Issue 9, 2017

Feasibility of microwave-assisted ultraviolet digestion of polymeric waste electrical and electronic equipment for the determination of bromine and metals (Cd, Cr, Hg, Pb and Sb) by ICP-MS

Abstract

A method for the digestion of polymeric waste electrical and electronic equipment (WEEE) by microwave-assisted ultraviolet wet digestion (MAWD-UV) was proposed for the first time allowing us to obtain a single digest for the further determination of Br, Cd, Cr, Hg, Pb and Sb according to the Restriction of the Use of Certain Hazardous Substances (RoHS) directive. The determination of bromine and metals was carried out by inductively coupled plasma mass spectrometry (ICP-MS). The efficiency of MAWD-UV was compared with that obtained without the UV lamp, using 1 to 7 mol L−1 HNO3 and HNO3 plus HCl (5 + 1) mixtures. A wet acid digestion method combined with ICP-MS, as well as neutron activation analysis (NAA), was used to obtain reference values. Although the UV lamp improved the digestion, thus allowing for the use of diluted solutions, possible losses of bromine were observed using a 3 mol L−1 HNO3 solution. After a careful optimisation, a diluted solution containing 0.5 mol L−1 HNO3 + 0.5 mol L−1 HCl + 5.3 mol L−1 H2O2 provided results that were in agreement with the reference values for bromine and metals in the same digest solution. Spike recoveries ranged from 90 to 113% for all the analytes. The results were compared with the values of certified reference materials (ERM 680k and ERM 681k, low-density polyethylene) digested by MAWD-UV and no statistical difference was observed, except for Cr. Limits of quantification using ICP-MS ranged from 0.010 μg g−1 (Cd) to 4.5 μg g−1 (Br) that were suitable according to the RoHS directive. The MAWD-UV method allowed for the single digestion method using diluted acids and did not require different digestion solutions for bromine and metals, thus providing suitable digestion efficiency without bromine losses.

Graphical abstract: Feasibility of microwave-assisted ultraviolet digestion of polymeric waste electrical and electronic equipment for the determination of bromine and metals (Cd, Cr, Hg, Pb and Sb) by ICP-MS

Supplementary files

Article information

Article type
Paper
Submitted
01 Apr 2017
Accepted
14 Jun 2017
First published
06 Jul 2017

J. Anal. At. Spectrom., 2017,32, 1789-1797

Feasibility of microwave-assisted ultraviolet digestion of polymeric waste electrical and electronic equipment for the determination of bromine and metals (Cd, Cr, Hg, Pb and Sb) by ICP-MS

G. D. Iop, S. R. Krzyzaniak, J. S. Silva, E. M. M. Flores, A. B. Costa and P. A. Mello, J. Anal. At. Spectrom., 2017, 32, 1789 DOI: 10.1039/C7JA00123A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements