 77037 DOI: 10.1039/C6RA07392A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements