Issue 11, 2023

Comparison of synthetic zircon, high-temperature and high-pressure sintered zircon and fast hot-pressing sintered zircon for in situ hafnium isotope analysis by LA-MC-ICP-MS

Abstract

This study compares three zircon synthesis techniques (synthesis, high-temperature and high-pressure sintering and fast hot-pressing sintering) for the preparation of reference materials for Hf isotope analysis of zircon by laser ablation multi-collector inductively-coupled plasma mass spectrometry (LA-MC-ICP-MS). Ultrafine milled zircon powder particles doped with Yb2O3 produced by wet milling were used to synthesize zircon samples by using high-temperature and high-pressure sintering and fast hot-pressing sintering techniques. Li–Mo flux was necessary to obtain synthetic zircon grains. Zr signals for synthetic zircon grains and high-temperature and high-pressure sintered zircon are consistent with those of natural zircons but higher than that of fast hot-pressing sintered zircon, indicating that high-temperature and high-pressure sintered zircon has approximated the theoretical maximum density due to high pressure. The Hf isotopic compositions of high-temperature and high-pressure sintered and fast hot-pressing sintered zircon are comparable to those of the initial starting materials, whereas the Hf isotopes in synthetic zircon grains deviate slightly from those of the initial Hf solution. Compared with Hf isotope ratios obtained by SN-MC-ICP-MS, all preparation techniques give reliable LA-MC-ICP-MS results, suggesting that all synthetic zircon samples have great potential as both tools for in situ method development and isotopic reference materials.

Graphical abstract: Comparison of synthetic zircon, high-temperature and high-pressure sintered zircon and fast hot-pressing sintered zircon for in situ hafnium isotope analysis by LA-MC-ICP-MS

Supplementary files

Article information

Article type
Paper
Submitted
28 Ebr. 2023
Accepted
18 Gwen. 2023
First published
18 Gwen. 2023

J. Anal. At. Spectrom., 2023,38, 2313-2323

Comparison of synthetic zircon, high-temperature and high-pressure sintered zircon and fast hot-pressing sintered zircon for in situ hafnium isotope analysis by LA-MC-ICP-MS

Z. Bao, K. Chen, L. Kang, C. Zong, X. Nie, N. Lv, P. Liang and H. Yuan, J. Anal. At. Spectrom., 2023, 38, 2313 DOI: 10.1039/D3JA00137G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements