Issue 5, 2018

Multispecies calibration: a novel application for inductively coupled plasma tandem mass spectrometry

Abstract

Inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) has significantly expanded the reach of analytical atomic spectrometry. In this work, we take advantage of the gas-phase chemistry available in ICP-MS/MS to propose a novel method of calibration. Rather than employing several standard solutions and a single mass-to-charge ratio, multispecies calibration (MSC) uses only one standard reference concentration and several chemical species of a monoisotopic element for calibration. In this work, multiple oxide and ammonia species generated in an ICP-MS/MS collision/reaction cell are used to determine As, Co and Mn in rice and liver samples. Only two calibration solutions are required per sample: S1 is a 1 : 1 mixture of sample and standard solution; S2 has the same 1 : 1 volume ratio of sample and blank. They are run separately, and the analytical calibration curve is built by plotting signal intensities from several ions containing the analyte. S1 and S2 signals are plotted on the x-axis and y-axis, respectively, and each point in the calibration plot corresponds to a different analyte species. The instrumental limits of detection calculated for As, Co and Mn were 0.07, 0.03, and 0.07 μg L−1, with RSDs estimated as 7.8, 3.1 and 1.8%, respectively (n = 10). Certified and MSC-determined values of As, Co and Mn in Tomato Leaves (NIST 1573a) and Bovine Liver (NIST 1577b) presented no statistically significant differences (Student's t-test, 95% confidence level, n = 3). The MSC results were comparable and sometimes better than values determined by the traditional external standard, internal standard and standard additions calibration methods.

Graphical abstract: Multispecies calibration: a novel application for inductively coupled plasma tandem mass spectrometry

Supplementary files

Article information

Article type
Paper
Submitted
04 fev 2018
Accepted
04 apr 2018
First published
04 apr 2018

J. Anal. At. Spectrom., 2018,33, 762-767

Author version available

Multispecies calibration: a novel application for inductively coupled plasma tandem mass spectrometry

C. B. Williams and George L. Donati, J. Anal. At. Spectrom., 2018, 33, 762 DOI: 10.1039/C8JA00034D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements