Robert D.
Crapnell
and
Craig E.
Banks
*
Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, UK. E-mail: c.banks@mmu.ac.uk; Tel: +44 (0)1612471196
First published on 11th March 2021
When you bite into a chile pepper or eat food containing chile (chilli), one might feel heat, or other associated feelings, some good such as the release of endorphins, and some bad. The heat, or pungency, and related feelings from eating chile peppers are the result of their chemical composition, i.e. the concentrations of capsaicinoids. The major components are capsaicin and dihydrocapsaicin, which occur in chiles in the ratio of 6:4. Other capsaicinoids occur in smaller concentrations and are known as the “minor” capsaicinoids. Wilbur L. Scoville in 1912 created an organoleptic test, now known as the Scoville scale, which asked a panel of tasters to state when an increasingly dilute solution of the chile pepper in alcohol no longer burned the mouth. Following the Scoville scale, a plethora of analytical techniques later followed. In this overview, we explore the endeavours directed to the development of electrochemical-based sensors for the determination of capsaicin and related compounds, starting from their use in hyphenated laboratory set-ups to their modern use as stand-alone electroanalytical sensors. The latter have the advantage of providing a rapid and sensitive methodology that has the potential to be translated in the field; future trends and issues to be overcome are consequently suggested.
The original method to determine the pungency of a chile pepper is the Scoville Organoleptic Test.6 In this approach, 1 grain† of ground up chile pepper was dissolved into ethanol and left overnight, following which, it was shaken, filtered and then diluted with sweetened water.‡ A panel of five testers would then taste the chile solution and, via serial dilution, continue testing until the pungency was undetectable. If the tester panel could barely detect any heat in a mixture of 1 part of the alcohol solution in 50000 parts of sweetened water, the chile pepper is rated at 50000 Scoville heat units (SHU). This method measures the total capsaicinoid concentration and of course is subjective and depends upon a taster's palate and sensitivity to capsaicinoids, and has clear limitations on throughput and (substantial) serial dilution for hot chile peppers. Note that once exposed repeatedly to capsaicin, the receptors in the mouth that register heat are depleted; this enables eaters to eat hotter and hotter food. However, this would mean every time a person repeated the test their results would indicate a weakening of the same chile. That said, with its limitations, it is a useful approach to effectively benchmark and rank the hotness of chile peppers. Interested readers are directed to ref. 7 for a full biography of Wilbur L. Scoville; a more light hearted recognition honouring Scoville's work are the Scoville™ awards.8
The actual pungency of any chile pepper can vary greatly depending on many factors, such as environment, soil, temperature, weather, seed lineage, water and so on. There are five general levels of pungency classified using SHU: non-pungent (0–700 SHU), mildly pungent (700–3000 SHU), moderately pungent (3000–25000 SHU), highly pungent (25000–80000 SHU) and very highly pungent (>80000 SHU).9 Interestingly, the high end of the scale can increase significantly from 80000 SHU – The Guinness Book of World Records reports that the hottest chilli pepper is Smokin Ed's ‘Carolina Reaper’, grown by Ed Currie of PuckerButt Pepper Company (USA), which rates at an average of 1641183 SHU, held at the time of writing this, since 2017.10 A word of caution, while chile features in many eating competitions and in programs such as Man vs. Food and others, a man was hospitalised after attempting to eat one Carolina Reaper during a chile pepper eating competition in the USA.11 This person developed intense neck and head pain including thunderclap headaches with several arteries constricting, and was diagnosed with reversible cerebral vasoconstriction syndrome; the first recorded time this has been diagnosed after eating chile peppers.11 The impact of Capsicum and chile peppers is so great that there is an institute established at New Mexico State University, USA, The Chile Pepper Institute.§ Established in 1992, the institute is the only international, non-profit organization devoted to education and research related to Capsicum or chile peppers and hosts the world's foremost research-based resource centre for chile pepper information.
In addition to being the main component of chile peppers, capsaicin is reported to possess chemopreventive, antioxidant, anti-bacterial, anti-inflammatory and hypolipidemic effects.12–17 Consequently, capsaicin finds use in a range of pharmaceuticals, drug delivery and medical applications such as inclusion in topical creams, liquids and patch preparations for chronic pain syndromes, dietary supplements to tackle obesity and defensive sprays.18–23 As such, there is an analytical interest to measure capsaicinoids in a wide range of samples. That said, the majority, if not all, have appeared to have been explored for the sensing of capsaicinoids in chile peppers and chilli products; it is this that we next explore.
Sticher and co-workers appear to have been the first to report the use of HPLC-UV for the quantitative determination of capsaicin, dihydrocapsaicin, nordihydrocapsaicin and homodihydrocapsaicin in natural capsaicinoid mixtures of Capsicum fruits in 1978.26 Woodbury27 was the first to develop HPLC with spectrofluorescence to determine capsaicin in a range of chile samples (paprikas, chile peppers, and red peppers). This methodology was found to be sensitive to 2 ppm (∼32 SHU) depending on the pungency level, and it was possible to analyse 20–50 samples in 8 hours. Both methods26,27 provide substantial improvements over the Scoville Organoleptic Test. To convert from analytical units, such as ppm capsaicin, to SHU, multiply by 16, because pure capsaicin measures 16 million Scoville units (an older convention multiplied by 15 but the former should be used). Woodbury,27 importantly, was the first to demonstrate a good correlation (coefficient of 0.98) between the concentration determined byHPLC method with that determined organoleptically.27 These analytical approaches have of course been naturally extended to a range of other analytical techniques such as ultra-fast liquid chromatography,28 gas chromatography-mass spectrometry,29,30 liquid chromatography-mass spectrometry,31 and liquid chromatography-electrospray ionization/time-of-flight mass spectrometry2 to name just a few. As noted above, the SHU of a chile pepper can greatly vary due to external environmental conditions, meaning that the SHU value of a chile pepper can vary between a crop and a plant. Hence, rapid analytical approaches are required to provide accurate SHU values. We note that da Silva Antonio and co-workers have elegantly reviewed the evolution of analytical methods for capsaicinoid analysis, providing a summary of the pros and cons of the various approaches.32 In this review, we focus predominantly on electrochemical-based sensors due to their rapid, accurate analysis and portability clearly making them, by far, the best option with potential to provide an in-the-field sensing approach for the pungency determination (SHU) of chile and chilli products; therefore this is the sole focus of this overview.
Electrode | Method of detection | Analyte | Linear range | Limit of detection | Sample medium | Ref. |
---|---|---|---|---|---|---|
GC: glassy carbon; MECC-UV/EC: micellar electrokinetic capillary chromatography-UV and electrochemical detection; FI-EC: flow injection-electrochemical detection HPLC-EC: high performance liquid chromatography-electrochemical detection; ND: not determined; *: simultaneous determination; 1: minimum detectible quantities (MDQ); BPPG: basal plane pyrolytic graphite electrode; AdsSV: adsorptive stripping voltammetry; CB: carbon black; GNP: graphene nanoplatelets; DPV: Differential pulse voltammetry; CV: cyclic voltammetry; SWV: square-wave voltammetry; PIGE: paraffin-impregnated graphite electrode; 2: method involves capsaicin micro-particles mechanically attached to the PIGE; 3: LOQ; HRP: horseradish peroxidase; NG: nanographite; SPEs: screen-printed electrodes; LSV: linear sweep voltammetry; NP: nanoparticle; CNTs; carbon nanotubes; PANI: polyaniline; MIPs: molecularly imprinted polymers; EDI: electrochemically driven intercalation process; BDD: boron-doped diamond; B2-CNT-SPEs: back-to-back carbon nanotube screen-printed electrodes; PGA: poly(gallic acid); IL: ionic liquid; PSS: poly(sodium 4-styrenesulfonate); Grp: graphite; rGO: reduced graphene oxide; GEC: graphite epoxy composite electrode; PDDA: poly dimethyl diallyl ammonium chloride; pHEMA: poly(2-hydroxyethyl methacrylate); ePAD: disposable electrochemical paper-based analytical device; GrNPs: N-doped graphene nanoplatelets; CD: carbon dots; ITO: indium tin oxide electrode; CPE: carbon paste electrode; NH2-FMS: amino-functionalized mesoporous silica; PAL: phenylalanine ammonia-lyase; CCSWV: coarse cyclic square-wave voltammetry; N-MC: nitrogen-doped mesoporous carbon; CD: cyclodextrins; ExSV: ex situ extractive stripping voltammetry. | ||||||
GC | HPLC-EC (+750 mV vs. Ag/AgCl) | Capsaicin, dihydrocapsaicin* | 0.25–20 ng | 12 pg (39 fmol) | Rat plasma | 33 |
Carbon electrode (33 μm and 10 μm diameter) | MECC-UV/EC (+0.9 V vs. Ag/AgCl) | Capsaicin dihydrocapsaicin* | ND | 1631 & 821 femtomoles | ND | 34 |
GC | FI-EC (+0.5 V vs. Ag/AgCl) | Capsaicin | ND | ND | Red, yellow and green bell pepper | 35 |
Carbon paste (2.5 mm diameter) | HPLC-EC (+750 mV vs. Ag/AgCl) | Capsaicin | 31.3–500 μg mL1 | 305 ng mL1 | Takanotsume; Cecei Fellallo; Novoselska kapie; Bogyiszloi Vastaghusu; Jubila | 61 |
Porous carbon | LC with coulometric detection | Capsaicin, dihydrocapsaicin nordihydrocapsaicin* | 0.05–100 ng | 10 pg | Red pepper powder, green, blue and red pepper, habanero, bibinba, chillsouce, karamiso, toubanjan, Tabasco | 79 |
Graphite | HPLC-ECD (+450 mV vs. Pd) | Capsaicin, dihydrocapsaicin, nordihydrocapsaicin, homocapsaicin* | ND | ND | Immature (green), and mature (orange) chile peppers | 80 |
GC | FI dual electrode (+1.0 V/0.0 V vs. Ag/AgCl) | Capsaicin, dihydrocapsaicin* | 1–200 μM | 1.5 μM3 | 23 chile peppers analysed | 39 |
MWCNT-BPPG electrode | AdsSV | Capsaicin | 0.5–15 μM & 15–60 μM | 0.31 μM | Tabasco green pepper sauce, Tabasco pepper sauce, Tabasco habanero sauce, Da’ Bomb Ground Zero, Blair's 2 AM Reserve, Mad Dog's Revenge | 40 |
MWCNT-SPE | AdsSV | Capsaicin | 0.5–35 μM | 0.45 μM | Tabasco habanero, Mad Dog's Revenge | 40 |
BDD | AdsSV | Capsaicin | 0.16–20 μM | 0.034 μM | Red pepper flakes, hot pepper paste | 56 |
NH2-FMS-CPE | LSV | Capsaicin | 0.04–0.40 μM | 0.02 μM | Chile peppers | 81 |
SWCNT-SPEs | CV | Capsaicin | 0–15 μM | 0.91 μM | Habanero peppers, scotch bonnet peppers, Dutch chile, Tabasco sauce | 41 |
Pencil graphite electrode | AdsSV | Capsaicin | 16–320 nM | 3.7 nM | Red pepper and Isot pepper flakes | 69 |
Dihydrocapsaicin | 3.3–330 nM | 0.9 nM | ||||
SWCNT-SPEs | CV | Capsaicin | 5–50 μM | 0.9 μM | ND | 43 |
HRP/Fc/pHEMA-SPE | Amperometric | Capsaicin | 2.5–99.0 μM | 1.94 μM | Chile peppers | 74 |
GC | CV | Capsaicin | 53–1060 μM | 6.4 μM | Black pepper | 82 |
Au NP MWCNT-GC | DPV | Capsaicin | 0.15–35.0 μM | 0.3 μM | Chile peppers | 44 |
Mesoporous cellular foams | DPV | Capsaicin | 0.76–11.65 μM | 0.08 μM | Chile pepper, cayenne pepper, bell pepper | 73 |
B2-SWCNT-SPEs | CV | Capsaicin | 25–50 μM | 0.18 μM | ND | 42 |
GC | CV | Capsaicin | 0.1–10 mM | ND | Bird's eye chillies, Ultra Death Chilli sauce | 64 |
PIGE2 | SWV | Capsaicin | ND | ND | Bhut Jolokia, Red Savina, Fatalli, Habanero Orange, Carolina Cayenne, Cayenne, Jalapeño, Ancho and Hungarian peppers | 59 |
Graphite pencil electrodes | CV | Capsaicin | 0.1–100 μM | 100 nM | Chili powder | 83 |
Graphene–titania–Nafion™ GC | LSV | Capsaicin | 0.03–10 μM | 8.6 nM | Chungyang pepper, red pepper flakes | 55 |
GC | SWV | Capsaicin | ND | ND | Vezena luta, feferona, bombona, aiseff f1, dzinki, hybrid 13515, piran, kurtovska kapija chili peppers | 84 |
PAL/Nafion™/MWCNTs/Pt | DPV | Capsaicin | 20–100 μM | 0.6 nM | Chile peppers | 45 |
RuNP-CNTs-GC | SWV | Capsaicin | 10–410 nM | 2.5 nM | Isot, Urfa red pepper paste, Antep red pepper paste, Hatay red pepper paste | 46 |
Ag/Ag2O-PSS-rGO SPE | DPV | Capsaicin | 1.0–60 μM | 0.40 μM | Red pepper, green pepper, Capsicum frutescens | 51 |
PSS-Grp-SPE | DPV | Capsaicin | 0.3–70 μM | 0.1 μM | Pod pepper, paprika | 85 |
PANI-Pt electrode | Amperometry | Capsaicin | 34–215 μM | 0.8 μM | ND | 86 |
HRP-NG-SPEs | Chronoamperometry | Capsaicin | 0.75–24.94 μM | 0.39 μM | Chili fruit sample | 63 |
Unmodified BPPG electrode | AdsSV | Capsaicin | 0.5–10 μM | 0.24 μM | ND | 47 |
Drop-casted MWCNT-BPPG electrode | AdsSV | Capsaicin | 0.5–60 μM | 0.17 μM | ND | 47 |
Drop-casted CB-BPPG electrode | AdsSV | Capsaicin | 0.5–40 μM | 0.19 μM | ND | 47 |
Drop-casted GNP-BPPG electrode | AdsSV | Capsaicin | ND | ND | ND | 47 |
Carbon SPEs | AdsSV | Capsaicin | 0.5–30 μM | 0.20 μM | ND | 47 |
MWCNTs-SPEs | AdsSV | Capsaicin | 0.5–20 μM | 0.41 μM | ND | 47 |
Carbon paste electrode | AdsSV | Capsaicin | 0.5–50 μM | 0.40 μM | ND | 47 |
MnSe NP modified GC | DPV | Capsaicin | 5–128 μM | 0.05 μM | Black pepper | 87 |
CD-CPE | SWV | Capsaicin | 1.3–9.3 μM | 0.21 μM | Tabasco sauce | 71 |
Dihydrocapsaicin | 0.69–6.7 μM | 0.30 μM | ||||
EDI-SPEs | LSV | Capsaicin | 5–100 μM | 2.77 μM | Tabasco sauce | 88 |
N-MC GC | LSV | Capsaicin | 1–10 μM | 0.46 μM | Bird's eye red chili, bird's eye green chili, green chili, red chili, sweet green pepper, sweet red pepper, sweet orange pepper, sweet dark green pepper | 68 |
Y2O3 modified graphite paste electrode | DPV | Capsaicin | 1–80 μM | ND | ND | 89 |
IL-graphene-Nafion™-GC | LSV | Capsaicin | 0.03–10 μM | 3.2 nM | Chungyang peppers | 53 |
PGA/MWCNT/GC | DPV | Capsaicin | 0.01–1.0 μM | 2.9 nM | Red hot peppers | 48 |
Dihydrocapsaicin | 0.025–0.75 μM | 539 nM | ||||
Nonivamide | 0.05–5.0 μM | 6.1 nM | ||||
PDDA–rGO/Pd/GC | CV | Capsaicin | 0.32–64 μM | 0.10 μM | Chile peppers | 67 |
SPE | DPV | Capsaicin | 0.16–16.37 μM | 0.05 μM | Meiren chilli pepper, Chaotian green chilli pepper, Chaotian red chilli pepper, Xiaomi green chilli pepper, Xiaomi red chilli pepper | 70 |
SPE | CCSWV | Capsaicin | 1.98–5000 μM | 1.98 μM | Tabasco Chipotle, Tabasco Pepper and Tabasco Habanero | 78 |
Paper-based screen-printed bulk modified with carbon black | DPV | Capsaicin | 0.08–6 μM | 0.03 μM | Tabasco sauce, black pepper and red pepper powder | 62 |
MWCNTs-MIPs GC | DPV | Capsaicin | 0.05–100 μM | 0.02 μM | Gutter oil | 49 |
Sn-rGO SPE | CV | Capsaicin | 0.2–22 μM | 0.005 μM | Karen chili, bird's eye chili and chili sauces | 52 |
GC | DPV | Capsaicin | 0.66–20.9 μM | 0.198 μM | Cubana red pepper | 72 |
TiO2 NP GEC | CV | Capsaicin | 6–75 μM | 5.34 μM | Delhuerto hot pepper sauce, Tabasco habanero pepper sauce | 90 |
CeO2-surfactant-SWCNTs-GC | DPV | Capsaicin | 0.10–7.5 μM | 28 nM | Red hot pepper | 50 |
GrNPs ePAD | AdsSV | Capsaicin | 1–100 μM | 0.37 μM | Dried chile samples | 54 |
Phospholipid modified GC | ExSV | Capsaicin, dihydrocapsaicin | 3–60 mg L−1, 9.3–60 mg L−1 | 2.1 mg L−1, 9.3 mg L−1 | Foxta, Madras Chilli, Habanero, Carolina Reaper, bird's eye, Bhut Jolokia, Naga Jolokia extract, Habanero extract | 60 |
CD-ITO | CV | Capsaicin | 0.05–500 μM | 5.4 nM | Cayenne pepper (powder), Tabasco sauce, Thai chilli sauce | 57 |
The electrochemical detection of capsaicinoids can be traced back to the robust approach of using HPLC with electrochemical detection (HPLC-EC) as initially reported by Kawada and co-workers.33 Using an electrochemical detector with a glassy carbon electrode, the authors explored the effect of current (analytical signal) upon the applied electrochemical potential from +0.5 V to +0.9 V (vs. Ag/AgCl) for the electrochemical oxidation of capsaicin and dihydrocapsaicin at pH 5.0. A tentative electrochemical oxidation mechanism was suggested involving the loss of CH3OH and 2 protons and 2 electrons.33 A potential of +0.75 V (vs. Ag/AgCl) was chosen as the optimal oxidation potential as a compromise between maximum current response and minimum background current. The detection limits for both capsaicin and dihydrocapsaicin were reported to be 12 pg (39 fmol) and the biological half-life of capsaicin in a rat was investigated. This paper is pivotal as it demonstrates the basis of using electrochemistry as an analytical approach towards the detection of capsaicinoids. Khaled and co-workers34 applied micellar electrokinetic capillary chromatography with carbon microelectrodes for the optimised separation of capsaicin and dihydrocapsaicin (as well as homovanillic acid and hydroquinone) at pH 6.2 with femtomolar levels readily detectable. Buratti et al.35 reported the use of a flow injection system with an electrochemical detector utilising a glassy carbon working electrode operating amperometrically (potential: +0.5 V vs. Ag/AgCl) and determined capsaicin in red, yellow and green bell peppers. The authors noted that up to 60 samples per hour could be analysed, suggesting the direct, rapid and reliable monitoring of capsaicin that makes the flow system an attractive alternative over other reported methods.35
Building upon the work on HPLC-EC, flow injection analysis (FIA) with electrochemical detection has been explored for the sensing of capsaicinoids (see Table 1). There are many advantages of FIA over HPLC (see ref. 36 for a full overview) but, predominantly, it has the aim of analysing the maximum number of samples using the minimum amount of time, reagent and sample solution, whilst maintaining a low cost with a high reproducibility.36 In terms of the advantages of electroanalysis using FIA, the transport of samples to the detector is fast (convective mass transport) and as such the contact time between the sample and the electrode is reduced, potentially minimising any (detrimental) adsorption effects.37,38 Dejmkova et al.39 reported the use of flow injection analysis with amperometric dual electrochemical detection (FIA-DED) using a thin layer cell and glassy carbon working electrodes for the simultaneous sensing of capsaicin and dihydrocapsaicin. The operating potentials were explored and optimised with the study comparing FIA-DED with HPLC-DED for 23 samples of chile peppers ranging from mild to very pungent. The authors reported that for small capsaicinoid contents, even HPLC-DED determination did not provide satisfactory results, as its standard deviation was comparable to the measurement value.39 As shown in Fig. 1A, the authors examined the correlation between HPLC-DED and FIA-DED results where a tight correlation was observed, but noted that the value of the intercept suggests the tendency to overestimate the real SHU values,39 especially at low SHU levels. The authors reported that FIA-DED offers accurate results, as validated by HPLC-DED, for pepper samples of pungencies over approx. 50000 SHU, i.e. medium to high level of capsaicinoids.39 Clearly, impurities (both electroactive and non-electroactive) in the sample matrix contribute, which is likely to be overcome at high SHU levels due to more sample dilution being required. More rigorous sample pre-treatment will be required to provide accurate results at low SHU levels (i.e. below 50000 SHU).
Fig. 1 (A) Schematic image of flow injection analysis with amperometric dual electrode detection using a thin layer cell with glassy carbon working electrodes. The correlation of SHU determined by HPLC-DED and by FIA-DED using E1 (upstream electrode, EDET = 1.0 V; squares) and E2 (downstream electrode, EDET = 0.0 V; circles) for electrochemical detection is also shown.39 Reproduced with permission from ref. 39. Copyright Elsevier 2018. |
Fig. 2 (A) The first (dotted lines) and second (solid line) scans for the AdsSV of 100 μM capsaicin on the MWCNT-BPPGE in a 0.05 M Britton–Robinson buffer solution at pH 1.0, after 1 min accumulation in open circuit conditions; scan rate: 100 mV s−1. (B) Proposed electrochemical mechanism for the electrochemical oxidation/reduction of capsaicin. (C) Measured value of capsaicin concentration in ppm (electrochemically detected ppm) versus the average Scoville units for six hot pepper sauces. Inset: log of the electrochemically detected ppm versus log of the average Scoville units for six hot pepper sauces. Scheme and images reproduced with permission from ref. 40. Copyright Royal Society of Chemistry 2008.40 |
From this initial paper by Kachoosangi et al.40 a plethora of electrochemical based approaches have been explored, (see Table 1) with many extending the observations of using carbon based materials to maximise the adsorption of capsaicin, using single-walled and multi-walled carbon nanotubes41–50 and, as new materials have been developed, reduced graphene oxide51,52 and graphene53–55 in various composites. In the latter case, Kim et al.55 utilised graphene in a sol–gel with titania–Nafion™, producing a composite film modified glassy carbon electrode. The electroanalytical performances allowed the sensing of capsaicin from 0.03 to 10.0 μM with a remarkably low detection limit of 8.6 nM. The authors attributed the low detection time to the target capsaicin molecules directly adsorbing onto the composite-modified GCE surface via π–π interactions between capsaicin and graphene. The composite electrode was used to determine capsaicin in red chile pepper flakes and Chungyang chile peppers.
The electroanalytical determination of capsaicin using a BDD electrode in the presence of sodium dodecylsulfate (SDS) has also been explored. The electrochemical signals were not as strong as observed by others, which can obviously be understood due to the electrode characteristics, but useful analytical output was observed with a possible linear range from 0.16–20 μM with a LOD found to correspond to 0.034 μM.56 This approach was demonstrated to determine the concentration of capsaicin in Turkish hot (red) pepper paste and red pepper flakes.56 Randviir et al.41 reported the use of screen-printed carbon single-walled and multi-walled nanotubes for the electroanalytical detection of capsaicin in both synthetic capsaicin solutions and capsaicin extracted from chiles and chilli sauces utilising both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The authors found that the choice of technique is largely concentration dependent: for the case of low capsaicin concentrations, SW-SPEs are the better choice with CV; and for high capsaicin concentrations MW-SPEs are the better choice for EIS. This has been explained through the use of linear calibration data, which exhibits high levels of linearity for peak height in the case of CV and charge transfer resistance in the case of EIS, with respect to concentration. The analytical performance of CV and EIS was applied to the sensing of capsaicin in chiles and chilli sauces and directly compared to HPLC-UV analysis. Following the theme of using carbon materials with high surface areas, another approach utilised by Xue et al.57 was to utilise the high surface area of mesoporous cellular foams and they demonstrated that capsaicin could be determined in chile peppers, which was found to be in agreement with independent HPLC-UV. In a different approach, Ziyatdinova and co-workers48 have reported the use of a poly(gallic acid)–MWCNT modified glassy carbon electrode. The authors explored the electroanalytical detection of capsaicin, dihydrocapsaicin and nonivamide with detection limits of 2.9, 5.9 and 6.1 nM, respectively shown to be possible (measured separately). In comparison to a bare glassy carbon electrode, the poly(gallic acid)–MWCNT modified glassy carbon electrode exhibited improvements in electron transfer and analytical peak height. The selectivity of the capsaicinoids’ quantification in the presence of ascorbic acid, α-tocopherol and carotenoids is shown to be possible and the authors validated their electrochemical approach in red hot chile peppers successfully against HPLC.48 Another notable approach was reported by Supchocksoonthorn et al.57 who fabricated carbon dots synthesized from iota-carrageenan, which is an abundant food ingredient obtained from seaweed, using a one-step hydrothermal method, shown in Fig. 3A. The carbon dots, with an average diameter of 3.6 nm, were grafted onto an indium tin oxide (ITO) substrate via a one-step thermal annealing process. This carbon dot-grafted ITO electrode was sensitive to capsaicin from 0.05 to 500 μM, with a low detection limit of 5.4 nM. Selectivity was demonstrated towards capsaicin in the presence of multiple interferences: D-(+)-glucose, citric acid, L-ascorbic acid, Na+, K+, Mg2+, Ca2+, Fe2+ and Cl−. The authors validated their carbon dot-grafted ITO electrode towards capsaicin in Cayenne chile pepper, Tabasco sauce and a Thai chile, comparing directly with UV and HPLC-UV which yielded comparable results, providing independent verification that the electrochemical sensor can be used in practical applications, giving rise to accurate and meaningful pungency values.57 The authors reported that the electroanalytical platform could realise results within 5 minutes (excluding sample pre-treatment/extraction). Usefully, they also deduced the diffusion coefficient of capsaicin to be 1.56 × 10−5 cm2 s−1via the Wilke–Chang equation.58
Fig. 3 (A) Schematic representation of the synthesis of carbon dots from iota-carrageenan, the grafting of carbon dots on ITO and capsaicin detection.57 Reproduced with permission from ref. 57. Copyright Elsevier 2021. (B) Electrochemical sensing platform using a platinum electrode modified with MWCNTs with phenylalanine ammonia-lyase enzyme immobilised using Nafion™ for the detection of capsaicin.45 Reproduced with permission from ref. 45. Copyright Elsevier 2016. (C) Overview of the fabrication of a Ag/Ag2O–PSS–rGO composite and the measurement process of capsaicin.51 Reproduced with permission from ref. 51. Copyright Elsevier 2016. (D) Square-wave voltammetry of Bhut Jolokia (A) and Fatalli (B) microparticles immobilised on the surface of the PIGE and immersed in 0.1 M KNO3, pH 11. ΔI is the net response, If is the forward component and Ib is the backward component.59 Reproduced with permission from ref. 59. Copyright Elsevier 2016. (E) Direct differential pulse voltammetry: (A) using a polished glassy carbon electrode and ex situ extractive stripping differential pulse voltammetry, (B) using a phospholipid modified glassy carbon electrode, background subtracted. Sample: bird's eye chili pepper extract.60 Reproduced with permission from ref. 60. Copyright Elsevier 2020. |
The original mechanism for the electrochemical oxidation/reduction of capsaicin was proposed by Kawada and co-workers,33 and later refined in detail by Kachoosangi et al.40 with only minor suggestions provided by Novak Jovanović and co-workers.59 These suggestions accounted for the different solution pHs used by experimentalists where the oxidation of the hydroxyl group in the capsaicin molecule occurs via different pathways,59 but essentially undergoes the same overall mechanism (EE mechanism). Jerga et al.60 explored the electrochemical oxidation of both capsaicin and dihydrocapsaicin using online electrochemical mass spectrometry with a coulometric cell connected to the MS equipped with an electrospray ionization (ESI) source. The authors reported the following reaction mechanism, as shown in Scheme 2. In this scheme, the electrochemical reaction initiates with the single electron and proton transfer from the phenolic hydroxyl group to form the phenoxyl radical 2, which is stabilized by resonance. The conjugated radical 3 is further oxidized to cation 5 and hydrolysed to provide o-benzoquinone 6 and methanol. The reversible redox equilibrium between quinone 6 and catechol 7 is observed voltammetrically.60 Interestingly, another pathway was potentially observed, where the oxidation and subsequent hydrolysis of another resonance form 4 leads to methoxycatechol 9, which is further easily oxidized to the observed methoxybenzoquinone 10.60 We note that the logarithmic mass spectrometry signal intensity vs. applied potential indicates that at high overpotential, the main products are at 290 m/z and 292 m/z (rather than 320 m/z) indicating that the main electrochemical reaction follows: 1, 2, 3, 5, 6, 7 (see Scheme 2). It is reassuring to see that online electrochemical mass spectrometry confirms earlier insights by Kachoosangi et al.40
Scheme 2 Mechanism of the electrochemical reactions of capsaicin and dihydrocapsaicin in acidic aqueous–methanolic media. Values of m/z are indicated for protonated molecules of capsaicin and its reaction products detected in the ESI+ mode of the EC/MS experiment. Solution composition: 50 μM for both capsaicin and dihydrocapsaicin in 0.6625 M HCOOH with 10% (v/v) of CH3OH.60 Reproduced with permission from ref. 60. Copyright Elsevier 2020. |
Note that sample analysis is an important factor not to be overlooked. If you've ever eaten a chile pepper, you might have noticed that the second bite is hotter than the first. This is because the capsaicinoids are, as expected, not evenly distributed in the chile pepper. Some believe the seeds are the spiciest part, but it's actually the flesh near them that sets your tongue on fire. The part of the pepper closest to the stem is reported to be usually the hotter part because it has the highest concentration of capsaicin. This is anecdotal. True evidence, via analytical means, has reported that the highest capsaicin concentrations are found in the ovary (placenta) and in the lower flesh (apex) and the lowest capsaicin content can be found in seeds.61 In summary, clearly the whole chile needs to be sampled, indicating that the limiting step for in-the-field testing of chile peppers will be the sample preparation rather than the analytical methodology itself. Generally, it appears that researchers just adopt an extraction process ranging from simple extraction with solvents such as ethanol, using sonication62 or manual shaking54 or reflux.63 Essentially the process is along those lines, with very little exploration of how this critical step will influence the final electroanalytical deduced SHU value. Interestingly, Lau and co-workers64 have utilised ionic liquids, which are broadly defined as liquids that comprise exclusively ions, have melting points of 100 degrees Celsius or lower and have been widely utilised as non-volatile, tuneable solvents that can be used as extractants.65 To that end, Lau et al.64 explored the ability of ionic liquids to extract capsaicin from bird's eye chile peppers, reporting that the ionic liquids demonstrated superior extraction ability over that of the widely utilised ethanol extraction.64
Other approaches have explored the avenue of electrochemical biosensors for the determination of capsaicin, based on a signal amplification strategy using enzyme technology. As shown in Fig. 3B (ref. 45), a biosensor was constructed based on a platinum macroelectrode modified with multi-walled carbon nanotubes upon which Nafion™ and phenylalanine ammonia-lyase enzyme were added. The authors explored the role of the phenylalanine ammonia-lyase enzyme, observing that an 8-fold increase was possible using the enzyme, suggesting that this was the basis of the observed signal amplification strategy. The biosensor exhibited analytically useful parameters towards the sensing of capsaicin, comparable to other reported electrochemical based sensors (see Table 1). The effect of a range of interferents upon the determination of capsaicin was explored which confirmed the biosensor exhibited selectivity towards capsaicin determination. The authors explored the use of the biosensor for determining capsaicin in real chiles and found the amount of capsaicin to correlate with that recorded by HPLC, with density functional theory calculations suggesting that the interaction of the enzyme with the phenolic component of capsaicin is key to the improvement in terms of the biosensor’s observed sensitivity.45
From an inspection of Table 1, other approaches to developing electrochemical sensors have utilised a range of nanomaterials, for example Wang and co-workers51 reported a Ag/Ag2O-loaded poly(sodium 4-styrenesulfonate) (PSS) functionalized reduced graphene oxide (rGO) composite (Ag/Ag2O-PSS-rGO) for the determination of capsaicin. Fig. 3C presents an overview of the fabrication approach, where GO is exfoliated by ultrasonication with hydrazine and PSS and thermally treated at 90 degrees for 3 h, then washed, centrifuged and freeze-dried. Nanoparticle sized Ag/Ag2O (4 nm diameter) were fabricated via a chemical reduction method and introduced through electrostatic interaction. This composite was electrically wired through the surface modification of SPEs where, using DPV, clear and well defined voltammetric signatures were observed (see Fig. 2). At pH 1.0, the nanocomposite electrode exhibited a linear range of 1–60 μM with a LOD of 0.4 μM towards the sensing of capsaicin.51 The nanocomposite sensor was applied to the determination of capsaicin within red and green peppers and Capsicum frutescens via the standard addition method, which were found to have SHU of 616, 84 and 18422 respectively, corresponding to non-pungency through to moderately pungent.
An interesting approach for capsaicinoid detection is the direct analysis of the microparticles of the sample,59 rather than the routinely applied solution phase detection which also requires sample pre-treatment (prior dissolution/extraction). Novak Jovanović and co-workers59 report the direct determination of the pungency of chile peppers in a solid sample by voltammetric analysis of immobilised microparticles. In this approach, the method simply involves taking an aliquot (∼2 mg) of the solid pepper sample, placing it onto a glazed ceramic tile, forming a spot of finely distributed material, and then abrasively transferring to the surface of a paraffin-impregnated graphite electrode via rubbing the electrode with a circular action.59 This approach was used to determine the pungency of nine hot (Bhut Jolokia, Red Savina, Fatalli, Habanero Orange, Carolina Cayenne, Cayenne, Jalapeño, Ancho and Hungarian wax) chile peppers, demonstrating a simple and rapid electrochemical method for the direct determination of hot peppers’ pungency (see Fig. 3D for the sensor response to Bhut Jolokia and Fatalli chile peppers). Given the insights above that different parts of the chile pepper can give different SHU values, one hopes that the nine samples were indeed finely distributed59 and representative of the whole chile pepper.
In terms of real sample analysis, reports of the effect of interferents upon capsaicinoid detection and comparison to analytical standards (e.g. HPLC-UV) are severely lacking. A particular potential interferent, that is electroactive and a freshness indicator of foods such as chiles, is ascorbic acid.66 Ascorbic acid can easily be determined using carbon based electrodes but very few papers report the sensing of capsaicinoids and ascorbic acid. It has been reported that ascorbic acid is electrochemically inactive in the potential range commonly used for capsaicinoid determination.48 Most reports to date have not undertaken an interferent study45,49,52,62,67–70 and/or have not compared their electrochemical sensor to independent methods (such as HPLC-UV etc.).41,48,50,54,57,60,71–74 The effect of interferents in real samples is less of an issue in chilli foods such as sauces, where capsaicin levels are very high compared to other interfering species. However, for chile peppers the issue becomes more complex due to organic compounds being present;39,41,60,69 it is clear that real sample analyses are directed more to chilli products. If we explore the issue of ascorbic acid further, it has been reported that chile peppers are rich in ascorbic acid.75 The electrochemical oxidation of ascorbic acid is easily achievable at a range of carbon electrodes with the peak potential dependent upon the solution pH.76 Generally the analysis of capsaicin is undertaken at acidic (pH 1.0) levels, where the voltammetric peak potential is also pH dependant.40 At this low pH, the voltammetric waves of capsaicin and ascorbic acid should be resolved from each other, but of course both are dependent upon various factors, such as the electrode material; at insufficient resolution, peak broadening will occur which will hamper electrochemical analysis. We note that Moreno et al.72 have reported the electrochemical detection of capsaicin and ascorbic acid in Cubana Red chile peppers using a glassy carbon electrode, using a simple extraction method, in which the results agree well with independent spectroscopic measurements.72 The authors noted that the electrochemical approach is cheap, simple and fast: 30 min vs. ∼2 h compared to the spectrophotometric method.72 Generally, authors successfully report the determination of capsaicin in real samples validated against HPLC-UV and other approaches mostly in chilli sauce type products; Tabasco sauce appears to be a favourite choice of the electroanalyst. It has also been shown that, in the case of determining capsaicinoids in chile peppers via electrochemical approaches, the results for chiles with low SHU levels do not agree well with independent methods,39,41 with better correlation observed at higher SHU levels where the ratio of capsaicinoids to interferents is in favour of the former. In addition, what is noticeable is that in real samples, both capsaicin and dihydrocapsaicin (with a ratio of 6:4) will be present but generally, the electrochemical sensor is not calibrated to both of them. This is because the oxidation peak potentials of capsaicin and dihydrocapsaicin are nearly identical, reported to be different by only ∼10 mV,60 due to their very similar chemical structures. The total pungency of chile peppers and chilli products is a result of the combination of concentrations of both capsaicin and dihydrocapsaicin (current approaches assume these two chemicals produce the same level of pungency) and the voltammetric response in real samples will be a combination of both of them, thus if standard additions are undertaken, capsaicin is generally chosen to be used.
To overcome any issues of interferents in real chiles and chilli products, an interesting approach is the use of transfer voltammetry,69 where, after the accumulation step, the electrode is removed, rinsed with water and transferred to a new solution containing just the electrolyte. Further electrochemical analysis can then be conducted and ascorbic acid is left behind in the accumulation solution because of its poor adsorption ability on the chosen electrode surface.69 The authors noted that the process resulted in a peak that was about 50% of the height of the original voltammetric peak, but the sensitivity was still better than that when not undertaking the transfer voltammetry and removing the interferent that would have otherwise potentially hampered the electroanalytical determination. Another avenue is via the use of ex situ extractive stripping voltammetry.60 This approach uses a phospholipid modified glassy carbon electrode, which introduces selectivity into the sensing of capsaicinoids but obviously at the cost of sensitivity. In this novel approach, the hydrophobic phospholipid layer stops the transport of hydrophilic anions from the aqueous solution to the electrode surface. The analytical procedure involves the accumulation of capsaicinoids from the sample under investigation for a set period, after which, the electrode is rinsed with deionized water and placed into a new clean cell containing only the supporting electrolyte. To highlight the selectivity of the approach, the phospholipid modified glassy carbon electrode was compared to a bare/unmodified glassy carbon electrode. Fig. 3E shows the voltammetric profiles, using DPV for each electrode, obtained for a real chile pepper sample (bird's eye chile pepper). The voltammetric response using the bare/unmodified glassy carbon electrode shows two peaks, which are attributed to oxidisable, more polar interferents, which the authors suggest could be ascorbic acid and flavonoids. In contrast, the interferent peaks were absent using the phospholipid modified glassy carbon electrode with the ex situ extractive stripping voltammetry approach; the authors report that the latter is more selective to lipophilic capsaicinoids than the former. The authors measured the pungency of 8 chile samples (Foxta, Madras Chilli, Habanero, Carolina Reaper, bird's eye, Bhut Jolokia, Naga Jolokia extract, Habanero extract) using the bare/unmodified glassy carbon electrode (direct DPV), the phospholipid modified glassy carbon electrode (with ex situ extraction DPV) and HPLC-UV. In the electrochemical approaches, both capsaicin and dihydrocapsaicin were measured to allow direct comparison with the HPLC-UV approach. It was observed that both electrochemical approaches under-estimated the pungency of the 8 chile samples in comparison to HPLC-UV. The authors noted that the best correlation was that of the phospholipid modified glassy carbon electrode (with ex situ extraction DPV) with HPLC-UV.60
Fig. 4 (A) First in-the-field prototype for measuring the pungency of chiles and chilli products produced by Oxford University.28 (B) The commercial ChilliPot – the world's first Scoville Meter.30 (C) Photograph of the electrochemical sensor platform (a) on a 25 × 25′′ panel before component assembly and (b) the single sensor platform after assembly. The Roman numerals indicate (i) the screen-printed electrodes, (ii) the chip potentiostat, (iii) the battery management circuitry, (iv) the terminals for the flexible battery (dimensions 29 × 25 × 0.6 mm) situated on the backside, (v) the antenna circuitry for Bluetooth® Low Energy, (vi) microcontroller with an integrated analog-to-digital converter, and (vii) debug circuitry which can be cut off before deployment. (c–e) Photographs of the encapsulation of the electronic components in a 3D-printed mold.78 Reproduced with permission from ref. 78. Copyright Elsevier 2019. (D) Components of the Chilica-Pod portable electrochemical capsaicin sensor: (a) body of the portable electrochemical device, (b) monitor/software, and (c) sensor.54 Reproduced with permission from ref. 54. Copyright American Chemical Society 2020. |
Søpstad et al.78 developed a standalone electrochemical detection platform for capsaicin using unmodified screen-printed carbon graphite electrodes and an electrochemical technique known as coarsely stepped cyclic square wave voltammetry (CCSWV). Fig. 4C shows the standalone sensing platform where the material costs are around 25 euros. Note that the electrodes are non-detachable/disposable, unlike many other electrochemical based sensors. The reason for a preference for disposable electrodes is that a memory effect is observed and the electrode surface retains substances from the last measurement, resulting in falsely higher readings; to circumvent this, SPEs are utilised to alleviate the need for polishing electrode surfaces. Søpstad et al.78 found that to overcome this issue and re-use the electrodes on their sensor, a solution of ethanol and buffer was used to remove any residual peaks from prior measurements. One downside is that the baseline signal becomes amplified which must be a result of surface changes; though not unambiguously defined by Søpstad et al.;78 the authors report that this can be remedied through baseline signal subtraction. Another further consideration not reported on by Søpstad et al.78 is the longevity of the electrodes on the sensor, which are designed to not be removed, requiring the whole platform to be discarded. The authors validated their sensing platform for Tabasco Chipotle, Tabasco Pepper and Tabasco Habanero sauces. These real chilli sauces were diluted in a 1:2 ratio with ethanol and vortexed for >1 min to ensure good extraction efficiency, and centrifuged at 6000 RPM for 5 minutes. The supernatant was extracted and mixed with the buffer in a 1:9 ratio, leaving the final solution with a 1:19 ratio between sauce and buffer;78 clearly this is a sample pre-treatment obstacle to be overcome to realise a true in-the-field sensor. This approach has the benefit that it uses only one direct measurement (no standard addition protocol as utilised in other approaches40,56), simplifying the overall measurement protocol. We note that no independent analytical validation was undertaken to validate the proposed sensor. which clearly is a limitation. This proposed sensing platform has scope to be considered for other electrochemical sensing approaches, helping to bridge the gap between the laboratory and the field, but clearly has issues identified above which need to be overcome for it to be considered further as a potential in-the-field SHU sensor.
Another sensing platform of note is that by Soleh and co-workers54 who utilised N-doped graphene nanoplatelets to modify a disposable electrochemical paper-based analytical device (ePAD) and have fabricated a completely portable electrochemical sensor for capsaicin, termed the Chilica-Pod. Fig. 4D summarises the Chilica-Pod, which comprises a portable electrochemical device, in the shape of a small chile pepper, and contains a small potentiostat, a smartphone interface and a sensor that consists of the ePAD and a sample detection chamber, which has a filter layer (pore size: 0.1 mm) to filter samples prior to measurement. The ePAD fabrication is achieved through the modification of chromatography paper, which is first printed with wax to create a hydrophobic barrier whereupon a three-electrode sensing configuration is screen-printed. Lastly, the SPEs are surface modified with N-doped graphene nanoplatelets and the electrodes are ready to use. While costs are given for each SPE sensor, no cost is given for the overall electrochemical sensing platform. The Chilica-Pod sensor54 was shown to determine capsaicin in procured dried chile samples, which were weighted to a defined mass, to which 2 mL of buffer was added and manually shaken; 40 microliters of the sample was added to the sample detection chamber and the sample was rapidly analysed. The range of SHU values obtained from 6 chile samples ranged from non-pungent up to highly pungent, and the values were independently validated with UV-vis spectrophotometry showing no significant difference between the two analytical approaches, suggesting that the Chilica-Pod sensor has real potential to provide rapid, accurate (not estimated) SHU values in real chile samples.
Footnotes |
† Traditionally, the grain was thought of as the weight of a barleycorn taken from the middle of the ear (0.0648 g). |
‡ As an aside, note that capsaicin does not dissolve in water, but it does in alcohol and fats, thus whole milk and related food groups will relieve a burning mouth and a glass of water will not. To a far lesser extent, so would alcoholic beverages supply such required relief! |
§ Note that the institute is spelt “chile” rather than “chilli”. On their website (https://cpi.nmsu.edu/), which this information is taken from, they inform one that the spelling of the word ‘chile’ has a long and varied history. Chile comes from the term chilli that comes from the Aztec, Nahuatl language. In their FAQs: they state that, according to Jean Andrews, the Spanish spelling was later changed to chile by Spanish-speaking Mexicans and chili in the United States. We note that at the CPI, they prefer the term chile, which refers to the plant or fruit from the plant while the term chili refers to a culinary dish, consisting of meat, beans, tomatoes and chile powder. We shall use this terminology throughout this overview. Further note that the American English spelling is “chili” while the British English is “chilli”. |
¶ The Mad Dog's Revenge Chile Extract (Ashley Food Company) comes with the following warning label on its bottle: I agree, as indicated by my opening this bottle, as follows in connection with my purchase of this product. 1. Due to the extreme hot nature of this product, this product shall be used as a food additive. This product can cause serious injury if directly consumed, ingested or applied to the body. 2. Due to the extreme hot nature of this product, this product shall be used with extreme care in very small amounts. 3. This product is to be used at my risk, and I fully understand the potential danger if used or handled improperly. 4. If I give this product as a gift, I will make the recipient fully aware of the potential danger if used or handled improperly. 5. I hereby disclaim, release and relinquish any and all claims, actions and lawsuits that I or any of my dependent heirs, family members or legal representatives, may have against any party relating to any damage or injury that may result, or is alleged to have resulted, from the use, consumption, ingestion, contact or other use of or from the product. 6. I am not inebriated or otherwise not of a sound mind, and I am fully able to make a sound decision about the purchase of this product. |
This journal is © The Royal Society of Chemistry 2021 |