Issue 10, 2015

Analysis of relative standard deviation of spectral line intensity and intensity ratio in laser-induced breakdown spectroscopy using CuIn1−xGaxSe2 thin film samples

Abstract

The precision of laser induced breakdown spectroscopy (LIBS) measurement is influenced by both the shot noise of the detector and the shot-to-shot fluctuation noise of the laser plasma. Since both types of noise are related to the variation of the photon number, it is hard to clearly estimate the degree of influence by each noise on the measured LIBS signal. In this work, to quantitatively estimate the shot noise of an intensified charge-coupled device detector, a model in which the detector noise is linearly correlated with signal intensity is developed. Using a stable light source for intensity calibration, the correlation parameter of detector noise is determined. By subtracting the relative standard deviation (RSD) of detector shot noise from the RSD of measured LIBS signal intensity or intensity ratio, the variation of RSD due to plasma fluctuation alone was obtained. From LIBS analysis of CuIn1−xGaxSe2 thin films under various experimental conditions (laser energy: 0.16–2.9 mJ, gate delay: 0.12–3.6 μs, spot size: 42 and 104 μm), it was found that the plasma-fluctuation-induced RSD of absolute intensity tended to increase with gate delay and to decrease with laser fluence. The plasma-fluctuation-induced RSD of the intensity ratio, however, tended to initially decrease with gate delay to a minimum value before starting to increase at longer gate delay. The observed behavior of plasma-fluctuation-induced RSD of the intensity ratio is understood to be related to the spectral properties of emission lines and elements of interest.

Graphical abstract: Analysis of relative standard deviation of spectral line intensity and intensity ratio in laser-induced breakdown spectroscopy using CuIn1−xGaxSe2 thin film samples

Article information

Article type
Paper
Submitted
10 Apr 2015
Accepted
31 Jul 2015
First published
31 Jul 2015

J. Anal. At. Spectrom., 2015,30, 2107-2119

Author version available

Analysis of relative standard deviation of spectral line intensity and intensity ratio in laser-induced breakdown spectroscopy using CuIn1−xGaxSe2 thin film samples

J. In, C. Kim and S. Jeong, J. Anal. At. Spectrom., 2015, 30, 2107 DOI: 10.1039/C5JA00139K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements