Issue 9, 2019

Non-invasive monitoring of a circadian relevant biomarker from easily accessible body fluids using hybrid aqueous–ionic buffer interfaces on flexible substrates

Abstract

Frequent shift work causes disruption of the circadian rhythm and could potentially, in the long run, result in increased health risks. Current biomarkers evaluating the presence of circadian rhythm disturbance include melatonin, cortisol, and body temperature. These require 24 h or “around the clock” measurements, which is tedious. There is an immediate and unmet need to design non-invasive diagnostic sensors for rapid and continuous monitoring of biomarkers associated with circadian rhythm cycles. We have evaluated three biofluids that can enable non-invasive sampling which are sweat, urine and saliva. All the three biofluids have pH variability that typically impacts the sensor performance. In this paper, we demonstrate a hybrid flexible biosensor comprised of an aqueous and ionic interface integrated onto metallic gold microelectrodes for rapid and noninvasive monitoring of cortisol. We show that BMIM[BF4], a room temperature ionic liquid, can be used to modulate pH instability, as well as variations to the ionic content in the aqueous ionic buffers of sweat, urine, and saliva. We have demonstrated the stability of this sensor over the pH range of 4 through 8 in synthetic sweat, saliva, and urine. This detection was tested over a linear dynamic range in the physiologically relevant ranges of cortisol in these bio-fluids. Our facile approach addresses the challenges associated with the variability of body buffer chemistry and its impact on monitoring circadian rhythm.

Graphical abstract: Non-invasive monitoring of a circadian relevant biomarker from easily accessible body fluids using hybrid aqueous–ionic buffer interfaces on flexible substrates

Supplementary files

Article information

Article type
Paper
Submitted
30 Du 2018
Accepted
28 Gen. 2019
First published
06 Cʼhwe. 2019

Anal. Methods, 2019,11, 1180-1191

Non-invasive monitoring of a circadian relevant biomarker from easily accessible body fluids using hybrid aqueous–ionic buffer interfaces on flexible substrates

S. Upasham, S. Bhadsavle and S. Prasad, Anal. Methods, 2019, 11, 1180 DOI: 10.1039/C8AY02620C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements