Open Access Article
Hannah
Varner
a and
Tal
Cohen
*ab
aDepartment of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
bDepartment of Civil and Environmental Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA. E-mail: talco@mit.edu
First published on 6th September 2024
Accuracy in the measurement of mechanical properties is essential for precision engineering and for the interrogation of composition–property relationships. Conventional methods of mechanical testing, such as uniaxial tension, compression, and nanoindentation, provide highly repeatable and reliable results for stiff materials, for which they were originally developed. However, when applied to the characterization of soft and biological materials, the same cannot be said, and the spread of reported properties of similar materials is vast. Polydimethylsiloxane (PDMS), commonly obtained from Dow as SYLGARD 184, is a ubiquitous such material, which has been integral to the rapid development of biocompatible microfluidic devices and flexible electronics in recent decades. However, reported shear moduli of this material range over 2 orders of magnitude for similar chemical compositions. Taking advantage of the increased mechanical scrutiny afforded to SYLGARD 184 in recent years, we combine both published and new experimental data obtained using 9 mechanical test methods. A statistical analysis then elucidates the significant bias induced by the test method itself, and distinguishes this bias from the influence of curing protocols on the mechanical properties. The goal of this work is thus two-fold: (i) it provides a quantitative understanding of the different factors that influence reported properties of this particular material, and (ii) it serves as a cautionary tale. As researchers in the field of mechanics strive to quantify the properties of increasingly complex soft and biological materials, converging on a standardized measurement of PDMS is a necessary first step.
Even commercially available synthetic materials are hard to test. One example is polydimethylsiloxane (PDMS) where reported elastic moduli range by 2 orders of magnitude for similar compositions, as shown herein. PDMS is a two-part material system and the stiffness of the resulting silicone polymer can be easily tuned to suit the needs of an application. PDMS will cure at room temperature, or can have the curing accelerated with an oven cure. It is widely used in microfluidics,4–6 medical devices, and electronics.7–9 In engineering mechanics, it is a common surrogate material for method development in the measurement of elastic, adhesion, and fracture response,10–14 and as a component in the development of tough materials that can undergo large deformations before failure.15–21 The flexibility of composition and cure is particularly useful in the context of biological research where PDMS has been proposed as a scaffold for cell growth,22–25 as a biological membrane mimic in microfluidics,26 and in biohybrid devices.27–29 Given its widespread use in biology, numerous authors have worked to modify the adhesion, wetablity, absorptivity, dielectric properties, and mechanical characteristics of PDMS, with comprehensive reviews provided by Wolf et al.,30 Zhou et al.,31 Abbasi et al.,32 Teixeira et al.33 and Murphy et al.34 However, far less attention has been paid to systematically understanding and measuring the bulk properties of PDMS (or, often, the commercially branded product Dow SYLGARD 18435). The same fabrication flexibility and wide availability that makes commercial SYLGARD 184 applicable across a range of fields also highlights a critical problem of mechanical reproducibility.
The primary goal of this work is to elucidate the bias induced by the testing method in determining the elastic response of soft materials. To this end, we choose SYLGARD 184 as a test case, taking advantage of the breadth of available data in the literature spanning a range of test methods, and combined with new volume controlled cavity expansion (VCCE) data, reported here. The secondary goal of this work is, thus, the interrogation of SYLGARD 184 mechanical properties. While frequent users of SYLGARD 184 often expect minor inconsistencies in the mechanical properties due to changes from the manufacturer‡, we hypothesize instate that measurement discrepancies can be mainly attributed to bias imparted by: (1) different mechanical testing methods, and (2) wide variation in the cure conditions used for similar mixing ratios.
“Round Robin” studies have been used to compare test methodologies and increase the “reliability and repeatability” of measurements in ceramics,39,40 composites,41 adhesives,42 concrete,43 steel,44 and many other materials and industries. In their versailles advanced materials and standards report, Kubler et al.39 articulate their motivation for conducting the study to determine if the Single-edge-V-Notched beam method for measuring fracture toughness is “user-friendly, reliable and… comparable to other recognised methods.” A similar effort in the context of PDMS elasticity characterization is, in the view of the authors, overdue. To this end, we embark on this study in an effort to understand the magnitude of the problem at hand. We present the scale of variability observed across literature and in our own data, and hope to motivate the community to converge on more consistent preparation, and testing methodologies to improve repeatability for PDMS and across the field of soft material mechanics.
This paper is organized as follows: we begin by describing how studies were chosen for inclusion in this meta-analysis (Section 2.1) and provide a brief description of the mechanical testing methods used across the included studies (Section 2.2). We then present the results of our analysis (Section 3) and include new data for moduli obtained via VCCE (detailed in Section 2 of the ESI,† Table T1). Finally, we conclude with remarks and cautions on stiffnesses reported in literature for PDMS (Section 4).
All included studies are summarized in Table T2 of Section S3 (ESI†). Studies with parameters listed as “variable” intentionally survey a large range of values and are therefore not listed in the table (though included where appropriate in corresponding figures). New data collected by the authors and included in Table T2 (ESI†), is described in Section S2 (ESI†) with fabrication and measurement detailed in T1 (ESI†).
Dow recommends a mixing ratio of 10 parts base to 1 part curing agent (crosslinker) on a weight to weight basis; we will abbreviate this as 10
:
1 or more generally wB
:
wC. Where the mix ratio was instead reported as a percent, we have converted to the X parts base:1 part curing agent format. All stiffnesses are reported here as shear modulus, μ. Where authors initially reported the stiffness as an elastic or Young's modulus, E, incompressibility is assumed with a Poisson's ratio ν = 0.547 and μ = E/(2(1 + ν)) = 3E. For studies investigating viscoelastic material parameters or high strain rate responses, the quasistatic modulus is reported in the summary charts and where only an instantaneous modulus is reported, we denote it as μ0. For studies reporting a cure at room temperature, 25 °C was used in plotting and comparison tables.
![]() | ||
| Fig. 1 Common types of testing used to determine shear or elastic modulus, μ and E for PDMS. Variable definitions are included in the text. | ||
:
1 base to curing agent ratio.
![]() | (1) |
Li et al.66 use similar assumptions in a cylindrical geometry, finding a very good match between analytical and experimental results.
.
with I describing the second moment of area. By contrast, Du et al.72 considered a point load at the tip of a low aspect ratio beam and added a Timoshenko term
with the shear coefficient α.
The correlation is executed via MATLAB 2023 and is applied between preparation conditions (cure temperature, time) and within subgroups of individual test methods in order to isolate where monotonicity might hold internal to a test method, but not within the entire population. While ρ provides indication of how monotonic the relation between two inputs is (0.3 ≤ |ρ| < 0.6: fair, 0.6 ≤ |ρ| < 0.8: moderate, 0.8 ≤ |ρ| < 1: very strong, |ρ| = 1: perfect76), it does not indicate the magnitude or linearity of an effect.
:
1 ratio
Table 1 presents the Spearman correlation between shear modulus and key process parameters: curing agent ratio, cure temperature, and cure time. Correlations are calculated for all tests and cure ratios combined using the number of data points Ntests listed in Table 1, then separately for select testing methods with data from multiple authors (and conditions) for Ntests > 10. The second section of the table presents only tests performed at the 10
:
1 ratio (that recommended on the product technical data sheet (TDS)35), followed by those excluding this ratio.
:
1 wB
:
wC in order to remove the disproportionate number of tests recorded at this ratio from biasing the results. Blanks in the table indicate cases where conditions are the same for all trials within the row
| Test type | N datasets | N tests | Curing agent ratio | Cure temperature | Cure time | |||
|---|---|---|---|---|---|---|---|---|
| ρ | p | ρ | p | ρ | p | |||
| All tests | 36 | 178 | −0.88 | 0.00 | 0.32 | 0.00 | −0.29 | 0.00 |
| Cavitation rheology | 3 | 16 | −0.98 | 0.00 | ||||
| Compression | 2 | 11 | −0.94 | 0.00 | 0.52 | 0.10 | −0.52 | 0.10 |
| Nanoindentation | 9 | 30 | −0.90 | 0.00 | 0.72 | 0.00 | −0.37 | 0.05 |
| Tension | 12 | 66 | −0.44 | 0.00 | 0.43 | 0.00 | −0.16 | 0.20 |
| VCCE | 4 | 25 | −0.92 | 0.00 | −0.85 | 0.00 | 0.85 | 0.00 |
All tests 10 : 1 |
27 | 53 | 0.30 | 0.03 | −0.37 | 0.01 | ||
| Tension | 12 | 38 | 0.26 | 0.12 | −0.46 | 0.00 | ||
All tests excluding 10 : 1 |
24 | 122 | −0.92 | 0.00 | 0.24 | 0.01 | −0.13 | 0.14 |
| Nanoindentation | 6 | 23 | −0.91 | 0.00 | 0.61 | 0.00 | −0.05 | 0.82 |
| Tension | 6 | 28 | −0.63 | 0.00 | 0.62 | 0.00 | 0.33 | 0.09 |
Tension testing results tend to be less correlated than other test methods. All comparisons between stiffness and curing agent ratio indicate very strong correlations with an exceptionally low p-value, as expected from the reaction chemistry described in ESI.5.† However, for those tests performed using tension testing, the correlation is only fair to moderate. Examining cure temperature, when all curing agent ratios are considered, the correlation with cure temperature is higher within tension testing than across other methods. However, at the 10
:
1 ratio where one would expect the dependency to be most cleanly expressed given the elimination of one variable entirely, this trend does not hold and the data fail the correlation with p = 0.12. Cure time is weakly correlated when examining all tests combined. However, within individual test methods correlation routinely fails the null hypothesis and predicts a weaker or inverted correlation when evaluated with tension testing. Across all test methods and within tension testing, additional data are required to conclude that there is monotonic correlation.
Note that in the TDS, Dow reports a tensile modulus of 6.7 MPa for a 10
:
1 mix ratio.35 Though not included in Fig. 2 or Table 1 given incomplete information on test method and cure conditions, this is significantly above all results compiled here.
We hypothesize that the variation imparted by test method is driven by a number of factors including, but not limited to: material rate dependence, such that different methods measure the instantaneous vs. relaxed modulus, the additional models required to separate stiffness from adhesion effects in contact measurements, and sample preparation and fixturing imparting imperfections in boundary conditions and defect nucleation.
In an effort to isolate the influence of cure schedule from that of the test method, Fig. 3 compares stiffness for samples cured 120 minutes at 85–100 °C across multiple authors. Particularly for the lower wB
:
wC ratio samples, the measured stiffness varies by hundreds of kilopascals between testing methods. Tension testing inconsistently reports moduli both higher and lower than nanoindentation, and is not used for softer samples. While the general softening trend with higher base ratios can provide a rough qualitative understanding of polymer composition's influence on stiffness, there is minimal overlap in test methods that are used between soft samples and stiff samples, leaving open the question that the trends are due to the test methodology.
![]() | ||
| Fig. 3 Test method imparts variability even when a similar cure schedule is used: 120 minutes at between 85 and 100 °C. Test type indicated by marker shape matching those used in Fig. 2. | ||
Restricting the wB
:
wC ratio to a more narrow range and examining three cavity-expansion based methods, encourages caution about biases that may be more pervasive in the dataset. Fig. 4 compares the μ0 of Yang et al.69 measured through CR and assuming a neo-Hookean material model, to results obtained via VCCE for comparable mix ratios (oil containing samples are excluded). The VCCE results from Raayai-Ardakani et al.11,64 are also μ0, while those of Chockalingam et al.65 and this work are μ.
![]() | ||
Fig. 4 VCCE results of11,64 for μ0 (filled marker), as well as μ from Chockalingam65 and this work (unfilled cyan circle, cyan axis labels) compared to CR results for μ0 by Yang et al.69 Horizontal green lines specify the measured μ0 from cavitation rheology for comparable mix ratios (wB : wC as noted on plot) measured with VCCE. Dashed lines are visual aids depicting both a 1 : 1 correlation for μ : μ0 and lack of correlation for μ0 : μ0. | ||
As expected from a solid mechanics perspective, μ < μ0 when measured with VCCE with instantaneous moduli more than double the quasistatic moduli for comparable wB
:
wC ratio. However, in these datasets, all samples used to measure μ were cured hotter and for less time than all samples to measure μ0. This results in the inversion of ρ in Table 1 for both cure temperature and time when considering VCCE independently. This inversion is another indication that the comparison of measured stiffness between different test methods and/or cure protocols can be misleading.
Furthermore, it can be seen on Fig. 4 that μ0 does not correlate 1
:
1 between CR and VCCE. The observed deviation between Raayai-Ardakani and Yang et al. can therefore be attributed to the 6 day room temperature cure of Yang et al. producing softer samples than the 3 days at 40 °C cure schedule used by Raayai-Ardakani. By contrast, the unexpected 1
:
1 correlation between μ0 by CR and μ by VCCE (blue line on Fig. 4) is likely attributed to the discrepancy between the room temperature cure schedule used by Yang et al.69 and the 100 °C 2 h schedule used by Chocaklingam et al.65 and this work.
:
curing agent ratios, with larger ratios being more often cured at room temperature and never over 150 °C compared to the stiffer, low ratio, samples. This likely compounds the effect of higher mix ratio samples appearing softer due to both lower temperature and less curing agent.
Table 1 also shows the counterintuitive result that longer cure times correlate with softer samples, however this is likely due to the significantly longer times used with room temperature curing. While stiffness does not follow a linear trend with all predictor variables (as is clear from Fig. 3) a basic regression performed on the complete data set provides insights into the relative importance of temperature, time, and curing agent ratio. Utilizing MATLAB 2023b to fit a linear regression model, cure temperature is connected to stiffness as 2.71 kPa °C−1 (standard error SE of 0.74 kPa °C−1) while cure time is effected as 0.004 kPa min−1 cure (SE 0.006 kPa min−1 and a p > 0.05, thus failing the assumption of a linear correlation). Curing agent ratio is most strongly linked to stiffness as −15.5 kPa/1 wB+oil (SE 1.7 kPa/1 wB+oil). Contour plots depicting the interplay between all three predictors can be seen in Section S6 of the ESI.† With the strength of the correlation between temperature and stiffness, the tendency of lower temperature curing to produce softer samples overshadows the effect of longer cure times producing stiffer samples.
In an effort to reduce the variability imparted by different test methods, Table 1 is subdivided by test types and further to isolate 10
:
1 ratio samples. Across nanoindentation and tension testing, the correlation between cure temperature and stiffness increases to moderate – strong when test methods are considered independently, and is even stronger when 10
:
1 ratio samples are excluded (confirming that the number of tests performed only at this ratio may be biasing the overall trends in results).
There is, however, a limit at which higher temperatures will no longer produce stiffer samples and instead will degrade the polymer. Liu et al.51 set out to study the effect of heating on PDMS mechanical properties and also observe that stiffness increase between 100 and 150 °C, but decreases for 200 °C and 300 °C samples.¶
Fig. 6 shows that the correlation of shear modulus to mix compositions is stronger when the added oil is included in the wB than when it is not. The correlation for Yang et al. increased to |ρ| = 0.96 from |ρ| = 0.47 and |ρ| = 0.85 from |ρ| = 0.74 combining Chockalingam et al. and this work. Across both sets of data, increasing wB+oil
:
wC reduces the observed shear modulus (μ or μ0) by a similar amount (0.768 vs. 0.766 kPa per added wB+oil with a linear fit to the data in this region). While all authors report changes to the viscoelastic time constants when including nonreactive oils, the trend in softening with increasing wB+oil for soft PDMS is shown to be consistent (a) regardless as to whether the ratio is altered with base or oil, and (b) in both instantaneous and quasistatic modulus.
![]() | ||
Fig. 6 If wB : wC is considered without taking oil into account (crosses), the correlation of ratio with stiffness is not as strong as when wB+oil : wC is considered (circles) and the R2 of a linear fit drops from 0.88 to 0.21 for CR and 0.83 to 0.31 for VCCE. (a) shows μ0 from Yang et al.69 against an abscissa calculated both with and without oil included in wB; (b) depicts μ from Chockalingam et al.65 and this work. | ||
Recent work by Bardelli et al.78 points to cure temperature as a factor in changing the molecular weight between crosslinks Mc in PDMS. As described in ESI.5,†Mc is directly connected to the stiffness of a polymer. Bardelli et al. observe nearly a doubling of μ between a 4 hour cure at 65 °C compared to 150 °C (with Mc decreasing from 2050 to 1050 g mol−1). Additionally, if lower temperature cures allow for more secondary reactions to take place, this could explain the resulting solid being softer.
Test method has been implicated previously as returning variable measurements within identical soft material samples, and PDMS is no exception. Tension tests on PDMS reported the widest variation of stiffness, with nanoindentation also providing widely variable results. Though these are both common testing techniques, we recommend caution in the use of both methods. At low mixing ratios PDMS is brittle54 and tension testing is highly sensitive to surface imperfections on the sample, while at higher wB
:
wC ratios, the soft modulus means that results are influenced by the clamping conditions, without a guarantee that it is possible to set up a successful test at all. The variability of nanoindentation is likely due to the uncertain nature of the adhesion between the sample and indenter tip, which was the focus of many of the authors referenced here. Using such a method that relies on consistent surface adhesion, in a material where surface treatments are applied to widely varying degrees, will continue to produce imprecise results.
The limitations of testing make it challenging to characterize the composition–property relationship of SYLGARD 184. This difficulty is further accentuated by the inconsistency of fabrication conditions and reporting of curing protocols. At present, cure schedules ranged widely between researchers with very little overlap if the authors were not currently or historically from the same research group. Of utmost importance is fully reporting the cure schedule and preparation method, as well as timing between cure and test. Unifying how PDMS is cured to obtain well characterized responses could help to enhance data comparisons and reliability. Hence, we would propose three temperatures for PDMS where control of mechanical properties is desired: a 25 °C room temperature, a “moderate” 60 °C at or below the glass transition temperature of plastics commonly used in additive manufacturing, and a “hot” 100 °C for rapid curing. Curing times may vary depending on sample geometry.
Each researcher has unique needs and capabilities for their research, and not each mechanical testing method is possible for a given sample. As soft materials research continues to expand into more complex and biological systems that present additional challenges for reproducible measurements, building agreement around common synthetic soft materials is worthwhile for the community. By noting the current discrepancies in literature on PDMS and by advocating that work going forward place a greater emphasis on consistency and comparison to the full body of literature (not selected works that happen to align with ones results), we anticipate better agreement in measured mechanical properties is easily attainable and hope that this manuscript motivates this as a community goal.
Footnotes |
| † Electronic supplementary information (ESI) available: Details of original data published here for the first time, summary of all articles included across the meta-analysis, including interconnection mapping of citations. Additional details of regression analysis. See DOI: https://doi.org/10.1039/d4sm00573b |
| ‡ The exact composition of SYLGARD 184 is proprietary. Reading the product literature and safety data sheets provides the following insights.30,36–38 The base contains a majority dimethylvinyl-terminated dimethyl siloxane (>60%), with a significant portion of silica fillers (30–60% dimethylvinylated and trimethylated silica), as well as 1–5% tetra(trimethylsiloxy) silane and small amounts of ethylbenzene, xylene and a platinum catalyst (<1% each). The curing agent is a majority the cross linking agent dimethyl methylhydrogen siloxane (40–70%), additional methylated silica and siloxanes, and 1–5% the inhibitor tetramethyl tetravinyl cyclotetrasiloxane. |
| § This result can be obtained directly from eqn (1) at the limit λ → ∞, with a neo-Hookean form of W(λ), as shown in ref. 64. |
| ¶ The data displayed here from Liu et al.51 have been down selected to only the 100 °C and 200 °C data, though 150 °C and 300 °C cure temperatures were also evaluated in the original work. |
| This journal is © The Royal Society of Chemistry 2024 |