Issue 7, 2023

Development of an optimised method for measurement of iodine-129 in decommissioning wastes using ICP-MS/MS

Abstract

Accurate, low-level measurement of the long-lived fission product 129I is important for waste characterisation and long-term monitoring of waste facilities and the surrounding environment. Inductively coupled plasma mass spectrometry (ICP-MS) is well-suited to high throughput, sensitive measurement of 129I as a cost-effective alternative to other mass spectrometric and decay counting techniques. Accurate 129I measurement by ICP-MS is affected by the multiple interferences on m/z = 129, necessitating multi-stage sample preparation and/or mathematical correction. This study assesses the capabilities of tandem ICP-MS/MS for rapid and routine measurement of 129I in nuclear wastes. The advantages of the tandem setup for removal of isobaric, polyatomic and tailing interferences are demonstrated, as are the improvements in sensitivity through matrix modification and the importance of selecting an appropriate internal standard. The optimised setup was applied to measurement of various decommissioning waste simulants following direct extraction of 129I. The procedure achieved an instrument detection limit of 1.05 × 10−4 Bq g−1 (0.017 ng g−1) for 129I, which is two orders of magnitude below the target out-of-scope limit of 0.01 Bq g−1 (1.57 ng g−1), with good agreement between ICP-MS/MS and liquid scintillation counting (LSC). The results show that rapid, routine, low-level measurement of 129I is achievable by ICP-MS/MS for end users in decommissioning and environmental monitoring.

Graphical abstract: Development of an optimised method for measurement of iodine-129 in decommissioning wastes using ICP-MS/MS

Article information

Article type
Paper
Submitted
14 Feb 2023
Accepted
16 May 2023
First published
24 May 2023

J. Anal. At. Spectrom., 2023,38, 1431-1441

Development of an optimised method for measurement of iodine-129 in decommissioning wastes using ICP-MS/MS

Ž. Zacharauskas, P. Warwick, B. Russell, D. Reading and I. Croudace, J. Anal. At. Spectrom., 2023, 38, 1431 DOI: 10.1039/D3JA00045A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements