A sensitive and quantitative sandwich electrochemical immunosensor was constructed for the detection of Escherichia coli O157:H7 (E. coli O157:H7) using immune gold@platinum nanoparticles (Au@Pt), neutral red (NR), reduced graphene oxide nanocomposite (rGO) and regenerative leucoemeraldine base polyaniline (PANI)/gold nanoparticles (AuNPs) modified screen-printed carbon electrode (SPCE). The batch production advantages of the SPCE were retained, its disposable characteristic was replaced by the possibility for reuse. The anti-E. coli O157:H7 monoclonal antibody (Ab1) was automatically adsorbed on the SPCE-PANI-AuNPs platform through the amino and AuNPs interaction. rGO-NR-Au@Pt as the non-enzyme signal label can enhance the performance of the immunoassay for the catalytic reduction of H2O2 and amplify the current signal. All characterization steps were monitored by cyclic voltammetry (CV). Based on electrochemical detection of E. coli O157:H7, the linear range was from 8.9 × 103 to 8.9 × 109 CFU mL−1, and limit of detection (LOD) was 2.84 × 103 CFU mL−1. To ensure that the immunosensor can be used repeatedly, ultrasound sonication was used to remove as many surface-bound antibodies as possible. This allows Ab1 to bind to the SPCE-PANI-AuNPs again after the electrode was re-incubated with the antibody solution, and hence, the displacement assay can be repeated and the sensor reused. Furthermore, it was demonstrated that the microchips can be regenerated and reused at least 5 times.

Graphical abstract: A sensitive and regenerative electrochemical immunosensor for quantitative detection of Escherichia coli O157:H7 based on stable polyaniline coated screen-printed carbon electrode and rGO-NR-Au@Pt

Supplementary files

Article information

Article type
Paper
Submitted
28 ное 2018
Accepted
10 яну 2019
First published
12 яну 2019

Anal. Methods, 2019,11, 1475-1482

A sensitive and regenerative electrochemical immunosensor for quantitative detection of Escherichia coli O157:H7 based on stable polyaniline coated screen-printed carbon electrode and rGO-NR-Au@Pt

X. Mo, Z. Wu, J. Huang, G. Zhao and W. Dou, Anal. Methods, 2019, 11, 1475 DOI: 10.1039/C8AY02594K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements