Issue 4, 2019

High speed-low volume automated ICP-QMS method for determination of Mg/Ca in biogenic calcite

Abstract

The Mg/Ca molar ratio in foraminiferal calcite accumulated in marine sea sediments is a well-established proxy of ancient ocean temperatures. Magnesium is three orders of magnitude less abundant than Ca (0.5–10 mmol per mol), and the relationship between their ratio and sea surface temperature is exponential. Consequently, the reliability of the calculated temperature depends dramatically on the accuracy and precision of measurements, and the comparability of the results is heavily impacted by standardisation of the analytical methodology. Here, we extended the applicability of inductively coupled plasma-mass spectrometry for the determination of Mg/Ca in foraminifera, by implementing an automated on-line dual-dilution manifold combined with mixed instrumental acquisition modes (no gas-H2 reaction), and the use of on-line Sc addition as an internal standard. This allowed the independent acquisition of Mg and Ca at their optimised working concentrations under instrumental conditions that were free of significant spectral interferences. Matrix effects and instrumental drift are effectively mitigated, as supported by comparison with results from on-line isotope dilution analysis. Memory effects were minimized, and only 20 μg of calcitic material was required for analysis. Automation of the setup allowed dual dilution analysis of samples without any significant increase in preparation or analysis time. The system is easily upgradable to multiple on-line dilutions and multi-elemental ratios. The method was found to be accurate over the wide range of Mg/Ca values (from 0.8 to 5.7 mmol mol−1) present in the certified reference materials BAM-RS3, ECRM-752-1 and CMSI-1767, with repeatability in the range of 0.3–0.7% and an instrumental LOD of 0.6 nmol mol−1. Test application to five samples from the Integrated Ocean Drilling Program Site U1313 gave results consistent with literature values.

Graphical abstract: High speed-low volume automated ICP-QMS method for determination of Mg/Ca in biogenic calcite

Article information

Article type
Paper
Submitted
14 noy 2018
Accepted
19 fev 2019
First published
19 fev 2019

J. Anal. At. Spectrom., 2019,34, 764-773

High speed-low volume automated ICP-QMS method for determination of Mg/Ca in biogenic calcite

M. Roman, P. Ferretti, W. R. L. Cairns, A. Spolaor, C. Turetta and C. Barbante, J. Anal. At. Spectrom., 2019, 34, 764 DOI: 10.1039/C8JA00396C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements