Issue 2, 2019

Lab-simulated downhole leaching of formaldehyde from proppants by high performance liquid chromatography (HPLC), headspace gas chromatography-vacuum ultraviolet (HS-GC-VUV) spectroscopy, and headspace gas chromatography-mass spectrometry (HS-GC-MS)

Abstract

The ability of different methods to analyze formaldehyde and other leachates from proppants was investigated under lab-simulated downhole conditions. These methods include high performance liquid chromatography (HPLC), headspace gas chromatography-vacuum ultraviolet spectroscopy (HS-GC-VUV), and headspace gas chromatography-mass spectrometry (HS-GC-MS). Two different types of resin-coated proppants, phenol-formaldehyde- and polyurethane-based, were examined. Each proppant was tested at different time intervals (1, 4, 15, 20, or 25 hours) to determine the timeframe for chemical dissolution. Analyses were performed at room temperature and heated (93 °C) to examine how temperature affected the concentration of leachates. Multiple matrices were examined to mimic conditions in subsurface environment including deionized water, a solution surrogate to mimic the ionic concentration of produced water, and recovered produced water. The complexity of these samples was further enhanced to simulate downhole conditions by the addition of shale core. The influence of matrix components on the analysis of formaldehyde was greatly correlated to the quantity of formaldehyde measured. Of the three techniques surveyed, HS-GC-MS was found to be better suited for the analysis of formaldehyde leachates in complex samples. It was found that phenol-formaldehyde resin coated proppants leached higher concentrations of formaldehyde than the polyurethane resin coated proppants.

Graphical abstract: Lab-simulated downhole leaching of formaldehyde from proppants by high performance liquid chromatography (HPLC), headspace gas chromatography-vacuum ultraviolet (HS-GC-VUV) spectroscopy, and headspace gas chromatography-mass spectrometry (HS-GC-MS)

Article information

Article type
Paper
Submitted
30 Jul 2018
Accepted
26 Okt 2018
First published
29 Okt 2018

Environ. Sci.: Processes Impacts, 2019,21, 214-223

Lab-simulated downhole leaching of formaldehyde from proppants by high performance liquid chromatography (HPLC), headspace gas chromatography-vacuum ultraviolet (HS-GC-VUV) spectroscopy, and headspace gas chromatography-mass spectrometry (HS-GC-MS)

J. Schenk, D. D. Carlton, J. Smuts, J. Cochran, L. Shear, T. Hanna, D. Durham, C. Cooper and K. A. Schug, Environ. Sci.: Processes Impacts, 2019, 21, 214 DOI: 10.1039/C8EM00342D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements