Issue 21, 2022

One-step and highly sensitive quantification of fusion genes with isothermal amplification initiated by a fusion-site anchored stem-loop primer

Abstract

As causative oncogenes and drug targets, fusion genes play critical roles in tumorigenesis, development, and treatment and thus are regarded as tumor-specific molecular biomarkers. Specific identification and sensitive quantification of fusion genes are of great significance in cancer diagnosis, classification, and prognosis as well as minimal residual disease (MRD) monitoring. Herein, we proposed a specific and sensitive method for the quantitative detection of fusion transcripts by designing stem-loop primers to directly track fusion junctions of fusion genes and subsequently initiate reverse transcript loop-mediated isothermal amplification (LAMP). Benefitting from the specific and direct mechanism of stem-loop primers and the high amplification efficiency of LAMP, the proposed method can sensitively measure fusion gene transcripts with a detection limit of 100 aM (1 zmol) and achieve a wide linear dynamic range spanning at least six orders of magnitude (100 aM–100 pM). Significantly, the whole fusion transcript assay can be accomplished in one step under isothermal conditions, greatly simplifying the operation and detection processes. Meanwhile, the one-step analysis method in one tube may effectively eliminate false-positive results from product cross-contamination during multiple experimental operations and cover-opening measurements. We have demonstrated that the proposed method is practical and accurate for the quantitation of fusion transcripts in biological samples. Owing to the outstanding features of high sensitivity, excellent specificity, and simple operation, the new strategy may provide a robust and attractive platform for the quantification of fusion genes.

Graphical abstract: One-step and highly sensitive quantification of fusion genes with isothermal amplification initiated by a fusion-site anchored stem-loop primer

Supplementary files

Article information

Article type
Paper
Submitted
09 محرم 1444
Accepted
19 صفر 1444
First published
19 صفر 1444

Analyst, 2022,147, 4786-4792

One-step and highly sensitive quantification of fusion genes with isothermal amplification initiated by a fusion-site anchored stem-loop primer

H. Wang, S. Wang, H. Wang, Y. Liang and Z. Li, Analyst, 2022, 147, 4786 DOI: 10.1039/D2AN01300B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements