Issue 26, 2024

Metal–organic framework-interfaced ELISA probe enables ultrasensitive detection of extracellular vesicle biomarkers

Abstract

The enzyme-linked immunosorbent assay (ELISA) remains the prevailing method for quantifying protein biomarkers. Enzymatic signal generation and amplification are key mechanisms that govern its analytical performance. This study reports the synthesis and application of microscale metal–organic framework (MOF)/enzyme composite particles as a novel detection probe to substantially enhance the sensitivity of ELISA. An optimal one-pot approach was established to incorporate a substantial amount of streptavidin-horseradish peroxidase (SA-HRP) either within or on the surface of the metal-azolate framework (MAF-7) microparticles. This approach enables the labeling of a single sandwich antibody–antigen complex with numerous enzymes, which markedly amplifies the enzymatic colorimetric signal generation. Moreover, MAF-7 caging was found to enhance the reactivity of the caged HRP enzyme, further promoting the overall detection sensitivity of ELISA. Compared to other developments that are often associated with more complicated detection modalities, our method is compatible with standard immunoassays and commonly used photometrical signal detection. The implementation of this strategy in the detection of CD147 results in a remarkably low limit of detection of 2.8 fg mL−1, representing a 105-fold improvement compared to that obtained with the standard ELISA. Moreover, the heightened sensitivity of this technique renders it particularly suitable for diagnosing breast cancer, thus presenting a promising tool for the early detection of the disease in clinical settings.

Graphical abstract: Metal–organic framework-interfaced ELISA probe enables ultrasensitive detection of extracellular vesicle biomarkers

Supplementary files

Article information

Article type
Paper
Submitted
20 мар 2024
Accepted
28 май 2024
First published
28 май 2024

J. Mater. Chem. B, 2024,12, 6342-6350

Metal–organic framework-interfaced ELISA probe enables ultrasensitive detection of extracellular vesicle biomarkers

J. Shi, S. C. Barman, S. Cheng and Y. Zeng, J. Mater. Chem. B, 2024, 12, 6342 DOI: 10.1039/D4TB00585F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements