Issue 8, 2018

Feasibility of As, Sb, Se and Te determination in coal by solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry

Abstract

In this work, a method for the determination of As, Sb, Se and Te in mineral coal was developed using solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry (SS-ETV-ICP-MS). The following operational parameters of the ETV-ICP-MS system were evaluated: the furnace temperature program, the mass of Ir used as the modifier, the oxygen flow rate (used in the pyrolysis step) and carrier and bypass gas flow rates. The possibility of using calibration with aqueous standard solutions was also investigated. Calibration using aqueous standard solutions was feasible for As, Sb and Te determination, and calibration using certified reference materials (CRMs) of coal was required for Se determination. For comparison of the results, coal samples were decomposed by microwave-assisted wet digestion to obtain reference values for As and Sb by ICP-MS and Se by collision/reaction cell technology inductively coupled plasma mass spectrometry (CRC-ICP-MS). In addition, samples were digested by microwave-induced combustion to obtain reference values for Te by ICP-MS. No statistical difference was observed between the results by SS-ETV-ICP-MS and those obtained by ICP-MS (As, Sb and Te) or CRC-ICP-MS (Se) after sample digestion. Additionally, CRMs of coal (NIST 1632b, NIST 1632c and NIST 1635) were analysed by SS-ETV-ICP-MS, and the results were in agreement with the certified values. The limit of quantification was 0.03, 0.01, 0.03 and 0.006 μg g−1 for As, Sb, Se and Te, respectively. These values were lower than those obtained by other methods and allowed the determination of analytes at trace and ultra-trace levels. The SS-ETV-ICP-MS method for coal presented other advantages, such as minimization of the sample preparation step, minimization of the use of large amounts of reagents and suitability of accurate determination of those analytes commonly susceptible to limitations using conventional methods.

Graphical abstract: Feasibility of As, Sb, Se and Te determination in coal by solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
30 апр 2018
Accepted
27 юни 2018
First published
16 юли 2018

J. Anal. At. Spectrom., 2018,33, 1384-1393

Feasibility of As, Sb, Se and Te determination in coal by solid sampling electrothermal vaporization inductively coupled plasma mass spectrometry

A. S. Henn, E. M. M. Flores, V. L. Dressler, M. F. Mesko, J. Feldmann and P. A. Mello, J. Anal. At. Spectrom., 2018, 33, 1384 DOI: 10.1039/C8JA00129D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements