Issue 18, 2023

A ratiometric electrochemical sensor for detecting lead in fish based on the synergy of semi-complementary aptamer pairs and Ag nanowires@zeolitic imidazolate framework-8

Abstract

This work describes the synergistic application of semi-complementary aptamer pairs and signals on–off ratio strategies on glassy carbon electrodes (GCE) for detecting lead ions (Pb2+) in fish. Gold nanoparticles (AuPNs) as the electrode substrate can provide added binding sites for the aptamers and improve the conductivity of the electrodes. Pb2+ aptamers containing ferrocene (Fc) molecules act as molecular recognizers in the sensing system. In the presence of target ions, Fc signals are affected by conformational changes of the aptamer. The “Ag nanowires@zeolitic imidazolate framework-8 with methylene blue (AgNWs@ZIF-8/MB)” can be semi-complementary to the Pb2+ aptamer after binding to single-stranded DNA (S1). However, S1/AgNWs@ZIF-8/MB self-assembled with Pb2+ aptamer (Apt) by hybridization incubation was quickly replaced by Pb2+ competitively, resulting in the loss of methylene blue (MB) signaling molecules. Hence, the internal reference signal (MB) and conformation change signal (Fc) comprise the ratio sensing system well. Morphology, spectroscopy, and electrochemistry methods have validated the modification and sensing behaviors. The used Apt has made considerable progress in analytical performance. In interference studies and stability checks, the ratio measurement signal IFc/IMB is a more reliable signal than the single signal readout. Following a log-linear relationship, this sensor provides a wide linear range. Furthermore, the proposed sensor can be used to determine Pb2+ in fish samples, and the results agree with those obtained using ICP-MS and recovery tests.

Graphical abstract: A ratiometric electrochemical sensor for detecting lead in fish based on the synergy of semi-complementary aptamer pairs and Ag nanowires@zeolitic imidazolate framework-8

Supplementary files

Article information

Article type
Paper
Submitted
07 ফেব্রু. 2023
Accepted
15 এপ্রিল 2023
First published
17 এপ্রিল 2023

Anal. Methods, 2023,15, 2199-2209

A ratiometric electrochemical sensor for detecting lead in fish based on the synergy of semi-complementary aptamer pairs and Ag nanowires@zeolitic imidazolate framework-8

K. Han, L. Chen, W. Zhang, Y. Tong, J. Shi, X. Su and X. Zou, Anal. Methods, 2023, 15, 2199 DOI: 10.1039/D3AY00196B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.