Microcystin-leucine-arginine (MC-LR), stands out as the most lethal and broadly occurring variant of microcystins, which are harmful substances generated by cyanobacteria during periods of excessive nutrient enrichment in water bodies. Even at low levels, MC-LR can cause acute or chronic hepatic injury, leading to inflammation and potentially promoting tumorigenesis, thereby imposing a significant burden on human health. Vigilant surveillance of MC-LR is vital for safeguarding both the well-being of the public and environmental security. Optical sensors are particularly advantageous for the detection of MC-LR, owing to their exceptional sensitivity and ease of use. This review presents a comprehensive overview of the current advancements and emerging trends in optical sensors for MC-LR detection, focusing on two primary aspects: recognition elements and optical signal transduction. Recognition elements, including enzymes, antibodies, molecular imprinted polymers (MIPs), and aptamers, are summarized along with their characteristics. The review also thoroughly discusses optical signal transduction and its performance, specifically addressing colorimetry, fluorescence, surface-enhanced Raman scattering (SERS), surface plasmon resonance (SPR), electrochemiluminescence (ECL) and other signal transduction methods. Additionally, the review provides a summary of the achievements and challenges of current optical sensors, as well as future application prospects for MC-LR optical sensors. This systematic review aims to facilitate the further development of optical sensors for detecting microcystins.
Creating sophisticated and sensitive detection techniques for MC-LR is gaining greater significance. A variety of traditional analytical techniques have been recognized for detecting MC-LR, including the enzyme-linked immunosorbent assay (ELISA), protein phosphatase inhibition assay (PPIA), liquid chromatography-mass spectrometry (LC-MS) and high-performance liquid chromatography (HPLC).15,16 ELISA is widely utilized for its specificity and sensitivity in determining MC-LR, despite that the detection procedures involved can be quite time-consuming and cumbersome. PPIA, one of the earliest detection assays for MCs, is straightforward but lacks the ability to distinguish between different MC variants. LC-MS and HPLC are the predominant techniques used for the qualitative and quantitative analyses of various MC variants, however, they require sophisticated instruments and professional operators.
Compared to the conventional analytical methods, sensors demonstrate superiority in sensitivity, selectivity, and portability and have seen rapid advancements for detecting MC-LR.17,18 Sensors are composed of two main parts: the recognition component and the signal transduction component. The recognition component engages with the target analyte, and the transducer converts this engagement into a signal that can be understood and processed.19 Therefore, a systematic and comprehensive summary of the sensors for detecting MC-LR, focusing on recognition components as well as signal transduction, is of great significance. Existing review articles mainly focus on specific detection techniques or particular application scenarios. For instance, some reviews concentrate on DNA nanotechnology-based MC-LR detection, while others emphasize immunoassay methods.16,20 There are also reviews that highlight the development of biosensors, electrochemical sensors or molecularly imprinted polymers (MIPs) for the recognition of MC-LR.21–24 However, these reviews mostly cover only a single technique or application area without comprehensively summarizing advancements in optical signal transduction for detecting MC-LR. And no existing review systematically concludes the recognition elements for MC-LR. This review will cover the entire process from recognition elements to signal transduction, providing a comprehensive perspective on the latest advances in optical sensors for MC-LR detection.
In this overview, we have examined the majority of the studies and advancements in the field of optical sensor technology specifically aimed at detecting MC-LR. It primarily focuses on two key functional units of optical sensors: recognition elements and optical signal transduction (Fig. 1). Recognition elements, which encompass enzymes, biological antibodies, molecularly imprinted polymers (MIPs), and aptamers, along with their performance, are systematically introduced. The developments in optical signal transduction for MC-LR sensors are comprehensively summarized, specifically addressing colorimetry, fluorescence, surface enhanced Raman scattering (SERS), surface plasmon resonance (SPR), electrochemiluminescence (ECL) and other methods along with their underlying mechanisms. The review also highlights the significant applications of these sensors, focusing on linear ranges, detection limits (LOD), and practical applications. Furthermore, the current achievements, challenges and future trends in sensors for MC-LR are concluded. This systematic and comprehensive review aims to provide a crucial foundation for subsequent research on detecting MC-LR and even other cyanotoxins.
![]() | ||
| Fig. 1 The detection of MC-LR utilizing various recognition elements and multiple optical signal transduction methods. | ||
Recently, enzymes responsible for MCs degradation, expressed by bacteria, have been proposed as novel recognition elements for detecting MC-LR. Li and colleagues created a sensor using the enzyme MlrB as a recognition receptor for MC-LR.28 This sensor showed high sensitivity and specificity towards MC-LR, suggesting that these specific degradation enzymes could serve as effective recognition elements for MC-LR detection. However, extensive research is still necessary to fully establish the efficacy and practical application of these enzymes in sensor technologies.
In 1996, Liu and colleagues selected nodularin as the idiotype antibodies (pAb1/r) to produce pAb2/m in mice. Subsequently, the purified pAb2 was then used as an immunogen to generated anti-anti-idiotype antibodies (pAb3/r) in rabbits. The resulting pAb3/r demonstrated high specificity to MC-LR, with an IC50 of 700 ng L−1, but it also cross-reacted with various MC analogues. The IC50 values of pAb3/r for MC-YR, MC-RR, and nodularin were 19.2 μg L−1, 24.4 μg L−1, and 24.3 μg L−1, respectively.29 In 2000, Metcalf et al. developed a polyclonal IgG antibody against MC-LR by immunizing outbred Dutch rabbits. This antibody exhibited cross-reactivity with all microcystin and nodularin variants, including MC-LY, MC-LW, MC-LA and nodularin.30 Subsequently, several other pAbs were produced by immunizing animals with MC-LR hapten.31,32 For example, Xu et al. prepared a pAb with IC50 of 0.054 μg L−1 by immunizing New Zealand white rabbits with MC-LR -KLH.33
In comparison to pAbs, mAbs have garnered greater popularity in the development of MC-LR sensors. In 1995, Nagata et al. successfully produced six novel mAbs, designated as M1A6, M7D4, M8H5, M9D1, M1C2, and M1H4, which specifically recognized the Adda moiety of MC-LR. The affinity constants of these mAbs for MC-LR ranged from 1.5 × 10−7 to 3.1 × 10−10 L mol−1, with M8H5 showing the highest affinity.34 In a subsequent study, Zeck et al. generated a novel mAb (clone AD4G2) against the Adda moiety through the immunization of mice in 2001. The IC50 of AD4G2 for MC-LR was 330 ng L−1.35 To date, numerous mAbs with varying affinities to MC-LR have been produced, including MC4G7 (IC50 = 0.27 μg L−1), C8C10 (IC50 = 1.12 μg L−1), MC8C10 (IC50 = 1.50 μg L−1), and MC10E7 (IC50 = 0.063 μg L−1). These mAbs have been widely employed as recognition components in sensor technology.36–43 Traditional antibodies (pAbs and mAbs) tend to be unstable.
In addition to mAbs and pAbs, antibody fragments have also been incorporated into the construction of MC-LR sensors. Murphy and colleagues generated a specific single-chain fragment variable (scFv) antibody fragment, designated 2G1. This 2G1 scFv exhibited an IC50 to MC-LR of 4.8 μg L−1. However, the 2G1 scFv demonstrated comparable cross-reactivity to MC-YR, MC-LW, MC-LF, MC-LA, MC-RR and nodularin.44 Xu et al. discovered 16 MC-LR-specific phage scFv antibodies from a library derived from a mouse immunized with MC-LR. Among them, the highest efficiency anti-MC-LR phage scFv, designated MscFv7, was efficiently produced in E. coli HB2151, demonstrating an IC50 of 471 ng L−1 against MC-LR. However, MscFv7 demonstrated notable cross-reactivity to MC-RR and MC-YR as well.45 Hassanain et al. digested the MC-LR IgG antibody (110 kDa) to obtain Fab′ fragments (55 kDa) for the sensing of MC-LR. The reduced size of these Fab′ fragments provided advantages in surface coverage on nanoparticles, thereby enhancing the ability of the nanoparticles with specific functionalities to capture the target substance.46 Additionally an A8 scFv was expressed and utilized to recognize MC-LR.47
It is noteworthy that nanobodies and recombinantly engineered antibodies have also emerged as advancements of MC-LR sensors. Researchers led by Pírez-Schirmer selected a highly sensitive nanobody (Nab A2.3) from a heavy-chain-only antibody (VHH) phage display library, with an IC50 value of 370 ng L−1.48 Xu and colleagues designed an innovative recombinant antibody (AVHH–MVH) via splicing anti-MC-LR mouse scFv (MscFv7) and anti-MC-LR alpaca nanobody (ANAb12) through chain shuffling technology, followed by random mutation via site-directed mutagenesis. This AVHH–MVH mutant demonstrated good stability and binding activity towards MC-LR (IC50 = 282 ng L−1).49
Although a large number of antibodies have been quickly developed for the determination of MC-LR, studies have exposed weaknesses in their production: the use of mammalian expression systems makes the process of antibody production time-consuming and laborious. The performance variations among these pAbs, mAbs, antibody fragments, and recombinantly engineered AVHH-MVH in the recognition of MC-LR are summarized in Table 1.
| Type of antibody | Advantages | Disadvantages | Application | Name | IC50 for MC-LR (μg L−1) | IC50 for MC variants (μg L−1) | Ref. |
|---|---|---|---|---|---|---|---|
| pAb | High affinity, low cost | Low specificity | Preliminary screening | pAb3/r | 0.7 | MC-YR (19.2) | 29 |
| MC-RR (24.4) | |||||||
| Nodularin (24.3) | |||||||
| mAb | High specificity and sensitivity | Single epitope, sensitivity to environment | Precision quantitative detection | M8H5 | 0.125 | MC-RR (0.118) | 34 |
| MC-YR (0.295) | |||||||
| MC-LA (0.479) | |||||||
| Nodularin (0.623) | |||||||
| AD4G2 | 0.33 | MC-YR (0.33) | 35 | ||||
| MC-RR (0.46) | |||||||
| MC-LY (0.43) | |||||||
| MC-LW (0.43) | |||||||
| MC-WR (0.35) | |||||||
| MC-LF (0.70) | |||||||
| MC-LA (0.42) | |||||||
| Nodularin-R (0.16) | |||||||
| Adda (0.43) | |||||||
| MC4G7 | 0.27 | MC-YR (0.22) | 35 | ||||
| MC-RR (0.28) | |||||||
| MC-WR (0.29) | |||||||
| MC-HtyR (0.6) | |||||||
| MC-LY (>300) | |||||||
| MC-LW (>300) | |||||||
| MC-LF (>300) | |||||||
| MC-LA (>300) | |||||||
| C8C10 | 0.6 | MC-YR (8.1) | 40 | ||||
| MC-RR (10.9) | |||||||
| MC-LW (>1000) | |||||||
| MC-LF (>1000) | |||||||
| Nodularin (1500) | |||||||
| MC8C10 | 1.50 | MC-YR (11.0) | 39 | ||||
| MC-RR (17.8) | |||||||
| MC-LF (>1000) | |||||||
| MC-LW (>1000) | |||||||
| Nodularin (2000) | |||||||
| MC10E7 | 0.063 | MC-YR (0.050) | 43 | ||||
| MC-RR (0.066) | |||||||
| MC-WR (0.069) | |||||||
| MC-HtyR (0.15) | |||||||
| MC-LY (104) | |||||||
| MC-LF (>1000) | |||||||
| MC-LW (>1000) | |||||||
| MC-LA (>1000) | |||||||
| Nodularin (0.62) | |||||||
| Adda (>1000) | |||||||
| Antibody fragment | Strong matrix penetration, high stability | Reduced affinity, complex expression | In situ analysis | scFv 2G1 | 4.8 | MC-YR (8.06) | 44 |
| MC-RR (7.99) | |||||||
| MC-LF (7.11) | |||||||
| MC-LW (10.08) | |||||||
| MC-LA (6.42) | |||||||
| Nodularin (9.28) | |||||||
| MscFv7 | 0.471 | MC-YR (0.548) | 45 | ||||
| MC-RR (0.506) | |||||||
| MC-LW (4.86) | |||||||
| MC-WR (856) | |||||||
| Nanobodies | Extremely small size, extreme stability | High development difficulty | Direct detection in complex samples | Nab A2.3 | 0.37 | MC-YR (1.01) | 48 |
| MC-RR (0.83) | |||||||
| DM-LR (0.47) | |||||||
| MC-LA (1.2) | |||||||
| MC-LY (6.7) | |||||||
| MC-LW (6.7) | |||||||
| MC-WR (1.12) | |||||||
| DM-RR (0.86) | |||||||
| MC-LF (6.0) | |||||||
| Recombined antibody | Programmable design consistency | High technical threshold, lengthy development cycle | Ultra-sensitive detection, clinical detoxification therapy | AVHH-MVH | 0.282 | MC-YR (0.313) | 49 |
| MC-RR (0.230) | |||||||
| MC-WR (9.72) | |||||||
| MC-LW (5.04) | |||||||
| MC-LF (>2000) | |||||||
| MC-LY (>2000) |
In 2002, Chianella et al. screened five functional monomers for MC-LR employing computational techniques. An MIP, crafted through computational methods, was formulated using midazole-4-acrylic acid ethylester (UAEE) and 2-acrylamido-2-methyl-1-propanesulfonic acid (AMPSA) as the reactive monomers. Compared to methacrylic acid (MAA)-MIP, the computational MIP exhibited an affinity for MC-LR (Kd = 0.3 ± 0.08 nM) that was more than threefold greater than that of MAA-MIP (Kd = 0.9 ± 0.1 nM). Importantly, the MIP showed minimal cross-reactivity with the analogues (MC-YR, MC-RR and nodularin), which is in stark contrast to the behavior of pAbs and even mAbs.51 Zhao et al. employed density functional theory (DFT) calculations to determine the binding affinity of 4 monomers—methacrylic acid (MAA), acrylamide (AM), 2-aminothiophenol (o-ATP) and p-aminothiophenol (p-ATP)—towards L-arginine. They concluded that the combination of p-ATP and MAA was the most appropriate for the molecular imprinting of L-arginine.52 Additionally, two sol–gel MIPs were synthesized. One was prepared using diphenyl-dimethoxysilane (DPDMS), (3-aminopropyl) trimethoxysilane (APTMS), and tetraethoxysilane (TEOS), and the other was made with (3-aminopropyl) triethoxysilane (APTES), TEOS, DPDMS and potassium tetrakis(4-chlorophenyl)borate (TKClPB). Both of these sol–gel MIPs demonstrated high specificity for MC-LR in the company of other species commonly found in environmental water samples.53,54
Recently, the integration of MIPs with inorganic nanomaterials to create MIP-based hybrids has garnered significant research interest. In these hybrids, MIPs serve as the recognition while inorganic nanomaterials are used for separation or signal output. For instance, Pan et al. engineered a graphene oxide-based ternary magnetic molecularly imprinted polymer hybrid (T-MMIP hybrid) for MC-LR. In this hybrid, GO-Fe3O4 served as the base within the in-position copolymerization involving a template molecule (MC-LR), a cross-linking agent (divinylbenzene, DVB) and functional monomer (AM). The resulting T-MMIP hybrid displayed selectivity not only for MC-LR but also for 8 variants (MC-WR, MC-LR, MC-YR, MC-LW, MC-LA, MC-LY, MC-LF and MC-RR).55 Besides, Chen and colleagues employed pyrrole as the functional monomer in the fabrication of MC-LR imprinted polypyrrole (PPy) on a Cu2O/ITO electrode via electropolymerization, which generated specific recognition sites that increased the electrode's selectivity for MC-LR.56 Additionally, various other MIP-based hybrids have been fabricated, including MIP/CNTs,57 MIP/Au NPs,58 MIP@CQDs@SiO2,59 MIP/RGO/Ti–Fe–O NTs.60 In these hybrids, functional monomers such as AMPSA, sodium 4-vinylbenzenesulfonate, (vinylbenzyl)trimethylammonium chloride, vinyl benzoate, APTES, and o-phenylenediamine (o-PD) were used to prepare MIPs on the surface of these nanomaterials. The organic functional monomers employed in the fabrication of MIPs targeting MC-LR are shown in Fig. 2.
![]() | ||
| Fig. 2 The chemical structure of the organic functional monomers utilized while constructing MIPs for specific recognition of MC-LR. | ||
Apart from organic MIPs, the incorporation of MC-LR recognition sites directly into the preparation process of inorganic photocatalytic MIPs has also been documented. Liu and colleagues synthesized a surface molecularly imprinted TiO2@CNTs composite nanostructure (MI-TiO2@CNTs) by directly integrating MC-LR as the template molecule into the precursor solution throughout the synthesis process of TiO2 on CNTs. This method effectively embedded artificial recognition sites for MC-LR within the material. The MI-TiO2@CNT-based sensor that was developed demonstrated exceptional sensitivity and selectivity in the detection of MC-LR.61 MIPs offer distinct advantages in the recognition of MC-LR, such as high selectivity, cost-effectiveness, and stability. However, their complex preparation process, limited regeneration capacity and anti-interference capabilities can restrict their widespread application in certain scenarios.
In 2001, Nakamura and colleagues successfully developed the inaugural aptamer specifically designed to target MC-LR. However, this screened aptamer presented poor sensitivity towards MC-LR with a binding affinity (Kd) of 103 M−1, and showed a higher specificity to MC-YR, limiting its applicability in developing sensors for MC-LR.63 In 2004, Gu and Famulok identified four clone RNAs specific against MC-LR, among which MC25 clone RNA (5′-CCGGGGUAG GGA UGG GAG GUA UGG AGG GGU CCU UGU UUC C-3′) demonstrated relatively high affinity towards MC-LR with a Kd value of 4.6 μM.64 In 2012, Ng and colleagues identified a range of DNA aptamers targeting MC-LA, MC-LR and MC-YR. Among them, AN6 (5′-GGC GCC AAA CAG GAC CAC CAT GAC AAT TAC CCA TAC CAC CTC ATT ATG CCC CAT CTC CGC-3′) exhibited the highest affinity towards MC-LR with a Kd of 50 ± 12 nM.65 Since then, AN6 has been widely adopted in subsequent aptamer-based MC-LR sensors due to its favorable sensitivity and specificity. Aptamers offer several advantages in recognizing MC-LR, including high specificity, high sensitivity, and ease of functionalization. These characteristics make them particularly suitable for developing rapid and sensitive detection methods. However, challenges remain in their complex selection process, susceptibility to nuclease degradation, and non-specific adsorption, which need to be addressed.
Au nanomaterials are one of the most widely used materials in constructing optical sensors. In 2011, Zhu and colleagues reported a G-quadruplex DNAzyme-based immunosensor for detecting MC-LR. Within this research, G-quadruplex-hemin DNAzymes and secondary antibodies were coated on the Au NPs’ surface as new labels (CatG4-AuNP conjugates). These CatG4-AuNPs conjugates could interact with the MC-LR antibodies through the secondary antibodies and could facilitate the H2O2-driven oxidation of ABTS to produce coloured products owing to the peroxidase activity of G-quadruplex-hemin DNAzymes (Fig. 3A). This immunosensor was specifically designed to detect MC-LR over a linear response range (100–10
000 ng L−1), featuring a LOD at 50 ng L−1.69 Apart from serving as a supporting matrix, Au NPs possess the property of color-change due to the aggregation of particles. Li and colleagues engineered a sensor utilizing aptamers for the selective identification toward MC-LR, which was supported by the aggregation of AuNPs. Aptamers were anchored to the AuNPs’ surface via coordination bonds between gold atoms and the nitrogen atoms, which in turn averted aggregation of AuNPs caused by salts. When MC-LR was introduced to the solution containing aptamer-protected Au NPs, the aptamers selectively bound to MC-LR, thereby losing their protective effect against salt-induced aggregation of the Au NPs. This interaction led to a color change of the Au NPs from red to violet–blue (Fig. 3B). This result suggested that the aptamer-based colorimetric sensor was effective for MC-LR detection, with a good linear response (0.5–7500 nM) and a LOD at 0.37 nM.70 Furthermore, an Au NP dimers sensor formed by two DNA-Au NPs and an aptamer was used for colorimetric detection of MC-LR. Within the study, the aptamer underwent a conformational change to bind with MC-LR, leading to the dissociation of AuNP dimers and a shift in the solution's color from blue to red within a 5 minute timeframe (Fig. 3C). This Au NP dimer-based colorimetric sensor demonstrated a linear response range between 0.1 nM and 250 nM and a LOD of 0.05 nM.71
![]() | ||
| Fig. 3 (A) Design and process of G-quadruplex DNAzyme-based immunosensor for detecting MC-LR.69 (B) Schematic illustration of the AuNP and aptamer-based colorimetric sensor and the associated analytical process for detecting MC-LR.70 (C) Schematic illustration depicting the assembly and breakdown of AuNP dimers.71 | ||
Polydiacetylene (PDA) vesicles also exhibit sensitive color changes due to conformational changes in the conjugated backbone of PDA, making them suitable for optical signal transduction. Xia and colleagues incorporated mAbs specific to MC-LR into PDA vesicles, thereby creating MC-LR-recognizing vesicles (PDA-anti-MC-LR). The specific immunological interaction between MC-LR and PDA-anti-MC-LR resulted in a color shift discernible by the unaided eye, attributable to the conformation change of the PDA.72 In addition to direct color change caused by nanoparticle conformational change, indirect color reactions were utilized for signal transduction. For example, Tang and colleagues reported the employment of antibody-modified SiO2-coated magnetic nanoparticles (Fe3O4@SiO2) and aptamer-modified PDA/CuNPs to bind to distinct epitopes on MC-LR, creating sandwich-like complexes that were magnetically extracted. Following the reaction with bis(cyclohexanone)oxaldihydrazone (BCO), the copper in the extracted PDA/CuNPs was oxidized to Cu2+ ions, which led to a detectable absorption at 600 nm. It was discovered that the absorbance intensity demonstrated a linear correlation with MC-LR concentrations between 50 pM and 25 nM, featuring a LOD of 50 pM.73
Recently, the application of hydrogels in sensors has attracted great attention. Abnous et al. described a colorimetric sensor with graphene oxide (GO) incorporated within a hydrogel framework. The aggregation of GO sheets was induced by the interaction of complementary MC-LR aptamers and adenosine strands, with methylene blue (MB) sandwiched between the GO layers. Upon the introduction of MC-LR, the formation of the GO hydrogel structure was impeded due to the absence of complementary strands, causing the solution to turn blue that could be measured spectroscopically (Fig. 4A). This assay showed a LOD as low as 219 pM.74 Additionally, in our previous study, we described a DNA hydrogel encapsulating Cu/Au/Pt trimetallic nanoparticles (Cu/Au/Pt TNs) for colorimetric sensing of MC-LR. Capitalizing on the heightened peroxidase-mimicking activity of the nanozymes, the developed colorimetric biosensor was able to sensitively quantify MC-LR within 4.0 ng L−1–10 μg L−1, with a LOD of 3.0 ng L−1 (Fig. 4B).75
![]() | ||
| Fig. 4 Colorimetric determination of MC-LR. (A) Utilizing GO, a hairpin aptamer, and MB as an optical sensing element.74 (B) Employing DNA hydrogel encapsulating Cu/Au/Pt TNs as a biosensor.75 | ||
Colorimetric signal transduction determination of MC-LR offers several advantages, such as ease of operation, low cost and rapid response, making it suitable for on-site rapid screening and preliminary detection. However, its application in high-precision and complex environments is limited by lower sensitivity, restricted quantitative performance, and susceptibility to interference. Therefore, colorimetric signal transduction usually needs to be combined with signal amplification strategies to enhance detection sensitivity.
QDs are potent materials for emitting fluorescence signals, boasting distinctive optical characteristics such as high quantum efficiency, narrow emission spectrum, photostability and extensive absorption. Feng et al. synthesized a CdSe/ZnS QD-hapten nanoprobe by linking carboxyl-functionalized CdSe/ZnS QDs to aminoethyl-MC-LR. The signal was facilitated by the fluorescence resonance energy transfer (FRET) occurring between the CdSe/ZnS QD-hapten nanoprobes and the Cy5.5-tagged antibodies. This sensor showed a good linear response (0.10–4.0 μg L−1) and a LOD of 0.03 μg L−1.78 Similarly, in the study conducted by Lee et al., they engineered a QDs-aptasensor employing the FRET approach, with magnetized QD525 (MB-QD525) functioning as the donor and the dimeric cyanine PoPo3 dye, which was integrated into the aptamer, serving as the acceptor. After the introduction of MC-LR, the aptamer recognized and bound to MC-LR, releasing PoPo3 molecules from the MB-QD525-aptamer–PoPo3 complex, causing a decreased emission within the linear domain (0.1–100 μg L−1) (Fig. 5A).79 In addition to the FRET-based designs, the inner filter effect (IFE) between Au NPs and MoS2 QDs was applied to design a fluorescence assay for detecting MC-LR by Cao and colleagues.80 Fluorescence emission from MoS2 QDs at 509 nm, upon excitation at 862/800 nm, was diminished owing to the presence of aptamer-modified Au NPs. Once MC-LR was added, the aptamer selectively bound to it. This binding caused the Au NPs to cluster in a saline environment, which in turn inhibited the fluorescence energy transfer. This process effectively restored the upconverted fluorescence of MoS2 QDs (Fig. 5B). Capitalizing on the minimized background interference from the fluorescence upconversion of MoS2 QDs, this aptasensor was used to identify MC-LR in actual water collected from the Gorges Reservoir area in China. It demonstrated a linear correlation from 50 pM to 40.19 nM with a LOD of 10 pM. Furthermore, Xu et al. used silane-doped carbon dots (Si-CDs) as fluorescence materials for ultrasensitive analysis of MC-LR. In their research, pAbs were labeled with horseradish peroxidase (HRP) for binding with MC-LR or coated MC-LR. Following the removal of unbound antibodies, the substrate solution consisting of H2O2 and ABTS was introduced. The HRP catalyzed oxidation of ABTS to its oxidized form (ox-ABTS) caused significant fluorescence quenching of the Si-CDs. (Fig. 5C). Variations in the fluorescence intensity of Si-CDs enable the quantitative detection of MC-LR in the range between 1 ng L−1 and 3.2 μg L−1 and provided a LOD of 0.6 ng L−1.33 Considering that MC-LR may influence the fluorescence of modified QDs, a novel “on–off–on” chemosensing approach was devised for detecting MC-LR using nitrogen and phosphorus co-doped carbon dots (N/P CDs). The fluorescence emission strength of the N/P CDs decreased in the presence of Fe3+ ions, which was attributed to the construction of Fe–O–P bonds between the Fe3+ ions and phosphorus-containing groups on the surface of the N/P CDs. However, upon adding MC-LR, the fluorescence intensity of N/P CDs could be recovered because of the rival coordination of the MC-LR cavity and Fe3+. This strategy demonstrated a linear relationship (50–3000 ng L−1), with a LOD of 17.1 ng L−1.81 Additionally, a fluorescence sensor based on molecularly imprinted polymer-coated carbon quantum dots (MIP@CQDs@SiO2) was fabricated for detecting MC-LR, in which the fluorescence of CQDs was quenched after the adsorption of MC-LR through an electron transfer process.59
![]() | ||
| Fig. 5 (A) FRET based quantum QD525-aptasensor for detecting MC-LR.79 (B) The MC-LR sensing mechanism involving MoS2 QDs for upconversion luminescence and aptamer-conjugated Au NPs.80 (C) The Si-CD-utilized FELISA technique for the quantitative analysis of MC-LR.33 | ||
Carbon materials, for example single-walled carbon nanotubes (SWCNTs) and colloidal graphene (CG), have been exploited as transducers to translate recognition events into discernible fluorescence signals. Liu et al. utilized CG along with MC-LR-DNA conjugates to establish a rival fluorescence-based immunoassay for detecting MC-LR. The MC-LR-DNA probe rapidly adhered to the surface of CG through π–π stacking, which resulted in significant fluorescence quenching due to the excellent quenching performance of CG. On the other hand, the competitive interaction between MC-LR-DNA and anti-MC-LR antibodies disrupted the interaction between graphene and MC-LR-DNA, thereby causing the restoration of the fluorescence signal. The CG-based immunosensor enabled the quantitative detection of MC-LR, achieving a LOD of 140 ng L−1.82 In a separate investigation by Taghdisi et al., SWNTs served as anchors for two distinct aptamers: one specific for MC-LR and another for a fluorescent marker (dapoxyl). Upon MC-LR being introduced, the aptamer designed to bind to the target detached from the SWNTs. This release enabled the aptamer specific to dapoxyl, which was also bound to the SWNTs, to interact with the dye, causing a decrease in fluorescence. The SWNT-based fluorescence sensor demonstrated a broad linear correlation with MC-LR concentrations (0.4–1200 nM) with a LOD of 138 pM.83
Au NPs, owing to their unique optical properties, are also a kind of the most popular nanomaterials in the construction of fluorescent sensors. Au NPs exhibit a surface-enhanced fluorescence (SEF) effect on the fluorophores positioned a few nanometers from the metal surface, while also possessing efficient fluorescence quenching capabilities. Li and colleagues engineered a SEF immunosensor that leveraged gold nano-crosses to amplify the fluorescence signal and employed Cy5 as the fluorescent marker molecule. The fluorescence of Cy5 could be enhanced by the Au nano-crosses without MC-LR being present, since the Cy5-labeled goat anti-rabbit IgG was captured on the Au nano-cross-coated MC-LR-antibodies. Upon MC-LR being introduced, competitive interaction between the free and coated MC-LR for the MC-LR antibodies resulted in a decreased capture of Cy5-labeled goat anti-rabbit IgG on the Au nano-cross-MC-LR antibodies, leading to a decreased fluorescence intensity (Fig. 6A).84 In a related study, Li et al. conjugated the Cy3 dye-labeled complementary ssDNA (Cy3-cDNA) to plasmonic gold nanostars (GNSs) to create Cy3-cDNA-GNS conjugates. The introduction of MC-LR-specific aptamers resulted in the formation of Cy3-cDNA/aptamer duplexes on the GNSs through the process of hybridization. The presence of MC-LR triggered the preferential binding of the MC-LR-specific aptamer to MC-LR, leading to the disassembly of the Cy3-cDNA/aptamer duplexes and causing fluorescence quenching as the Cy3 dye came into close proximity to the GNS surface (Fig. 6B). The fluorescence intensity under steady-state conditions varied directly with the MC-LR concentration spanning between 0.1 and 50 μg L−1, exhibiting a LOD of 0.50 μg L−1. Additionally, a surface-enhanced Raman spectroscopy (SERS) signal was also obtained with a LOD of 770 μg mL−1.85
![]() | ||
| Fig. 6 (A) An SEF immunosensor incorporating Au nano-crosses for the identification of MC-LR.84 (B) Diagram of the dual-function aptasensor utilizing both fluorescence and SERS for MC-LR detection, leveraging plasmonic GNSs.85 (C) Schematic illustration of fluorescence detection of MC-LR relying on AuNP protected-aptamer and DNase I cleavage enzyme activity.86 (D) Aptasensor employing CRISPR-Cas12a technology for the field detection of MC-LR.87 | ||
With the rapid advancements of biology, novel biological signal amplification strategies have been incorporated into the creation of a fluorescence sensor for detecting MC-LR. Xie et al. pioneered a nanofluidic system for the fluorescence identification of MC-LR. In their study, Au NPs adsorbed the FAM-labeled aptamers, quenching the fluorescence of FAM and protecting the aptamers from digestion by deoxyribonuclease I (DNase I) enzyme. The interaction of the aptamer with MC-LR resulted in the formation of an aptamer/MC-LR complex, subsequently releasing from the Au NP surface. Upon the introduction of the DNase I enzyme, it selectively digests the aptamers, which in turn releases MC-LR to serve as an additional target, enhancing the signal and leading to a strong fluorescence emission (Fig. 6C). This amplification approach, which incorporates the DNase I enzyme and AuNPs, demonstrated a broad linear response (0.25 nM–20 nM) and high sensitivity (LOD = 0.83 nM) toward MC-LR.86 Recently, two novel CRISPR-based signal amplification strategies for fluorescence sensing of MC-LR were reported by Yan's and Wu's group, respectively.87,88 In Yan's research, they developed an aptasensor platform, dubbed MC-LR-Casor, that leverages CRISPR-Cas12a for the on-site detection of MC-LR. Initially, the MC-LR-specific aptamer was annealed with a blocker DNA sequence and then attached to magnetic beads (MBs), causing the formation of the MB-aptasensor. Upon binding to MC-LR, the aptamers released the blocker DNA, thereby activating the CRISPR/Cas12a system. This activation led to the rapid cleavage of the fluorescence reporter, resulting in strong fluorescence (Fig. 6D). Leveraging the CRISPR/Cas12a amplification platform, the developed sensing system achieved a LOD of approximately 3 pg L−1.87 In our previous study, we developed an innovative and adaptable fluorescence sensor, termed the Cas14-pMOFs sensor, by fusing the CRISPR/Cas14a mechanism with two-dimensional sheets of porphyrin-based metal–organic frameworks (2D-pMOFs). In this setup, the FAM-labeled single-strand DNA (ssDNA-FAM) was adsorbed onto the Cu-TCPP(Fe) nanosheet to serve as the fluorescence indicator. The complementary DNA to the MC-LR aptamer (cDNA) was designed to act as an activator for the CRISPR/Cas14a system. When the MC-LR is exposed to its corresponding aptamer during incubation, the cDNA was released into the solution, triggering the trans-cleavage activity of Cas14a. This caused the cleavage of ssDNA-FAM into smaller DNA fragments and their subsequent desorption from the Cu-TCPP(Fe) nanosheets, which produced a fluorescence signal. The fluorescence sensor was capable of detecting MC-LR within the span between 0.05 ng mL−1 and 1000 ng mL−1, with aLOD of 0.19 ng mL−1.88
Fluorescence signal transduction offers several advantages in detecting MC-LR, such as high sensitivity, ease of operation and rapid response, making it suitable for on-site rapid screening and preliminary detection. However, the high cost of fluorescent dyes and their susceptibility to quenching by other factors also limit their application in actual samples.
Great strides have been achieved in SERS-based detection systems for tracking MC-LR, primarily concentrating on creation and fabrication of SERS substrates. Noble metals such as Ag and Au are among the most popular materials for SERS substrates, offering enhancement factors up to the order of 1014.90 In 2015, Zhao et al. fabricated SERS-active Au nanoflower-Ag nanoparticles (Au NF-Ag NPs) core–satellite assemblies, using the Y-shaped aptamer hybrid chains to assemble the Au NFs and Ag NPs. The SERS-active assemblies exhibited a substantial enhancement of the local electromagnetic field. With the introduction of MC-LR, the assemblies disassembled, causing a reduction in the SERS signal intensity (Fig. 7A). A direct proportionality was found between the SERS signal intensity of the assemblies and the MC-LR concentrations, spanning between 10 pM to 10 nM, with the LOD reaching 8.6 pM.92 Similarly, Wei et al. modified cDNA and 4-ATP onto Au NPs to prepare a SERS tag and constructed a hairpin aptamer modified magnetic sphere. When MC-LR is present, the hairpin aptamer would open, allowing the SERS tag to connect to the hairpin aptamer through complementary bases (Fig. 7B). As a result, notable Raman signals were produced following magnetic separation, with MC-LR concentrations varying from 100 pg L−1 to 100 μg L−1.93
![]() | ||
| Fig. 7 (A) Schematic depiction of the synthesis process of SERS-responsive Au NF-Ag NP core–satellite configurations aimed at detecting MC-LR.92 (B) Schematic illustration of the operational principle of the hairpin aptamer-based sensor for detecting MC-LR.93 | ||
To further enhance the local electromagnetic field, core–shell nanostructures with ultra-small gaps were fabricated as SERS probes. The Raman reporter could be situated in the interstice between the core and the shell, acting as internal standards, and shielded from external environmental perturbations by the shell. Zhao et al. successfully synthesized SERS-active Au@AgAu nanoparticles with a tunable gap that enhanced the SERS activity. These Au@gap@AgAu nanoparticles were combined with GO/Fe3O4 nanoparticles through π–π stacking interactions between the GO and the MC-LR aptamers. With MC-LR being present, the Au@gap@AgAu nanoparticles detached from the GO/Fe3O4 nanoparticles because of the aptamers’ binding specificity, resulting in a reduced Raman intensity of the SERS tags (Fig. 8A). This SERS-based sensing method demonstrated improved reliability and reproducibility for detecting MC-LR, with a linear detection varying from 10 pM to 100 nM and a LOD of 9.82 pM.94 Luo et al. developed a core–dual shell structured SERS tag consisting of layers of an Au core with a SERS label, a silver shell, and an outer gold shell (Au@label@Ag@Au NPs). The inner Ag shell layer enhanced the plasmonic enhancement and protected the SERS label from environmental interference, while the outer Au shell layer prevented the oxidation of Ag and improved biocompatibility. By attaching aptamers to the outer gold shell, the Au@label@Ag@Au nanoparticles were anchored onto asymmetric gold nanoflowers (AuNFs) that were spread on flat silicon substrates via DNA hybridization, creating core–satellite nanostructures on these substrates. Introducing MC-LR led to the dissociation of Au@label@Ag@Au NPs from the AuNFs, leading to a weaker SERS signal. Notably, this SERS aptasensor is capable of detecting MC-LR and MC-RR, either separately or together, by adopting two different SERS labels, 4-mercaptobenzonitrile (4-MBN) and 4-nitrothiophenol (4-NTP), each with specific aptamers.95 Additionally, Li et al. constructed a SERS tag by coating silica onto the Raman molecule modified plasmonic gold nanostar (GNS) cores (GNS@Raman reporter@SiO2). A SERS immunoassay was designed by immobilizing the mAb onto both GNS@Raman reporters@SiO2 and the quartz chip. The stepwise introduction of MC-LR targets and SERS probes facilitated the formation of a sandwich-like complex, which was subsequently analyzed using SERS technology (Fig. 8B). This SERS sensor displayed a linear dynamic detection range from 10 ng L−1 to 100 μg L−1 and reached a LOD of 14 ng L−1. Importantly, this SERS sensor demonstrated valuable applicability in continuously monitoring dynamic MC-LR production by a Microcystis aeruginosa culture.96
![]() | ||
Fig. 8 (A) Schematic representation of constructing a Raman IS-aptasensor utilizing Au@gap@AgAu NPs-GO/Fe3O4 NP complexes for MC-LR detection.94 (B) SERS-based immunodetection of hepatotoxic MC-LR.96 (C) Schematic depiction of the rapid assembly of HTNP AgClAu : p-GO nanocomposites modulated by aptamers for sensing MC-LR.97 | ||
Graphene-derived plasmonic nanohybrids have likewise been utilized for the fabrication of SERS sensors. To achieve ultrasensitive detection of MC-LR, Ma et al. reported a real-time assembled SERS aptasensor based on hollow triangular nanoplate AgClAu:plasmonic graphene oxide (HTNP AgClAu:p-GO) nanocomposites. In this system, the HTNP AgClAu:p-GO nanocomposites were assembled from networks to a laminar structure through DNA hybridization using a biotin–streptavidin interaction protocol, with Raman reporters simultaneously embedded into the laminar structures. The dynamic assembly procedure could be adjusted in real time with the ratiometric introduction of MC-LR, causing an alteration of the SERS signal (Fig. 8C). This real-time controllable aptasensing approach attained a broad linear response between 0.01 nM and 5 nM and n LOD of 6.3 pM.97
In addition to a single Raman signal output, dual-mode signal transduction has been employed in detecting MC-LR. Tian et al. proposed a dual sensing strategy that combines SERS and FET technologies, utilizing AuNPs/GO composites as the sensing material. This dual-mode biosensor allows for detecting MC-LR qualitatively via its Raman fingerprint spectrum, while quantitatively determining MC-LR through the graphene field effect transistor.98
SERS significantly amplifies Raman signals, thereby greatly enhancing detection sensitivity and even enabling single-molecule detection. This is highly advantageous for detecting low concentrations of MC-LR. Additionally, SERS can simultaneously detect multiple analytes, offering multiplexing capabilities that make it suitable for analyzing complex samples. However, the repeatability of SERS signals is influenced by the properties of the substrate materials. Commonly used metallic substrates like Ag and Au have trade-offs. Ag provides the best enhancement effect but is less stable, whereas Au is more stable but offers weaker enhancement and is more expensive. These factors limit the large-scale application of SERS in the detection of MC-LR.
Herranz et al. modified the SPR chip with a self-assembled monolayer (SAM) and then covalently attached MC-LR to the SAM for detecting MC-LR. This refined SPR biosensor achieved an IC50 value of 0.67 ± 0.09 μg L−1, covered a dynamic range between 0.2 and 2.0 μg L−1, and had a LOD of 73 ± 8 ng L−1 for MC-LR. Capable of conducting four simultaneous measurements within 60 minutes, each SPR chip could be utilized in a minimum of assay and regeneration cycles without substantial decrease in binding affinity. However, this SPR biosensor exhibited high cross-reactivities towards MC-RR (88%) and MC-YR (94%).101 Devlin et al. covalently attached MC-LR to a CM5 chip and used it in a competitive assay with a 4-minute injection period using an in-house produced mAb to detect total MCs. This assay not only had the sensitivity to detect extracellular MC-LR at 0.5 ng mL−1 but also could quantify intracellular microcystin concentrations with a LOD of 50 pg mL−1.102 Tan et al. developed a SPR system that uses frequency-shifted light of different polarizations to stimulate laser heterodyne feedback interferometry (LHFI). This technique amplifies the reflectivity change caused by refractive index (RI) variations on a gold-coated SPR chip surface. The s-polarized light serves as a reference to compensate for noise, thereby enhancing RI resolution. Using antibodies as recognition elements, the system achieves ultralow detection limits for MC-LR (3.9 ng L−1).103 Practical and automated, the SPR/ESP/LRAUV system developed by William et al. integrates an SPR instrument with an environmental sample processor (ESP) and a long-range autonomous underwater vehicle (LRAUV) to detect and quantify particle-associated MCs (pMCs). This system complements existing cyanobacterial harmful algal blooms survey techniques and enhances predictive models for bloom and toxicity forecasts.104
SPR signal transduction offers several advantages, such as real-time monitoring and high sensitivity, making it particularly suitable for studying the interactions between MC-LR and recognition elements, as well as for detecting low concentrations of MC-LR. However, it also has drawbacks, such as expensive instrumentation and a high dependence on functionalization of the chip surface.
Graphene materials co-doped with boron (B) and nitrogen (N) have garnered significant interest for their remarkable luminescence characteristics, particularly in the development of ECL sensors. Wang's team has created a suite of ECL sensors for detecting MC-LR, leveraging B,N co-doped graphene. In their initial setup, the co-doped graphene hydrogels (BN-GHs) were utilized to enhance the steric interference between MC-LR and its corresponding aptamer. With the increasing concentration of MC-LR in the system, the ECL signals progressively diminished. This reduction occurred because the specific binding between MC-LR and its aptamer obstructed the approach of the coreactant TPrA to the Ru(bpy)32+ on the electrode surface, leading to a lowered ECL emission. A direct correlation was observed between the decline in the ECL signal and the increasing concentrations of MC-LR, spanning from 100 fM to 1 nM, with a LOD of 30 fM.107 To enhance the ECL response of B,N co-doped graphene, they designed a luminescent reagent by compositing ZnO QDs and B,N co-doped graphene (BNG/ZnO). By utilizing BNG/ZnO as the ECL luminophore and an aptamer for specific target identification, they developed a cathodic ECL aptasensor for detecting MC-LR. Within this setup, the ZnO quantum dots produce intense ECL emission through their interaction with K2S2O8, and the incorporation of B and N into the graphene matrix substantially boosts the ECL signal strength (Fig. 9A). This synergistic enhancement resulted in a low LOD of 30 fM and a broad detection range from 100 fM to 5 nM.108 Moreover, in order to further improve sensor performance, SPR induction-enhanced ECL technology was introduced. The approach incorporated B and N co-doped graphene quantum dots (BN-GQDs) for luminescence and bismuth nanoparticles (Bi NPs) to generate SPR. Lacking MC-LR, BN-GQDs were linked to Bi NPs through the hybridization of the MC-LR aptamer and its complementary DNA, allowing the ECL emission of BN-GQDs to induce SPR in Bi NPs, which in turn strengthened the ECL response of BN-GQDs, resulting in a high and enhanced ECL signal. However, with MC-LR being introduced, BN-GQDs could not be linked to the Bi NPs, so that the ECL signal decreased (Fig. 9B). Compared to the BN-GHs and BNG/ZnO, this SPR enhanced ECL sensor was beneficial for broadening the detection range (0.01–5000 pM) and enhance the sensitivity (LOD = 0.003 pM).109 In addition to B and N co-doping, the incorporation of P can also enhance the ECL efficiency of CDs and allows for fine-tuning of the ECL wavelength.110
![]() | ||
| Fig. 9 (A) Schematic overview of the development and detection mechanism of the ECL sensing system incorporating BNG/ZnO.108 (B) Schematic portrayal of the fabrication and sensing mechanism of a Bi NP and BN-GQD-based sensor for MC-LR detection via SPR.109 (C) ECL immunodetection system leveraging CdS QDs for MC-LR.111 | ||
Other materials, including Au NPs, CdS QDs, metal–organic frameworks (MOFs) and copper nanoclusters (CuNCs), have been used as ECL transducers.112 In research conducted by Zhang et al., a sandwich-type ECL immunosensor was crafted for detecting MC-LR, incorporating Au NPs and CdS QDs. The Au NPs were deposited on a glassy carbon electrode (GCE) to link with the primary antibody specific to MC-LR (Ab1) and to enhance electron transfer. Meanwhile, CdS QDs were prepared and tagged to the secondary antibody (Ab2), serving as the ECL luminescent labels. With MC-LR being introduced, a sandwich structure was formed, resulting in a strong ECL signal emission via the electron transfer interaction between the CdS QDs that accept electrons and the reduced forms of S2O82− in a phosphate-buffered solution. (Fig. 9C) This ECL immunosensor possessed a linear response to MC-LR ranging from 10 ng L−1 to 50 μg L−1 with a LOD of 2.8 ng L−1.111 MOFs possess high porosity, large specific surface areas and tunable chemical properties, making them one of the most popular materials for ECL.113 Li et al. established an ECL-resonance energy transfer (RET) system for MC-LR monitoring based on 3,4,9,10-perylenetetracarboxylic acid/the metal–organic frameworks NH2-MIL-125(Ti) (PTCA/NH2-MIL-125) and Au NPs. In this system, complementary DNA1 and DNA2 were bound to the surface of PTCA/NH2MIL-125 and AuNPs, separately. The specific MC-LR aptamer served as a linker to connect the DNA1-PTCA/NH2MIL-125 and DNA2-AuNPs. The ECL emission of PTCA/NH2MIL-125 was quenched by Au NPs because of the spectral overlap between PTCA and Au NPs. With MC-LR being included, the aptamer separated from the sensor, breaking the bridge between PTCA/NH2MIL-125 and Au NPs, and the ECL emission was restored. The quantification of MC-LR was accomplished by tracking the elevation in the ECL signal following MC-LR binding, with a sensitivity range spanning from 9.95 pg L−1 to 99.5 μg L−1 and a LOD of 3.58 pg L−1.114
ECL signal transduction is highly effective for detecting MC-LR due to its high sensitivity, low background signal, broad linear range and quick response time, which is ideal for detecting low levels of MC-LR. Nevertheless, issues such as the stability of luminescent reagents, electrode contamination, and the need for rigorous sample pretreatment still need to be addressed.
Based on the aforementioned discussion, various optical strategies including colorimetry, fluorescence, SERS, SPR, ECL signalling and other signal transduction methods have been successfully employed for detecting MC-LR. The performance characteristics of these optical sensors for detecting MC-LR are summarized in Table 2.
| Method of detection | Recognition elements | Nanoparticle/composite used | Linear range (μg L−1) | LOD (μg L−1) | Sample type | Ref. |
|---|---|---|---|---|---|---|
| Colorimetry | Ab | G4-AuNPs conjugates | 0.1–10 | 0.05 | Lake water | 69 |
| Apt | AuNPs | 0.5–75 000 |
0.37 | Tap/pond water | 70 | |
| Apt | Au NPs dimers | 0.1–250 | 0.05 | River water, PBS buffer and human serum | 71 | |
| mAb | PDA vesicles | 1–100 | 1.0 | — | 72 | |
| mAb and Apt | PDA/CuNPs | 0.05–25 | 0.05 | Drinking/river water, orange juice and milk | 73 | |
| Apt | GO hydrogel | 0.65–1000 | 0.217 | Tap water and serum | 74 | |
| Apt | Cu/Au/Pt TNs-encapsulated DNA hydrogel | 0.004–10 | 0.003 | Tap and drinking water | 75 | |
| Fluorescence | mAb | CdSe/ZnS QDs/Cy5.5 dye | 0.10–4.0 | 0.03 | Water | 78 |
| Apt | MB-QD525/PoPo3 dye | 0.0001–100 | 10−4 | Cyanobacterial culture and river water | 79 | |
| Apt | MoS2 QDs and Au NPs | 0.05–40 | 0.01 | Reservoir water | 80 | |
| pAb | Si-CDs/ABTS/H2O2/HRP | 0.001–3.20 | 6 × 10−4 | Tap/lake/drinking water and crucian | 33 | |
| Coordination of Fe3+ | N/P CDs | 0.05–3 | 0.017 | Tap/sea water | 81 | |
| MIP | MIP@CQDs@SiO2 | 1–1000 | 9.3 × 10−3 | Lake/tap water | 59 | |
| mAb | Colloidal graphene | 0–500 | 0.93 | Lake/tap water and PBST buffer | 82 | |
| Apt | SWNTs and dapoxyl | 0.4–1200 | 0.137 | Tap water and serum | 83 | |
| Ab | Au nano-crosses/Cy5 | 0.02–16 | 0.007 | Fish | 84 | |
| Apt | GNSs/Cy3 | 0.1 to 50 | 0.50 | Tap/lake/river water | 85 | |
| Apt | Au NPs/FAM/DNase I enzyme | 0.25–20 | 0.83 | Tap water | 86 | |
| Apt | CRISPR/Cas12a/FAM | 1 × 10−5–10 | 3.02 × 10−6 | River water | 87 | |
| Apt | CRISPR/Cas14a/FAM/2D-pMOFs | 0.05–1000 | 0.019 | Tap/drinking water | 88 | |
| SERS | Apt | Au NF-Ag NP | 0.01–10 | 8.6 × 10−3 | Lake water | 92 |
| Apt | MNPs/AuNPs | 0.01–200 | 0.002 | Tap water | 120 | |
| Apt | Au@gap@AgAu NPs and GO/Fe3O4 NPs | 0.01–100 | 9.82 × 10−3 | Lake water | 94 | |
| Apt | Au@label@Ag@Au NPs | 10–100 | 8 × 10−4 | M. aeruginosa culture | 95 | |
| mAb | GNS@Raman reporter@SiO2 | 0.01–100 | 0.014 | Tap water and M. aeruginosa culture | 96 | |
| Apt | HTNP AgClAu : p-GO |
0.01–5.0 | 6.3 × 10−3 | Reservoir water | 97 | |
| Apt | AuNPs/GO composite | SERS for qualitative detection | Deionized/tap/fresh lake water | 98 | ||
| FET for quantitative detection | ||||||
| SPR | mAb | Self-assembled monolayer | 0.2–2.0 | 0.073 | Drinking water | 101 |
| mAb | CM5 chip | 0.69–4.24 | 0.005 | Cyanobacterial cultures | 102 | |
| mAb | SAMs on the SPR chip | 0.013–1.01 | 0.0039 | Lake water | 103 | |
| ECL | Apt | BN-GHs | 10−4–1.0 | 3.0 × 10−5 | Tap/contaminated water and human serum | 107 |
| Apt | BNG/ZnO | 10−4–5.0 | 3.0 × 10−5 | Tap/lake water | 108 | |
| Apt | BN-GQDs and Bi NPs | 3.0 × 10−5–5.0 | 3.0 × 10−6 | Tap/lake water | 109 | |
| mAb | CdS QDs. | 0.01–50 | 0.0028 | River water | 111 | |
| Apt | PTCA/NH2MIL-125 and AuNPs | 9.95 × 10−6–99.5 | 3.58 × 10−6 | Tap/river water | 114 | |
| LSPR | Ab | Antigen–ovalbumin modified biological magnetosomes | 1–20 | — | Seafood | 117 |
| CL | Nanobody | — | — | 0.33 | Lake water | 118 |
| Ab | HRP-functionalized Si NPs | 0.02–200 | 0.006 | Tap/lake/bottled drinking water | 119 | |
The selection of suitable recognition receptors is a critical determinant of sensor performance. Initially, protein phosphatases were introduced as recognition receptors in sensors for MC-LR, but their poor specificity led to their gradual replacement by other recognition elements. Recently, the microcystin degradation enzyme, MlrB, has emerged as a promising recognition element with potential applicability. However, it requires further investigation. pAbs, mAbs, antibody fragments, and AVHH-MVH exhibit high affinity for MC-LR, with IC50 values as low as 0.06 μg L−1, and are widely employed in MC-LR sensor construction. Nevertheless, these antibodies exhibit considerable cross-reactivity with MC variants, particularly MC-RR and MC-YR. MIPs offer unparalleled advantages over other biomolecules in terms of chemical, mechanical, and storage stability. The selection of appropriate functional monomers and polymerization methods is crucial for fabricating high-affinity MIPs with MC-LR-specific cavities. Aptamers have demonstrated considerable advancement in serving as recognition elements in biosensors, attributed to their specificity and strong binding affinity. A high-affinity aptamer for MC-LR, with a Kd value of 50 nM, has been selected and widely applied in sensors. However, major limitations remain before aptamers can be widely adopted, such as the impact of ionic strength, total protein concentration, and temperature on biosensing performance. Taken together, these recognition elements each exhibit distinct advantages. The selection of an appropriate signal recognition element should be based on the subsequent signal transduction approaches, sample characteristics, and detection fields. Furthermore, improving the specificity and affinity of these enzymes, pAbs, mAbs, MIPs, and aptamers through biological or chemical modifications, and developing new recognition units with superior selectivity and sensitivity toward MC-LR, should be areas of further study.
For optical signal transduction, ingeniously designed strategies have been successfully implemented for detecting MC-LR, with a specific emphasis on the colorimetric, fluorescence, SERS, SPR, and ECL sensing strategies. A range of nanomaterials, such as QDs, noble metal nanomaterials, carbon-based nanomaterials and MOFs, have been employed to transduce the recognition information into an optical signal. These optical sensors have demonstrated potential practical applications, achieving accurate quantification of MC-LR in actual water samples, and in some cases, in complex samples such as serum and tissue. However, several challenges remain. The majority of optical sensors remain in the experimental phase, concentrating on the demonstration of concept and validation. Additionally, linking recognition elements with nanomaterials for functionalization can inevitably add to the complexity, expense, and time needed for the development of optical sensors. Moreover, this conjugation might diminish the recognition elements’ ability to distinguish targets effectively.
With the remarkable progress in the design of optical sensors for MC-LR detection, tremendous opportunities and attractive application prospects are emerging. The following aspects are worth paying attention: (1) although the MC-LR exhibits the highest toxicity among MCs, other harmful cyanotoxins are also present in most of the water resources and also require attention. Therefore, the development of optical sensors with multi-target detection capabilities, combined with high-throughput detection tools such as microfluidics, is recommended for simultaneous detection of MC-LR and other cyanotoxins. (2) Owing to the simplicity of optical sensing, integrating field-deployable devices holds promise for on-site applications. Leveraging compact devices and wireless connectivity, the binding event of MC-LR can be transformed into a quantifiable digital signal using portable devices like smartphones, with the analysis results being sent to remote servers. This method enables field detection, moving beyond the confines of a laboratory setting, and heralds the advent of a new class of analytical tools for real-time surveillance. (3) Benefiting from the appreciable sensitivity of the optical sensors, a suitable prediction system for the early determination of MC-LR at picogram levels during cyanobacteria bloom could be constructed based on the integration of optical sensing with multi-disciplinary technologies, which could significantly enhance environment safety and human health protection.