Roman A.
Barmin
a,
MirJavad
Moosavifar
a,
Rui
Zhang
a,
Stephan
Rütten
b,
Sven
Thoröe-Boveleth
c,
Elena
Rama
a,
Tarun
Ojha
a,
Fabian
Kiessling
a,
Twan
Lammers
*a and
Roger M.
Pallares
*a
aInstitute for Experimental Molecular Imaging, RWTH Aachen University Hospital, Aachen 52074, Germany. E-mail: rmoltopallar@ukaachen.de; tlammers@ukaachen.de
bElectron Microscope Facility, RWTH Aachen University Hospital, Aachen 52074, Germany
cInstitute for Occupational, Social and Environmental Medicine, RWTH Aachen University Hospital, Aachen 52074, Germany
First published on 9th February 2024
Photoacoustic (PA) imaging is an emerging diagnostic technology that combines the penetration depth of ultrasound (US) imaging and the contrast resolution of optical imaging. Although PA imaging can visualize several endogenous chromophores to obtain clinically-relevant information, multiple applications require the administration of external contrast agents. Metal phthalocyanines have strong PA properties and chemical stability, but their extreme hydrophobicity requires their encapsulation in delivery systems for biomedical applications. Hence, we developed hybrid US/PA contrast agents by encapsulating metal phthalocyanines in poly(butyl cyanoacrylate) microbubbles (PBCA MB), which display acoustic response and ability to efficiently load hydrophobic drugs. Six different metal chromophores were loaded in PBCA MB, showing greater encapsulation efficiency with higher chromophore hydrophobicity. Notably, while the US response of the MB was unaffected by the loading of the chromophores, the PA characteristics varied greatly. Among the different formulations, MB loaded with zinc and cobalt naphthalocyanines showed the strongest PA contrast, as a result of high encapsulation efficiencies and tunable optical properties. The strong US and PA contrast signals of the formulations were preserved in biological environment, as demonstrated by in vitro imaging in serum and whole blood, and ex vivo imaging in deceased mice. Taken together, these findings highlight the advantages of combining highly hydrophobic PA contrast agents and polymeric MB for the development of contrast agents for hybrid US/PA imaging, where different types of information (structural, functional, or potentially molecular) can be acquired by combining both imaging modalities.
To overcome this problem, exogenous contrast agents with higher absorption coefficients than endogenous counterparts have been developed. Some examples include organic dyes, such as indocyanine green and methylene blue, and metallic or semiconducting nanostructures.6–9 Nevertheless, organic dyes are limited by their rapid photobleaching, irreversible aggregation in aqueous media, and non-specific protein interactions in biological fluids, which can drastically disrupt their absorption spectra and reduce their PA contrast capabilities.10–12 Metallic nanoparticles, on the other hand, do not photobleach, and thus their PA signal is preserved over time. However, their tendency to accumulate in fenestrated organs, such as liver and spleen, for prolonged periods of time limits their clinical use13 and has promoted new efforts to develop formulations with improved accumulation profiles.14,15 Metal phthalocyanines (MePc), naphthalocyanines (MeNc) and their derivatives exhibit intense absorbance in the red and near-infrared regions of the spectrum, where light displays deeper tissue penetration, as well as high chemical stability, resulting in their use as PA contrast agents and sensitizers for photo-/sono-dynamic therapy.16–19 The two central hydrogen atoms of their tetrapyrrolic macrocycle can be substituted by a wide range of metal elements (including zinc, cobalt, and vanadyl), affecting chromophore absorbance and solvent solubility.20,21 However, their extreme hydrophobicity and poor solubility in aqueous solutions require their encapsulation into delivery systems.16,21–23
Micron-sized microbubbles (MB) made of poly(butyl cyanoacrylate) (PBCA) polymer can serve as effective carriers for encapsulating hydrophobic molecules.24,25 Moreover, the MB air-filled core displays acoustic responsiveness, leading to its primary use in US contrast imaging.26 The PBCA MB platform is biocompatible at diagnostic doses, and can be bioconjugated with targeting agents, expanding its use to molecular imaging and targeted drug delivery, among others.24,27,28 In a previous study, we demonstrated the good loading of hydrophobic molecules with different chemical structures, namely nile red (logP value of 3.5), coumarin 6 (logP 4.9), and pyrene (logP 6.0) in PBCA MB, and their US-induced release.29 In addition, the signal of PA agents (i.e., porphyrins and gold nanoparticles) has been recently enhanced by loading them in the shells of MB, and exploiting the radial oscillation capabilities of the latter.30–33 Therefore, we hypothesize that the high hydrophobicity of MePc and MeNc derivatives (with logP values up to 10.2) can promote their efficient encapsulation into PBCA MB shells, while their high molar extinction coefficients and tunable absorbance bands combined with the acoustic amplification provided by the MB templates can facilitate strong PA signal generation.
In this study, we developed new hybrid contrast agents for PA and US imaging by encapsulating MePc and MeNc with different chelated metals into PBCA MB. We have shown that the higher hydrophobicity of MeNc promotes higher chromophore loading into MB polymer shells compared to the moderately hydrophobic MePc. After chromophore loading, the encapsulated dyes display PA signals that are proportional to their optical properties, while the resulting PBCA MB formulations preserve their US-imaging contrast capabilities. Zinc and cobalt chelated MeNc, which show the highest levels of encapsulation into MB shells (on the order of 107 molecules/MB), provide MB with strong PA signals with the highest intensity values around 770 nm. Moreover, ex vivo studies of selected dye-loaded specimens demonstrate high PA and US contrast signals in deceased mice. Taken together, these results prove the benefits of combining highly hydrophobic PA contrast agents and polymeric MB for the development of contrast agents for hybrid imaging, which may be beneficial to extract different information, such as anatomical, functional and molecular, and for image-guided therapy.
MePc and MeNc were encapsulated into the shell of the PBCA MB following a previously described protocol.25,29 5 mg of each dye were used to ensure the maximum loading into the MB shell. The 5 mg were dissolved in 500 μL of DMSO at 50 °C. After dye dissolution, each solution was cooled down at room temperature, and mixed with 10 mL of solution containing 1010 MB. The mixtures were stirred at 50 rpm for 24 h. Once stirring was finished, the samples were left to rest overnight to allow the MB to float and form a MB cake. The aqueous solutions under each MB cake were replaced several times to remove the unencapsulated dye until no free drug was present in the solution and no precipitates were found on the vial bottom. As a result, dye-encapsulated MB were resuspended in 5 mL of storage solution.
To evaluate US-induced dye release, 0.1 mL of each dye-encapsulated MB suspension was mixed with 9.9 mL of storage solution, and sonicated for 10 min at 60 W in a US cleaner (Emmi H60, EMAG AG, Mörfelden-Walldorf, Germany) to ensure that all MB present in the sample were destroyed. Samples were then centrifuged at 4700 rpm for 10 min to allow MB shell fragments to precipitate. After precipitate removal, the aqueous solutions containing the released dyes were kept in the dark for characterization.
The intact MB samples were vigorously agitated to achieve uniform distribution of MB floated in the solution. Approximately 200 mg of each sample was then removed and accurately weighed into a microwave pressure digestion vessel, followed by the addition of internal standard (Rhodium, 1 mg L−1, Merck, Darmstadt, Germany), 2.5 mL nitric acid (Suprapur, 65%, Merck, Darmstadt, Germany), 2.5 mL hydrochloric acid (Suprapur, 32%, Merck, Darmstadt, Germany), 2.5 mL hydrogen peroxide (Suprapur, 30%, Merck, Darmstadt, Germany) and 2.5 mL DI water. The samples were then digested in the Ethos.lab microwave pressure digestion system (MLS GmbH, Leutkirch, Germany). In the program used, the samples were first heated to 210 °C within 45 min. This temperature was maintained for 15 min and then cooled to room temperature.
For aqueous solutions obtained after US-induced dye release, 1 mL was taken and mixed with 20 μL of nitric acid (Suprapur, 65%; Merck, Darmstadt, Germany) and internal standard (rhodium, 1 mg L−1; Merck, Darmstadt, Germany). The volume of the mixture was adjusted to 10 mL with DI water.
For each chromophore, the number of dye molecules encapsulated per single MB was calculated according to , where Cdye is the concentration of the encapsulated chromophore (mg mL−1), Mdye is the molecular weight of the corresponding dye (577910 mg mol−1 for ZnPc, 1002570 mg mol−1 for ZnTTBNc, 571,460 mg mol−1 for CoPc, 771690 mg mol−1 for CoNc, 579,460 mg mol−1 for VPc, and 1004120 mg mol−1 for VTTBNc, respectively), NA is the Avogadro's number, and CMB is the concentration of chromophore-encapsulated MB (number of MB mL−1).
US-induced chromophore release (%) was calculated as the ratio between the chromophore concentrations measured for the solutions containing the released dyes after MB destruction and the chromophore concentrations measured for chromophore-encapsulated MB samples.
PA imaging was performed using the Vevo® LAZR system (VisualSonics, Amsterdam, The Netherlands) that is built around the Vevo 2100 setup and equipped with the optical fiber mounted on either side of the MX 250 transducer using the fiber-holder included with the system, and the flashlamp pumped Q-switched Nd:YAG laser. To mimic in vivo vessel conditions, polyethylene tubes with the inner and the outer diameters of 0.58 and 0.96 mm, respectively (Reichelt Chemietechnik, Heidelberg, Germany), were fixed in the sample holder and filled with 20 μL of chromophore-encapsulated MB samples diluted to the concentrations of 1 × 109 MB mL−1. Before the imaging session, the sample holder was filled with DI water and set at a focus depth of 10 mm. The PA spectra were acquired from 680 nm to 920 nm with a PA gain of 45 dB in triplicate. As control groups, chromophores were dissolved in DMSO or DI water at concentrations corresponding to the loading amounts in 1 × 109 MB and imaged similarly to the procedure described above. All PA imaging experiments were performed with an imaging depth of 10 mm.
The PA signal stability of the selected MB samples was recorded at 680 nm under continuous laser pulse exposure every 200 ms for 3 min.
To investigate the behavior of chromophore-loaded MB in biological samples, in vitro PA imaging was performed in the presence of 10% FBS, 50% FBS, and 50% blood. Briefly, the MB samples were transferred to PBS and mixed with the desired amount of biological sample to achieve a MB concentration of 1 × 109 MB mL−1, followed by PA imaging as described above. The stability of the PA signal was measured at 0 min, 10 min, 30 min, 2 h, 6 h and 24 h for solutions containing FBS and at 0 min, 5 min and 10 min for solutions containing blood. For the blood PA imaging, a mixture of plain MB with a concentration of 1 × 109 MB mL−1 and 50% blood were taken as the control group. Measurements were performed in triplicate.
Prior to imaging, the mouse legs were shaved. Before intramuscular MB administration, control images were acquired using 4% acoustic power and a US gain of 8 dB for US NLC mode and a PA gain of 39 dB, wavelength range from 680 to 920 nm, for PA spectral imaging. The settings were adjusted to minimize non-specific signals that could come from the skin surface. After recording the control images, 1 × 109 MB of selected samples were injected in each leg, followed by a 50 μL saline flush, and US and PA images were recorded at nearly similar transducer positions as for the control images and similar setup settings as for controls. For each sample, 4 mouse legs were imaged before and after MB injection.
In addition, a four times lower dose of ZnTTBNc encapsulated MB (2.5 × 108 MB) was injected to evaluate the US and PA imaging capabilities at lower concentrations. US NLC and PA images were recorded following the same protocol as described before.
Fig. 1 Chemical structures and optical properties of metal phthalocyanines and naphthalocyanines. (a) Commercially available phthalocyanines chelated with zinc(II), cobalt(II) and vanadyl(IV) (referred to as ZnPc, CoPc and VPc, respectively), cobalt(II) naphthalocyanine (CoNc), and tetra-tert-butyl-2,3-naphthalocyanines chelated with zinc(II) and vanadyl(IV) (ZnTTBNc and VTTBNc, respectively) were selected based on their high hydrophobicity (logP) values, which primarily depend on the chromophore structure. Variations in the chelated metals (zinc, cobalt, vanadyl) tune the optical properties of the complex. (b) Absorption spectra, and (c) fluorescence emission spectra of the different chromophores in DMSO. Fluorescence spectra were recorded upon excitation at 640 nm. Literature values of maximum absorption wavelengths, molar absorption coefficients, and fluorescence quantum yields of the chromophores are listed in Table S1 (ESI†). Absorption spectra of the chromophores in DI water, and fluorescence emission spectra of the chromophores in DMSO upon excitation at their maximum absorption wavelengths are shown in Fig. S1 (ESI†). |
Once the optical characteristics of the different chromophores were characterized, we tested their loading into PBCA MB shells. Based on our previous experience with hydrophobic molecules, we hypothesized that those chromophores with higher logP values would display higher loading efficiencies. The different MePc and MeNc chromophores were encapsulated in PBCA MB shells using a post-loading procedure. Fig. 2(a) shows the MB diameter distribution profiles of chromophore-encapsulated MB and plain PBCA MB (labeled as Plain MB), and demonstrates that the MB mean diameter was not affected by the loading procedure. The MB mean diameter was around 2.3 μm, which was consistent with our previous studies.25,35 The narrow diameter distributions of the MB samples were additionally confirmed by wide-area OM (Fig. S2, ESI†). Fig. 2(a) also shows a decrease in MB concentration after encapsulation, which can be attributed to the multiple washing steps associated with the post-loading procedure. Moreover, all MB samples showed similar shell thickness values, around 50 nm (Fig. 2(b)). Corresponding cryoSEM images of plain MB and dye-encapsulated MB further corroborated that the loading process did not affect the MB diameter and morphology, as observed in Fig. 2(c) and Fig. S3 (ESI†). Absorption (extinction) spectra of MB samples showed high turbidity (i.e., strong light scattering) by the micron-sized templates (Fig. S4, ESI†), which was consistent with previous reports.46,47 Taken together, these results indicate that MePc and MeNc encapsulation does not affect the MB diameter distribution and shell thickness parameters. This is important, since variations in MB size and shell characteristics may alter (or even hamper) the MB acoustic properties.35,48
Fig. 2 Metal phthalocyanine and naphthalocyanine encapsulation into PBCA MB. (a) Concentrations and diameter distributions of intact MB (Plain MB) and MB encapsulated with different chromophores (ZnPc MB, ZnTTBNc MB, CoPc MB, CoNc MB, VPc MB, and VTTBNc MB). (b) Shell thickness measurements of intact and chromophore-encapsulated MB by cryoSEM images. (c) Representative cryoSEM images of MB samples. (d) Chromophore encapsulation into MB shells as number of dye molecules loaded per one MB (Ndye/MB). (e) US-induced chromophore release (%) from MB templates. ns indicates groups that are not significantly different with p > 0.05 (one-way ANOVA with post hoc Tukey HSD test). Representative wide-area OM and cryoSEM images, absorption spectra of MB samples, and chromophore loading per 1 × 109 MB are presented in Fig. S2–S4 and Table S2 (ESI†), respectively. |
The efficiency of dye encapsulation dictates the PA contrast capabilities of the resulting platform, as higher levels of chromophores encapsulated in the MB shell are likely to provide stronger optical properties. Fig. 2(d) shows the values of dye molecules encapsulated per single MB (Ndye/MB) for each sample, and Table S2 (ESI†) provides chromophore loading amounts per 1 × 109 MB. The encapsulation values were proportional to the logP values of the molecules, with more hydrophobic MeNc chromophores displaying higher loading. When comparing encapsulation levels of MeNc or MePc, zinc(II) chelated dyes were more efficiently encapsulated than cobalt(II) chelated dyes, while vanadyl(IV) containing dyes showed the lowest encapsulation. Although these observations are likely caused by multiple factors, we hypothesize that the stable dimerization of vanadyl(IV) chelated chromophores with the formation of strong interplanar vanadyl–vanadyl or vanadyl–nitrogen bonds may have contributed to its lower loading in PBCA MB shells, as larger dye dimers may be harder to encapsulate than monomer chromophores. This hypothesis is consistent with the lower dimerization constants of ZnPc and CoPc compared to those of VPc.49,50 Overall, ZnTTBNc and CoNc showed the highest encapsulation rates with values of 2.2 ± 0.1 × 107 and 1.4 ± 0.1 × 107 dye molecules per MB, respectively, which corresponds to values of 22.0 ± 1.1 and 13.3 ± 0.7 μg of dye molecules/1 × 109 MB, respectively. Notably, although the encapsulation levels were rather different between samples, all MB showed a similar percentage of chromophore release upon US exposure, as exemplified in Fig. 2(e).
Fig. 3(d) shows combined US bright (B)-mode and PA images of MePc and MeNc encapsulated MB (and DI water and Plain MB taken as controls) obtained with the Vevo LAZR system at a wavelength of 680 nm and MB concentration of 1 × 109 MB mL−1 in a vessel-like phantoms. While DI water and plain MB did not provide PA signal, all chromophore-encapsulated MB displayed PA signal, which varied among the different chromophore formulations. The PA spectra were recorded from 680 to 900 nm to characterize the PA response of the samples (Fig. 3(e)). Among the MB samples, ZnTTBNc MB displayed the highest PA intensity within the recorded wavelength range, with a PA signal intensity of 4.1 ± 0.3 at 680 nm (Fig. 3(f)), which was caused by the chromophore strong absorption band in the near-infrared region of the spectrum (centered at 764 nm) and its high hydrophobicity (logP value of 10.2) that resulted in high encapsulation values. Interestingly, CoNc MB displayed moderate PA signal, with an intensity of 0.6 ± 0.2 at 680 nm (Fig. 3(f)). Its highest PA signal was 0.9 ± 0.2 at 770 nm, despite having relatively low (compared to other chromophores) absorption in the red and near-infrared region of the spectrum. Its PA response was driven by the high hydrophobicity of the chromophore (logP value of 8.7), which yielded a high encapsulation efficiency. ZnPc MB also showed moderate PA response with a signal intensity of 1.4 ± 0.3 at 680 nm, which was likely caused by the balance between the strong absorbance of the chromophore and its relatively low hydrophobicity (logP value of 4.4) compared to MeNc, which resulted in moderate encapsulation levels. Despite the relatively poor encapsulation level of VTTBNc compared to other MeNc, its strong absorption near 800 nm promoted the weak but measurable PA signal intensity of VTTBNc MB over the spectral range. Considering the US and PA capabilities demonstrated by ZnTTBNc MB, CoNc MB and ZnPc MB, these three formulations were selected for further characterization.
Next, we compared the PA performances of the selected MB formulations and the free chromophores dissolved in either DMSO or DI water. ZnTTBNc MB, CoNc MB and ZnPc MB samples showed higher PA signal intensities than the free chromophore counterparts in water, as shown in Fig. 4. We hypothesize that the MB formulations performed better because of two factors. First, the MePc and MeNc loaded inside the shell were protected from water-induced aggregation and PA signal quenching. Second, the oscillations produced by the MB shell might have synergized with the thermoelastic expansion of the chromophores, improving the PA performances of the chromophore-loaded MB samples. This synergistic effect has been recently reported in other formulations, such as MB loaded with porphyrin dyes and gold nanoparticles.30–32 While chromophores dissolved in DMSO could yield higher PA intensities around their maximum absorption bands, dye-loaded MB could exceed the PA performances of the chromophores over a wider range of wavelengths. These bandwidth increases may be related to the local aggregation of the dyes in the shells during the loading procedure (similar to a previous report18). However, these potential local aggregations did not quench the PA responses and provided wider PA responses over multiple wavelengths, which combined with the water solubility of the MB formulations yielded highly performing PA probes. In addition, all selected MB samples preserved PA stability over longer exposure times (3 min) as shown in Fig. S6 (ESI†).
Fig. 4 Comparison of PA performance of chromophore-encapsulated MB versus chromophores dissolved in DMSO and DI water at equal concentrations in phantoms. (a) ZnTTBNc-, (b) CoNc-, and (c) ZnPc-containing samples were adjusted to the concentrations presented in Table S2 (ESI†), and PA intensities were recorded in a wavelength range from 680 to 900 nm. |
Furthermore, although the PA bands of the selected MB samples were broad, they showed a significant PA contrast signal at multiple frequencies in the red and near-infrared spectral regions, which can be distinguished from numerous endogenous and clinically relevant PA chromophores, including oxy- and deoxy-hemoglobin, and collagen.1,6,51 Therefore, the described probes could be potentially used for multispectral PA imaging, where the tissue of interest is illuminated with a set of excitation wavelengths relevant to each specific (endogenous or exogenous) chromophore.
Next, the colloidal and PA signal stability of selected MB samples was evaluated in biological fluids, i.e., in solutions containing 10% and 50% FBS (Fig. S7 and S8, ESI† respectively). When ZnTTBNc MB were transferred to PBS and mixed with 10% FBS, the diameter distribution of the samples remained unchanged (Fig. S7a, ESI†), preserving the mean diameter around 2.3 μm over 24 h (Fig. S7b, ESI†). The stability of the MB also yielded strong PA signals up to 24 h, as shown in the PA intensity spectra (Fig. S7c, ESI†) and the mean PA signal intensity at 770 nm (Fig. S7d, ESI†). Similar patterns of preserved colloidal and PA signal stability were observed for CoNc MB and ZnPc MB as shown in Fig. S7e–h and i–l (ESI†), respectively. When the FBS concentration was increased to 50%, the mean diameter of the MB samples remained intact for 30 min, while the diameter slightly decreased at the 2 h time point and then remained stable up to 24 h, as shown in Fig. S8a, e, and i (ESI†) for ZnTTBNc MB, CoNc MB, and ZnPc MB, respectively. We hypothesize that this was caused by the potential stiffening of the MB shell during the protein corona formation, leading to partial dissolution of the MB gaseous core to equilibrate the osmotic pressure with the Laplace pressure of the MB. This is in agreement with previous reports on MB dissolution models.52–54 However, such decreases in mean diameter were not statistically significant, as demonstrated in Fig. S8b, f, and j (ESI†), for ZnTTBNc MB, CoNc MB, and ZnPc MB, respectively. Hence, the stability and strong PA signal of chromophore-encapsulated MB were preserved over 24 h.
When the MB samples were dispersed in the 50% blood solution, their strong PA contrast signals were clearly distinguishable from the control, as shown in Fig. 5(a)–(c) for ZnTTBNc MB, CoNc MB, and ZnPc MB, respectively. The MB contrast signal remained stable over the tested time (up to 10 min), as shown by the PA signal intensities at the characteristic PA bands of ZnTTBNc, CoNc, and ZnPc (i.e., 770, 780, and 680 nm, respectively) compared to the control (Fig. 5(d)–(f), respectively). The testing time in blood was selected based on the in vivo circulation time of PBCA MB after systemic administration, which is inferior to 10 min.36 Taken together, the MB samples retained colloidal stability and strong PA signals that were clearly distinguishable from the background of the biofluids.
Lastly, since the NLC and PA intensities were very intense for the ZnTTBNc MB, we measured whether their concentration could be reduced by a factor of 4 (i.e., to 2.5 × 108 MB) and still display strong responses in both US and PA imaging modalities. At those low concentrations, ZnTTBNc displayed high intensities both in US NLC and PA images (Fig. S9a, ESI†), with NLC intensity as high as 1332 ± 34 c.u. after MB injection compared to 110 ± 8 c.u. of the control (Fig. S9b, ESI†), and PA intensities of 0.65 and 0.87 at 680 nm and 770 nm (Fig. S9c, ESI†), respectively, which exceeded the intensities of CoNc MB and ZnPc MB samples at four times higher concentrations.
Taken together, the results presented in this study demonstrate that the capabilities of PBCA MB can be further expanded by loading their shell with metal phthalocyanines. The resulting formulation show both US and PA imaging characteristics, which may provide new avenues to acquire diagnostic and therapeutic information. We envision the multifunctional contrast agents being used in different ways, including discerning the response of intact PBCA MB (US) and the release of cargo (PA) upon irradiation with US destructive pulses. Moreover, if metal phthalocyanines were combined with other chromophores with different spectral characteristics, multiplexing imaging could be developed, where several MB formulations loaded with different chromophores and functionalized with distinct targeting agents could be used to simultaneously differentiate multiple vascular biomarkers.
PA | Photoacoustic |
US | Ultrasound |
MB | Microbubbles |
PBCA | Poly(butyl cyanoacrylate) |
MePc | Metal phthalocyanines |
MeNc | Metal naphthalocyanines |
ZnPc | Zinc(II) phthalocyanine |
ZnTTBNc | Zinc(II) 2,11,20,29-tetra-tert-butyl-2,3-naphthalocyanine |
CoPc | Cobalt(II) phthalocyanine (CoPc) |
CoNc | Cobalt(II) 2,3-naphthalocyanine |
VPc | Vanadyl(IV) phthalocyanine (VPc) |
VTTBNc | Vanadyl(IV) tetra-tert-butyl-2,3-naphthalocyanine (VTTBNc) |
NLC | Non-linear contrast. |
Footnote |
† Electronic supplementary information (ESI) available: Literature values of maximum absorption wavelengths, molar absorption coefficients, and fluorescence quantum yields of selected chromophores; optical properties of metal phthalocyanines and naphthalocyanines in DI water and DMSO; representative wide-area OM micrographs of MB samples; representative wide-area cryoSEM micrographs of MB samples; absorption (extinction) spectra of MB samples; chromophore loading per 1 × 109 MB; PA intensity spectra of the different chromophores dissolved in DMSO at the same amounts as loaded per 1 × 109 MB; PA signal stability of MB over time recorded at 680 nm; colloidal and PA signal stability of chromophore-encapsulated MB in 10% FBS solution; colloidal and PA signal stability of chromophore-encapsulated MB in 50% FBS solution; PA signal stability in 50% blood solution; ex vivo US/PA imaging at low ZnTTBNc MB concentration (PDF). See DOI: https://doi.org/10.1039/d3tb02950f |
This journal is © The Royal Society of Chemistry 2024 |