Open Access Article
Dorota Bartczak
a,
Aneta Sikora
a,
Heidi Goenaga-Infante
a,
Korinna Altmann
b,
Roland Drexelc,
Florian Meier
c,
Enrica Alasonatid,
Marc Lelongd,
Florence Cadod,
Carine Chivas-Jolyd,
Marta Faddae,
Alessio Sacco
e,
Andrea Mario Rossie,
Daniel Pröfrockf,
Dominik Wippermannf,
Francesco Barbero
g,
Ivana Fenoglio
g,
Andy M. Booth
h,
Lisbet Sørensenh,
Amaia Igartuah,
Charlotte Wouters
i,
Jan Mast
i,
Marta Barbaresij,
Francesca Rossi
k,
Maurizio Piergiovannij,
Monica Mattarozzij,
Maria Carerij,
Thierry Caebergs
l,
Anne-Sophie Piette
l,
Jeremie Parot
m and
Andrea Mario Giovannozzi
*e
aNational Measurement Laboratory, LGC Limited, 10 Priesley Road, Guildford, UG2 7XY, UK
bBundesanstalt für Materialforschung und – prüfung (BAM), Unter den Eichen, 87, Berlin, Germany
cPostnova Analytics GmbH, Rankinestr. 1, 86899 Landsberg a. Lech, Germany
dLaboratoire National de Métrologie et d'Essais (LNE), 1 rue Gaston Boissier, 75015 Paris, France
eIstituto Nazionale di Ricerca Metrologica (INRiM), Strada delle Cacce 91, 10135 Torino, Italy. E-mail: a.giovannozzi@inrim.it
fInstitute of Coastal Environmental Chemistry, Inorganic Environmental Chemistry, Helmholtz-Zentrum Hereon, Max-Planck Str. 1, 21502 Geesthacht, Germany
gDepartment of Chemistry, University of Torino, Torino, Italy
hDepartment of Climate and Environment, SINTEF Ocean, Trondheim, Norway
iTrace Elements and Nanomaterials, Sciensano, Groeselenberg 99, 1180 Uccle, Belgium
jDepartment of Chemistry, Life Sciences and Environmental Sustainability, University of Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy
kIMEM, CNR Institute of Materials for Electronics and Magnetism, Parco Area delle Scienze 37/A, Parma, 43124, Italy
lDG Quality and Safety, Metrology Division (SMD), FPS Economy, Bd du Roi Albert II, 16, 1000 Brussels, Belgium
mDepartment of Biotechnology and Nanomedicine, SINTEF Industry, Trondheim, Norway
First published on 4th February 2026
Reference and quality control materials with comparable physicochemical properties to nanoplastic contaminants present in environmental and food nanoplastics are currently lacking. Here we report a nanoplastic polypropylene material prepared using a top-down approach involving mechanical fragmentation of larger plastics. The material was found to be homogeneous and stable in suspension and has been characterised for average particle size, size distribution range, particle number concentration, polypropylene mass fraction and inorganic impurity content using a wide range of analytical methods, including AF4, cFFF, PTA, (MA)DLS, MALS, SEM, AFM, TEM, STEM, EDS, Raman, ICP-MS and pyGC-MS. The material was found to have a broad size distribution, ranging from 50 nm to over 200 nm, with the average particle size value dependent on the technique used to determine it. Particle number concentration ranged from 1.7–2.4 × 1010 g−1, according to PTA. Spectroscopy techniques confirmed that the material was polypropylene, with evidence of aging due to an increased level of oxidation. The measured mass fraction was found to depend on the marker used and ranged between 3 and 5 μg g−1. Inorganic impurities such as Si, Al, Mg, K, Na, S, Fe, Cl and Ca were also identified at ng g−1 levels. Comparability and complementarity across the measurement methods and techniques is also discussed.
Environmental significanceReliable reference and quality control materials are essential for advancing nanoplastics research, yet materials with properties comparable to those found in environmental and food samples remain scarce. In this work, we present a polypropylene nanoplastic material produced through mechanical fragmentation, providing a representative and well-characterised model for environmental contaminants. The material shows stability in suspension and has been comprehensively characterised for particle size, concentration, composition, and impurities using a wide range of state-of-the-art analytical methods. By offering a realistic, traceable, and versatile test material, this study supports improved method validation, comparability across laboratories, and more robust risk assessment of nanoplastics in environmental and food contexts. |
Despite joint international efforts to reduce the amount of plastic waste, it continues to be released into the environment at an unprecedented scale.3 Once in the environment, plastics undergo fragmentation upon exposure to UV radiation and through mechanical stress.4 Larger pieces of plastic are fragmented into microplastics (MPs), defined as particles in the size range from 1 μm to 1 mm5 or 5 mm,6 and eventually to nanoplastics (NPs), with sizes below 1000 nm.7 MPs and NPs have been reported in all environmental compartments, accumulating in soils and sediments, and considered critical persistent pollutants of increasing global concern owing to their high durability and long-life.8
The potential long-term impacts on biota and human health arising from MPs and NPs present in the environment are still unknown, and there are no defined maximum daily exposure limits due to the lack of robust toxicological data.9 This is, in part, due to the absence of metrologically validated, harmonised and standardised measurement methods, as well as the lack of consensus with regard to the typical quantities (per size class, especially for particles with sizes below 1000 nm) and physicochemical characteristics of various types of plastics typically occurring in the environment. There remains a need to develop robust analytical methods for plastic characterisation, especially at the sub-micron and nanoscale.
The characterisation and quantification of plastic particles <1000 nm is challenging due to their multimodal and polydisperse character and irregular shape, but also due to the limitations of analytical techniques routinely used for the characterisation of other types of particles in the size range from 1–1000 nm. For instance, commonly used light scattering techniques, such as dynamic light scattering (‘DLS’ or multi-angle DLS ‘MADLS’10), multi-angle static light scattering (MALS11) or particle tracking analysis (PTA12), as well as high-resolution microscopy methods, such as transmission electron microscopy (TEM13), scanning electron microscopy (SEM14) or atomic force microscopy (AFM15) are compatible with particles in that size range, but they cannot easily distinguish between plastic particles and other types of particles that might also be present in the sample.16 Conversely, spectrometry-based methods, such as pyrolysis gas chromatography-mass spectrometry (pyGC-MS), can distinguish plastic particles but do not provide information about particle size or morphology.16 Moreover, most of the imaging spectroscopy methods, such as micro-Raman (μRaman) or micro-Fourier transform infrared spectroscopy (μFTIR), have size detection limits >1000 nm and are therefore unable to characterise and quantify particles in the nanoscale.17
These limitations with individual techniques highlight the need for the development of alternative multi-technique, hyphenated (e.g. multidetector field-flow fractionation ‘FFF’16) or hybrid approaches (e.g. SEM/RAMAN,18 dielectrophoresis (DEP)-Raman19,20) involving a combination of measurement methods, allowing simultaneous characterisation of multiple parameters at the nanoscale, including chemical identity, particle size, and size distribution, as well as mass and number concentration. Such combined approaches will be invaluable in supporting policymakers, international standardisation efforts and testing laboratories, and will enable the development and characterisation of future NP quality control (QC) measures and reference materials (RMs), which are currently unavailable.
This work describes a systematic evaluation of the applicability of selected light scattering, fractionation, high-resolution microscopy, spectroscopy and spectrometry methods, as standalone techniques and in combination (including hyphenated and hybrid), for characterising plastic particles <1000 nm. Assessment was conducted using a combination of commercially available polystyrene (PS) microspheres and more environmentally relevant polypropylene (PP) nanoplastic particles produced through a top-down method. The complementarity and comparability of the different analysis techniques are discussed, including when applied in combination, along with main sources of measurement errors for selected techniques and measurands.
000 rpm after which the suspension was filtered through a pleated filter (Labsolute Partikelret. 5–8 μm, 100% cellulose) to remove larger particles. The particles on the filter were washed twice with 20 mL acetone. The volume of the resulting filtrate was then reduced to 10% (ca. 25 mL) by rotary evaporation (temperature water bath: 55 °C, pressure 510–530 mbar), before adding 250 mL of ultrapure water. The suspension was subjected to rotary evaporation again to remove the remaining acetone by reducing the pressure. After reaching a pressure of 100 mbar the conditions remain constant for another 30 min. Temperature of the water bath: 55 °C. The resulting aqueous suspension was filtered again via a clean, but similar, pleated filter. The final filtrate was divided into 890 brown glass vials, each containing ∼2 mL of PP suspension. The procedure described by Hildebrandt et al.21 was repeated by BAM approximately 60 times, using ∼6 g starting material. For the purpose of the work described here the amount of starting material was increased from 6 g to 25 g, however the resulting particles show comparable characteristics in terms of particle size distribution to the material described by Hildebrandt et al.21
![]() | ||
| Fig. 1 Fragmentation of PP pellets with UltraTurrax (left), filtration of fragmented PP for fractionation (centre) and the final bottled PP suspension (right).21 | ||
Since the candidate reference material and representative test materials are typically prepared as a single batch which is then portioned into multiple vials/containers, the homogeneity and stability of such materials are typically assessed based on between unit variability, as described in ISO 33405:2024. The homogeneity of the nanoPP material was investigated by analysing the content of 15 units in duplicate by PTA to determine particle size and number concentration (as described in section 2.2). Material stability was tested periodically using batch DLS analysis (as described in section 2.2) at time 0, 1 month, 3 months and 6 months, covering the period over which all measurements described in the work reported here were performed. Three bottles were measured in duplicate at each time point. All materials were diluted, as required by each technique, in ultrapure water (18.2 MΩ cm, 25 °C, Elga Purelab Chorus, Viola Water Technologies, Buckinghamshire, UK) prior to analysis, unless stated otherwise.
At Postnova Analytics, multi-detector (MD)-AF4 experiments were performed on an AF2000 MT system (Postnova Analytics, Landsberg a. L., Germany). An analytical AF4 channel with a tip-to-tip length of 277 mm, a width of 20 mm and a hip width of 5 mm was equipped with a regenerated cellulose membrane (RC) with a molecular weight cut-off of 10 kDa and a 350 μm spacer height. The temperature during fractionation was kept constant at 25 °C using a channel thermostat. The samples were injected using an autosampler. The fractionation system was directly coupled to a UV/Vis detector and a MALS detector (21 active angles, laser wavelength 532 nm). The UV absorbance was measured at 254 nm. The MALS detector was normalised using fractionated 60 nm PS beads and a spherical fit model. A volume of 20 μL of a 40 ppb nanoPP suspension was injected as received, with no sample preparation performed. The carrier liquid consisted of 0.2% (v/v) NovaChem100 (PN). For the fractionation, a detector flow rate of 0.50 mL min−1, an injection flow rate of 0.20 mL min−1 and an injection time of 5 min were applied. The initial cross flow rate was set to 1.20 mL min−1. After a transition time of 0.2 min, the cross-flow rate was kept constant for 0.2 min and then decreased within 40 min using a power decay (exponent = 0.2) to 0.10 mL min−1. This last cross flow rate was kept for 10 min, followed by a rinse step of 5 min. All measurements were conducted in duplicate. In total, 12 vials (each with 2 aliquots) were fractionated and characterised. MALS data evaluation was performed within an angular range of 12° to 156°, and the scattering intensities were evaluated by fitting a sphere model to the angular dependent scattering data to obtain size information (radius of gyration, Rg). This type of fit model yielded results with low deviations across the complete size range with squared correlation coefficients above 0.98. The sphere model represented the data points accurately around the peak maximum. Slight deviations for the smallest and largest size fractions were observed, but comparable results were derived from a fourth order polynomial fit. The system was controlled by the NovaFFF Software (version 2.2.0.1) and data evaluation was performed in the NovaAnalysis software (version 2408).
At LNE, MD-AF4 analysis was performed on an AF4 system (AF2000 Postnova Analytics) coupled to MALS (DAWN HELEOS II, Wyatt Technology) equipped with 18 angles and UV (SPD-20A, Shimadzu) detectors. A metal-free analytical AF4 channel (tip-to-tip length of 277 mm, 20 mm width and 5 mm hip width) (Postnova Analytics) was used. The carrier liquid was prepared by dissolving Novachem100 (Postnova Analytics) in ASTM type I ultrapure water to a final concentration of 0.0125% and passing through a 0.1 μm filter (RC, Postnova Analytics). The channel out-let flow rate was 0.5 mL min−1. MALS data treatment was performed using the Berry model of second degree, 11 angles and the Astra Software (version 6.1.7, Wyatt Technology). The UV detector was used for MALS data treatment and for recovery calculation. The uncertainty associated with the Rg was established as the combination of the repeatability, the average MALS model uncertainty and the size bias between the certified value and the measured value of a 200 nm PS standard. Blanks consisting of pure carrier liquid were injected between samples and no carry over was observed. Aliquots of the nanoPP suspension were characterised without any dilution or further sample treatment (e.g. filtration or ultrasonication).
At SMD, MD-AF4 analysis was performed on a Wyatt Eclipse DualTec, equipped with a UV/Vis detector (Agilent G7114A), a MALS detector (DAWN HELEOS II, Wyatt Technology), and an inline Malvern Zetasizer Nano ZS (Malvern Panalytical, UK). The carrier was SDS (0.01% m/v) in ultrapure water, filtered through a 0.1 μm filter (RC, Millipore). The separation method was an isocratic program for most of its duration and separation. The UV/Vis wavelength was set to 200 nm, and blank subtraction applied.
At the University of Parma, TEM analysis was performed using a JEOL JEM-2200FS field-emission microscope equipped with an EDX detector (Oxford Xplore), operated at an accelerating voltage of 200 kV.25,26 Ultra-thin carbon-coated copper grids (200 mesh, Electron Microscopy Society) were selected to provide optimal support. The images were recorded in both TEM imaging mode using a Gatan UltraScan US1000 camera and in STEM imaging mode using a HAADF detector. For each grid, 20 micrographs were acquired in random sampling mode, ensuring coverage of both the border and centre regions of the grid. Ultrapure water blanks were analysed to detect any potential contamination introduced during sample preparation and handling. Particle counting and sizing were performed using the open-source ImageJ software. The intensity range was adjusted to isolate particles from the background. To improve particle separation and minimise noise, manual thresholding and morphological filtering were applied. Sample preparation was performed in a cleanroom (ISO level 6) to minimise cross-contamination. Glassware was pre-cleaned according to the internal standard operating procedure developed within the PlasticTrace project, involving a sequential washing and sonication for at least 5 minutes using TritonX-100 (0.1 mg L−1), acetone and an isopropanol/water solution (20% v/v). A suspension of the 200 nm PS QC material was diluted in ultrapure water to a final concentration of 0.04 mg mL−1. A 20 μL aliquot of the suspension was then drop-cast on the TEM grid and dried at room temperature. Three different sample preparation protocols were tested using nanoPP suspensions at a nominal concentration of 0.04 mg mL−1. (i) Drop-casting: an aliquot of 100 μL of the nanoPP suspension was dried in a clean vial at 50 °C, reconstituted with 30 μL of ultrapure water, dried again, and reconstituted with an additional 10 μL of ultrapure water. The final suspension was then drop-cast on the TEM grid and dried at room temperature. (ii) Concentration by heating bath: 100 μL of the nanoPP suspension was placed directly into a vial containing the TEM grid and dried at 50 °C using a hot bath. Subsequently, the sample was reconstituted with 30 μL of ultrapure water directly over the grid and dried again. (iii) Concentration by SpeedVac, drying and drop-casting: 2 mL of the nanoPP suspension was dried at 50 °C using a SpeedVac system. The sample was reconstituted with 30 μL of ultrapure water, dried again, and reconstituted with an additional 10 μL of ultrapure water. The final suspension was then drop-cast on a TEM grid and dried at room temperature.
At LNE, a drop of the nanoPP suspension was deposited on a silicon wafer and identified by using μRaman (LabRAM Soleil™ Confocal Raman Microscope) equipped with LabSpec 6 software. Raman spectra were acquired using a 532 nm laser at 50% power, with a 200 μm aperture and a 600 lines per mm grating (500 nm). The exposure time was set to 1 s with 10 accumulations. Measurements were performed using a 100× objective over a spectral range of 500–3500 cm−1. The resulting spectra were compared with the IDFinder spectral library for particle identification.
:
1. The carrier gas was helium at a constant flow of 1 mL min−1. Separation was achieved using a Frontier Ultra ALLOY+-5 capillary column (30 m length, 0.25 μm film thickness, and 0.25 mm internal diameter). The column oven temperature was programmed at 40 °C (2 min) and ramped up by 20 °C min−1 until it reached 320 °C (25 min hold). The transfer line temperature was 320 °C, the ion source temperature was 230 °C, and the quadrupole temperature was 150 °C. The ion source was operated in SIM mode using several established target peaks for quantification of PP: 2,4-dimethylhept-1-ene using marker ions m/z 70 and 126; 2,4,6-trimethyl-1-nonene (meso) and 2,4,6-trimethyl-1-nonene (racemic) using marker ions m/z 69 and 97; 2,4,6,8-tetramethyl-1-undecene (isotactic), 2,4,6,8-tetramethyl-1-undecene (heterotactic) and 2,4,6,8-tetramethyl-1-undecene (syntactic) using marker ions m/z 69 and 111. External calibration curves were prepared from an in-house standard PP reference material by complete solvent dissolution and subsequent dilution to different concentrations. For calibration, a standard PP powder (PP Co-polymer CRT201.00 from CARAT GmbH, <100 μm) was dissolved in xylene (130 °C, 30 min followed by ultrasonication in a sonication bath, 10 min 80 °C), diluted and spiked in resulting masses of 0.25–5 μg in stainless steel pyrolysis cups. Samples were run in randomised order, with triplicate calibration samples run throughout the series, also in randomised order. It is important to note that the PP powder used for calibration was not produced from the same PP pellets used to generate the nanoPP test material (section 2.1.2).
000 μg L−1 for Si, P, Mg, Al, K, Ca, Ti and Mn automatically diluted by the prepFAST M5 system from two stock solutions (500 μg L−1 and 10
000 μg L−1), as well as online dosed internal standards (10 μg L−1 Rh and Ir) were used for quantification. Potential carry-over effects were monitored by measuring wash blanks (2% HNO3 (w/w)) after each triplicate of samples. Calibration solutions were freshly prepared immediately before measurement.At Postnova, AF4/MALS/ICP-MS measurements were performed using an AF4 system, as described under 2.2.3, that was hyphenated to ICP-MS (7900 ICP-MS, Agilent Technologies Inc. USA). The hyphenation was realised using an ICP-MS module (PN 9040), which connected the MALS detector outlet with a T-piece connected to the ICP-MS. Sample introduction on the ICP-MS system consisted of a MicroMist nebuliser and a concentric Scott spray chamber. A plasma gas flow rate of 15 L min−1 and a nebuliser gas flow rate of 1.05 L min−1 were applied. All measurements were conducted at a maximum radio frequency power of 1550 W. A collision gas of 4.5 mL min−1 of helium was introduced into the collision cell to remove potential polyatomic interferences. The ICP-MS performance was checked and tuned prior to the measurements. The isotopes 24Al, 27Al, 28Si, 31P, 35Cl, 38Ca, 47Ti, 52Cr, 56Fe, 60Ni, 63Cu, 66Zn, 79Br, and 90Zr were monitored with an integration time of 0.1 s. The carrier liquid consisted of 0.0125% (v/v) NovaChem100 and the same fractionation method was used as described under 2.2.3. The injection volume was increased to 100 μL. A 200 nm PS bead with a maximum injection amount of 4 μg was used as a control.
This material, like majority of other reference materials and representative test materials, was prepared as a single batch, which was then portioned into multiple vials/containers. The homogeneity and stability of this material were hence assessed based on between unit variability, as described in ISO 33405:2024. The PTA technique was chosen for the purpose of the nanoPP material's homogeneity assessment as it allows determination of hydrodynamic size and particle number concentration independent from each other, which are considered critical measurands for particles at the sub-micron and nanoscale. For particle size, the modal particle size was evaluated. The size was less variable than particle number concentration, with no clear outliners detected for either of the two measurands. For the modal particle size, uncertainty associated with homogeneity was around 4.4%. In the case of particle number concentration, this value was around 14.4%.
The material's stability was tested using DLS, since this light technique is more sensitive to the presence of agglomerates/aggregates (a strong indicator of particle instability) than number-based methods such as PTA. DLS provides information on particle size and size distribution. No significant differences in particle size and particle size distribution were observed over a 6-month period.
![]() | ||
| Fig. 2 Average size distribution graphs obtained with PTA using NanoSight NS300 (black line) and PMX-120 (red line). | ||
| Institute | Instrument | nanoPP particle mean size (nm) | ||
|---|---|---|---|---|
| Average (nm) | Stdev (nm) | RSD (%) | ||
| LGC | NanoSight NS300 | 148.1 (n = 45) | 5.5 (n = 45) | 4.0 |
| Postnova | NanoSight NS300 | 147.0 (n = 24) | 3.5 (n = 24) | 2.4 |
| UNITO | PMX-120 | 170.4 (n = 15) | 4.4 (n = 15) | 2.6 |
As can be seen in Fig. 2 (black line), the size distribution of the particles in the nanoPP material determined by the NanoSight NS300 instruments suggests a polydisperse distribution with multiple modes and broad size distribution tailing towards larger sizes. This is consistent with a material produced via a top-down approach using mechanical fragmentation and sieving to increase the environmental relevance. The size distribution for the PMX-120 instrument (red line) is shifted towards larger sizes, which might be related to effects arising from the data processing algorithms the two different instruments use. Due to the multimodal and polydispersed character of the nanoPP material, the mean particle size rather than the modal particle size is considered the most appropriate and more practical measurand for the purpose of comparison with intensity-based methods (like DLS) described in the following sections. Even in this case, the mean particle size value measured by the PMX-120 instrument is slightly larger (170.4 nm) than the values determined by the NanoSight NS300 instruments (147.0 and 148.1 nm). However, if expanded measurement uncertainty (k = 2), calculated as being ∼10–11% according to Eurachem/CITAC guidelines, is considered for the purpose of data comparison, the results obtained across all three instruments are in agreement within the associated measurement uncertainty. Measurement repeatability was identified as being the main factor (∼50% of the uncertainty budget) contributing to the overall uncertainty, as expected for a polydisperse material. The size obtained for the PS QC material was 201.4 ± 2.9 nm (LGC), 195.4 ± 2.2 nm (Postnova) and 204.4 ± 1.5 nm (UNITO), in agreement with the size value reported by the manufacturer (202 ± 4.0 nm) and consistent across all experimental set-ups tested.
The particle size and size distribution of the nanoPP suspension were also measured with MADLS by LGC and batch DLS by INRIM. The results are presented in Table 2 as average mean size values (MADLS) or average hydrodynamic diameter (z-average; DLS), with associated standard deviation of n measurements. Mean particle size was similar for both DLS (174.9 ± 0.4 nm) and MADLS (186.0 ± 3.9 nm), with the slight difference between the two values suggested to be a result of data processing algorithms, being the cumulants method in the case of DLS and the distribution algorithm, or so called ‘multiple narrow mode’, for MADLS. The cumulants model assumes a single particle population, which is represented as a simple Gaussian distribution, with the z-average being the mean size value. In contrast, the distribution algorithm models the correlogram as an intensity contribution for each size band/bin. As such, the cumulants model for a material exhibiting a polydisperse non-Gaussian distribution, as in the case of the nanoPP material, might give different results than MADLS. As both DLS and MADLS are intensity-based methods, they are more sensitive to the presence of larger particles than number-based methods such as PTA, which results in the slightly larger mean particle size for the former.
| Institute | Particle mean or z-average size (nm) | ||
|---|---|---|---|
| Average (nm) | Stdev (nm) | RSD (%) | |
| LGC (MADLS) | 186.0 (n = 41) | 3.9 (n = 41) | 2.1 |
| INRIM (DLS) | 174.9 (n = 15) | 0.4 (n = 15) | 0.2 |
The results obtained by the different FFF-based methodologies are summarised in Table 3. The AF4-MALS measurements performed by Postnova on the nanoPP suspension showed excellent repeatability, with a mean retention time of 26.71 ± 0.34 min (n = 24) (Fig. 3). The peak width and peak shape across all investigated aliquots were very comparable, with insignificant field-off and void peaks. The average MALS 90° signal across all measurements is displayed in black, and the grey area visualises the standard deviation of the MALS 90° signals. As the retention time is directly proportional to the particle hydrodynamic size, the size can be derived using FFF theory. The derived weight-average Rg,w of 75.0 nm ± 0.9 nm (mean ± stdev, n = 48) is equivalent to a sphere with a diameter of 194 nm. The mean particle size derived from angular dependent MALS signal intensities yielded an Rg,50 = 74.2 nm ± 0.8 nm (mean ± stdev, n = 48), which is equivalent to a geometrical sphere with a diameter of 191 nm. Both values are in good agreement with FFF theory and PTA and DLS results.
| Institute | Set-up | Radius | Rn | Rw | Rz | R50 | System recovery (%) | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Mean ± stdeva (nm) | u, k = 1 (%) | Mean ± stdeva (nm) | u, k = 1 (%) | Mean ± stdeva (nm) | u, k = 1 (%) | Mean ± stdeva (nm) | u, k = 1 (%) | ||||
| a n (number of replicate measurements) is given in the Experimental, Results and/or SI sections. | |||||||||||
| Postnova | AF4-MALS 90° signal | Hydrodynamic | 102.5 ± 2.1 | 2.0 | 98.2 ± 1.7 | 1.7 | >75 | ||||
| Postnova | AF4-MALS | Gyration - sphere | 46.3 ± 3.8 | 8.2 | 75 ± 0.9 | 1.2- | 96.3 ± 3.6 | 3.7 | 74 ± 0.8 | 1 | >75 |
| LNE | AF4-UV-MALS | Gyration | 81 ± 4a | 5 | 86 ± 4a | 5 | 91 ± 5a | 6 | — | — | ∼74 |
| SMD | AF4-UV-MALS | Gyration - | 64 ± 10 | 16 | 92 ± 3 | 3 | 111 ± 2 | 1 | — | — | > 70 |
| Hereon | cFFF-MALS | Gyration - | 65 ± 5 | 8 | 67 ± 5 | 7 | 69 ± 5 | 7 | — | — | > 70 |
At LNE, six replicates of each nanoPP vial were analysed on two different days to include daily variability in the measurement precision. The results of the characterisation show excellent repeatability (Table 3), but the Rg values obtained using MALS were slightly larger than obtained on the different instrumental set-up at Postnova. Nonetheless, if measurement uncertainties (k = 1) are considered, the results are in agreement within the associated errors. They also agree with PTA and MADLS data. It is also important to mention that channel recoveries of > 70% were obtained using the AF4-based method (meeting method acceptance criteria described in ISO 21362 (ref. 29)). Similar results were obtained at SMD (Table 3 and SI, section E). At Hereon, 4 replicates of each nanoPP vial were analysed using cFFF coupled to MALS. Rg values obtained with this instrumental set-up were in agreement with values reported for AF4 (see SI, section F, for details). It is also important to mention that channel recoveries of >70% were obtained at all labs and with all systems, meeting method acceptance criteria described in ISO 21362.29
SEM-EDX was used to obtain size and size distribution data on nanoPP, as well as elemental information. Representative SEM images shown in Fig. 4 reveal that the nanoPP material comprised particles with irregular shapes and a broad size distribution, ranging from ∼50 nm to ∼160 nm and a modal size of ∼93.9 nm (with standard measurement uncertainty k = 1 of 2.3 nm). The EDX spectrum of the imaged particle population in the nanoPP sample revealed clearly visible peaks relating to the oxygen O Ka line (Fig. 5). The observable S Ka signal potentially comes from the isotactic form of the PP polymer, with cross linkage in the presence of sulphur.30 The copper peak Cu La and the carbon peak C Ka come from the substrate (carbon and pioloform coated Cu grid) used to deposit the particles, whilst the Al Ka signal comes from the sample holder.
![]() | ||
| Fig. 4 Representative SEM images of particles present in the nano-PP sample with magnification ×10 000 for the image on the left and magnification ×100 000 for the image on the right. | ||
![]() | ||
| Fig. 5 EDX spectrum obtained for the selection of particles present in the nanoPP sample as indicated on the SEM image (right) and EDX mapping in the same area (left). | ||
STEM-EDX analysis of the nanoPP material, deposited by various methods, revealed the presence of several chemical compounds (mostly salts and other inorganic compounds, see SI, section F). The particles are suspended in water. Even if MilliQ water was used, it seems reasonable to assume that the salts originated from the PP raw material or the material processing to derive the nanoPP suspension, rather than the water dispersant itself. Grids prepared by grid-on-drop deposition and using Alcian blue grid staining resulted in the least amount of interference of various deposited compounds. From such a grid, a size histogram of area-equivalent circular diameter (ECD) was constructed based on the manual measurement of 74 particles, resulting in a mean ECD of 166 nm (SI, section F, Fig. 1), consistent with the results from characterisation techniques able to analyse the particles in suspension. The limited statistics reflect the low particle concentration on the grid. While most particles were isolated, a few agglomerates were also observed, in which case constituent particles that could be resolved visually were measured individually. The composition of a subset of particles was verified by STEM-EDX to be sure that the C signal, indicative of plastic composition, was dominating. However, since C is also present in the supporting film, it cannot be said with certainty that the particles included in the size analysis are nanoPP.
SI, section E, gives an overview on how to validate TEM for reliable determination of particle size and shape based on the 200 nm PS QC material. It demonstrates that accurate and precise measurements can be obtained for monomodal and monodispersed nanoplastic particles, when the particle concentration is sufficiently high. In contrast, attempts to measure the size of nanoPP demonstrate that detection and analysis of environmentally relevant nanoplastics with TEM is much more challenging. Currently, there is no reliable method to selectively separate and enrich nanoplastics with low abundancies to enable analysis in the same way as QC materials. While analytical TEM, such as STEM-EDX, can be useful for detecting false-positive plastic identifications through elemental composition analysis and thus serve as a complementary technique to DLS and PTA, it cannot directly confirm the presence of plastics. Analysis of the nanoPP material by STEM-EDX at the University of Parma TEM produced results that were in agreement with those described above (see SI, section G).
With (classical) AFM performed at SMD only mechanical measurement was possible. Reliable dimensional measurement was achieved by using the deposition method described in the Results section, which yielded a sufficient amount of particles without visible agglomeration. Overall, the size range measured with AFM was in agreement with the size reported by SEM and TEM (see SI, section H for details).
The results of nanoPP size characterisation with the techniques described above are summarised in Fig. 6, where blue markers highlight techniques providing hydrodynamic diameter, yellow markers represent techniques providing geometric size, whilst a green marker is an equivalent modal size from the surface area (obtained via SEM), which all represent different measurands (although all size related) and hence cannot be compared like-for-like. Typically, hydrodynamic diameter is larger than geometric size, which in turn is larger than equivalent size obtained from electron microscopy techniques representing the particle core only, and not accounting for a hydration layer or surface bound ligands or stabilisers. Furthermore, whilst AF4, CF3, DLS/MADLS and PTA results represent mean particle size, SEM results show modal particle size, which for polydispersed particles with non-Gaussian tailing distribution can indeed be larger. In the case of PTA (LGC results) the same data sets with a mean particle size of 148.1 ± 5.5 nm (average ± stdev, n = 45) would give a modal particle size value of 118.2 ± 15.1 nm (average ± stdev, n = 45), being much closer to the SEM result. Another point to consider is weighting of the results, whilst PTA and SEM represent number-weighted particle size, DLS and MADLS are intensity weighted, hence predominantly influenced by the presence of larger particles, resulting in larger size, especially for polydispersed materials, like nanoPP. It is also important to mention that the difference in size reported here between techniques could also be additionally exaggerated by between lab variability, which was not studied as part of the work reported here.
| Institute | Particle number concentration (g−1) | ||
|---|---|---|---|
| Average (g−1) | Stdev (g−1) | RSD (%) | |
| Postnova | 1.73 × 1010 (n = 24) | 2.47 × 109 (n = 24) | 14.3 |
| LGC | 2.04 × 1010 (n = 45) | 1.78 × 109 (n = 45) | 8.7 |
| UNITO | 2.4 × 1010 (n = 15) | 2.6 × 109 (n = 15) | 10.8 |
O) peaks at 1650 cm−1 and 1605 cm−1 indicate partial oxidation of the PP surface, facilitated by acetone's role as a swelling agent that exposes amorphous regions to atmospheric oxygen, with shear forces from Ultraturrax accelerating reactive species formation (e.g., peroxides leading to ketones/carboxylic acids).33,34 In the fingerprint region, shifts such as 1436 → 1445 cm−1 (CH2 bending), 1254 → 1277 cm−1 (CH3 rocking), and others (1219 → 1202, 1168 → 1157, 1153 → 1127, 940 → 929 cm−1) arise from lattice contraction and amorphization upon nanosizing, reducing peak resolution and intensities while eliminating crystalline-sensitive bands at 842 cm−1 and 810 cm−1 (replaced by a broader 830 cm−1 feature). These modifications confirm nanoPP's chemical identity as oxidized polypropylene, with differences stemming from preparation-induced aging rather than phase transformation (Fig. 7).19
![]() | ||
| Fig. 7 Raman spectra (from bottom to top) of bulk PP, nanoPP with DEP off (background), and nanoPP with DEP on. | ||
Correlative SEM/Raman analysis was also performed on a drop of the nanoPP suspension deposited on a silicon wafer to assess the global chemistry. As chemical analysis of individual nano-scale particles by Raman is not possible due to the limited size resolution of this technique in the nanometer size regime, bulk analysis can be used to generate an average spectrum. The collected spectra confirmed the material was PP and were in agreement with data obtained by INRiM (see SI, section I for details).
| Marker | nanoPP (μg mL−1) | Blank (μg mL−1) | ||||
|---|---|---|---|---|---|---|
| Average | Stdev | RSD (%) | Average | Stdev | RSD (%) | |
| Sum 2,4,6-trimethyl-1-nonene | 5.0 | 1.1 | 22 | 0.71 | 0.02 | 2 |
| Sum 2,4,6,8-tetramethyl-1-undecene | 4.3 | 1.0 | 24 | 0.66 | 0.01 | 2 |
| 2,4-Dimethylhept-1-ene | 2.7 | 0.5 | 19 | 0.79 | 0.01 | 1 |
| 2,4,6-Trimethyl-1-nonene (meso) | 3.5 | 0.7 | 20 | 0.75 | 0.01 | 1 |
| 2,4,6-Trimethyl-1-nonene (race) | 9.5 | 2.1 | 22 | 0.73 | 0.01 | 1 |
| 2,4,6,8-Tetramethyl-1-undecene (iso) | 2.8 | 0.6 | 23 | 0.74 | 0.01 | 1 |
| 2,4,6,8-Tetramethyl-1-undecene (het) | 17 | 4 | 22 | 0.5 | 0.2 | 30 |
| 2,4,6,8-Tetramethyl-1-undecene (syn) | 3.7 | 0.8 | 22 | 0.76 | 0.01 | 1 |
While it is possible that the nanoPP production process may have caused fragmentation-induced chain scission and oxidation, possibly exacerbated by acetone exposure, the reference PP powder used for calibration and quantification was also produced via a harsh cryo-milling process. It therefore appears most likely that the observed differences in the pyrolysis marker ratios in the pyrograms of the two materials are the result of the differences in the composition of the two different sources of pellets used in their production (SI, section J). These differences in chemical composition between the PP reference material and the nanoPP (produced from a different PP source material) highlight a potential challenge with PP quantification by pyGC-MS. In environmental or human samples, the type of PP present cannot be known and maybe a mixture of different PP particles, meaning the use of a single PP reference material for generating calibration curves could easily over- or underestimate the true PP concentration.
All authors reviewed and approved the final version of manuscript.
| This journal is © The Royal Society of Chemistry 2026 |