Issue 8, 2018

A systematic look at the carbon monosulfide molecule and chemical modifiers for the determination of sulfur by HR-CS GF MAS

Abstract

This work describes an adequate method for the stabilization of three forms of sulfur (ionic, saturated, and unsaturated), with different chemical modifiers (Zr, Pd and Ca) during sulfur measurement as carbon monosulfide (CS) by high-resolution continuum source graphite furnace molecular absorption spectrometry. Sulfur contained in different liquid samples, such as milk, orange juice, swamp water, urine and digested samples (whole egg powder and rice flour), has been stabilized during drying and pyrolysis steps. Monitoring CS at 258.0560 nm provided the same sensitivity and thermal stability for all sulfur species tested by using 10 μL of Ca (1 g L−1) and 2 μL of Pd (10 g L−1), and covering the platform with Zr (400 μg). The optimum pyrolysis and vaporization temperatures were found to be 600 °C and 2300 °C, respectively. Aqueous standard solutions of ammonium sulfate, L-cysteine, and thiourea were used for calibration, in the linear range of 0.02 μg to 2 μg S (2 mg L−1 to 200 mg L−1 S, 10 μL injection) with a linear correlation R greater than 0.996. The LOD and LOQ were 6 ng and 20 ng S (0.6 mg L−1 and 2 mg L−1 S), respectively, with a precision of 0.5% to 7% RSD. In the accuracy evaluation, concordances of 93% and 100% for NIST 8415 and NIST 1568a, respectively, have been found in the comparison of the certified value and that found by the proposed method. The developed method was employed for direct S determination in different samples and also those prepared via the microwave assisted digestion procedure. No significant differences (p > 0.05) were found.

Graphical abstract: A systematic look at the carbon monosulfide molecule and chemical modifiers for the determination of sulfur by HR-CS GF MAS

Article information

Article type
Paper
Submitted
23 شعبان 1439
Accepted
18 شوال 1439
First published
18 شوال 1439

J. Anal. At. Spectrom., 2018,33, 1394-1401

A systematic look at the carbon monosulfide molecule and chemical modifiers for the determination of sulfur by HR-CS GF MAS

É. R. Pereira, B. Welz and A. A. Vieira, J. Anal. At. Spectrom., 2018, 33, 1394 DOI: 10.1039/C8JA00146D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements