Issue 5, 2020

Measurement of serum phosphate levels using a mobile sensor

Abstract

The measurement of serum phosphate concentration is crucial for patients with advanced chronic kidney disease (CKD) and those on maintenance dialysis, as abnormal phosphate levels may be associated with severe health risks. It is important to monitor serum phosphate levels on a regular basis in these patients; however, such measurements are generally limited to every 0.5–3 months, depending on the severity of CKD. This is due to the fact that serum phosphate measurements can only be performed at regular clinic visits, in addition to cost considerations. Here we present a portable and cost-effective point-of-care device capable of measuring serum phosphate levels using a single drop of blood (<60 μl). This is achieved by integrating a paper-based microfluidic platform with a custom-designed smartphone reader. This mobile sensor was tested on patients undergoing dialysis, where whole blood samples were acquired before starting the hemodialysis and during the three-hour treatment. This sampling during the hemodialysis, under patient consent, allowed us to test blood samples with a wide range of phosphate concentrations, and our results showed a strong correlation with the ground truth laboratory tests performed on the same patient samples (Pearson coefficient r = 0.95 and p < 0.001). Our 3D-printed smartphone attachment weighs about 400 g and costs less than 80 USD, whereas the material cost for the disposable test is <3.5 USD (under low volume manufacturing). This low-cost and easy-to-operate system can be used to measure serum phosphate levels at the point-of-care in about 45 min and can potentially be used on a daily basis by patients at home.

Graphical abstract: Measurement of serum phosphate levels using a mobile sensor

Supplementary files

Article information

Article type
Paper
Submitted
08 ربيع الأول 1441
Accepted
14 جمادى الأولى 1441
First published
15 جمادى الأولى 1441

Analyst, 2020,145, 1841-1848

Author version available

Measurement of serum phosphate levels using a mobile sensor

A. Ray, S. Esparza, D. Wu, M. R. Hanudel, H. Joung, B. Gales, D. Tseng, I. B. Salusky and A. Ozcan, Analyst, 2020, 145, 1841 DOI: 10.1039/C9AN02215E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements