Issue 3, 2018

Combination of micro X-ray fluorescence spectroscopy and time-of-flight secondary ion mass spectrometry imaging for the marker-free detection of CeO2 nanoparticles in tissue sections

Abstract

The description of nanoparticle distributions in tissue and associated effects is an important goal of nanotoxicology. Three-dimensional time-of-flight-secondary ion mass spectrometry (3D ToF-SIMS) is a promising label-free method to analyse tissue sections for nanoparticle distribution and to simultaneously detect organic and inorganic molecule species at high spatial resolution. As sample regions accessible to ToF-SIMS 3D imaging are limited to several hundred square micrometers, the proper selection of nanoparticle containing regions is mandatory. Micro X-ray fluorescence spectrometry (μ-XRF) provides a non-destructive, fast elemental analysis of large tissue sections with lateral resolution in the micrometer range. The latter technique was, therefore, used to screen samples as well as to validate elemental distribution images from ToF-SIMS 3D analysis. Specifically, cryo-sections from lungs inhomogeneously laden with CeO2 nanoparticles (10–200 nm) were subjected to μ-XRF and reflected light microscopy to pre-select lung tissue areas containing CeO2 NPs. The lateral resolution (670 nm) of ToF-SIMS imaging analyses in these areas exceeds the lateral resolution of μ-XRF imaging by a factor of 42 and reveals the lateral distribution of CeO2 NPs within the tissue structure. In addition, simultaneously acquired further secondary ions at a mass resolution of R = 4000 shed light on the sample composition. In summary, the investigation shows that μ-XRF is highly suitable to identify relevant tissue regions for subsequent high resolution ToF-SIMS 3D microanalysis of nanoparticle-laden tissue sections.

Graphical abstract: Combination of micro X-ray fluorescence spectroscopy and time-of-flight secondary ion mass spectrometry imaging for the marker-free detection of CeO2 nanoparticles in tissue sections

Supplementary files

Article information

Article type
Paper
Submitted
28 sen 2017
Accepted
30 yan 2018
First published
30 yan 2018

J. Anal. At. Spectrom., 2018,33, 491-501

Combination of micro X-ray fluorescence spectroscopy and time-of-flight secondary ion mass spectrometry imaging for the marker-free detection of CeO2 nanoparticles in tissue sections

L. Veith, D. Dietrich, A. Vennemann, D. Breitenstein, C. Engelhard, U. Karst, M. Sperling, M. Wiemann and B. Hagenhoff, J. Anal. At. Spectrom., 2018, 33, 491 DOI: 10.1039/C7JA00325K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements