Issue 5, 2022

SE-ECL on CMOS: a miniaturized electrochemiluminescence biosensor

Abstract

Biosensors exhibit high potential for the detection of analytes of interest at the point-of-need. Over the past two decades, the combination of novel biosensing systems – such as electrochemiluminescence (ECL) biosensors – and advances in microfluidic techniques has allowed the development of lab-on-a-chip devices with enhanced overall performance and simplified sample handling. However, recording data with conventional platforms requires advanced and complicated instruments, such as sensitive photodetectors coupled to microscopes, to capture the photons from the chemiluminescent reaction. In this work, we integrated microfluidic and luminol/hydrogen peroxide ECL systems on a complementary metal-oxide-semiconductor (CMOS) chip for sample handling and data collection on the same platform. This was achieved by the adaptation of a single electrode as an electrochemical transducer and a CMOS chip as a built-in detector. We demonstrated the application of this platform for the detection of uric acid (UA), a biomarker of gout disease. A linear detection range was observed from 25 to 300 μM, with a detection limit (LOD) as low as 26.09 μM. The device showed high reusability and reproducibility within the linear detection range while maintaining high selectivity for UA detection. The analytical performance has also been evaluated in simulated saliva and urine samples, demonstrating the potential utility in medical diagnosis at the point-of-need. Compared to other ECL imaging platforms, this device showed an eightfold increase in photon collection efficiency. Overall, this approach has promising potential as an inexpensive, portable, and efficient ECL platform for measuring analytes at the point-of-need.

Graphical abstract: SE-ECL on CMOS: a miniaturized electrochemiluminescence biosensor

Article information

Article type
Paper
Submitted
01 ربيع الأول 1443
Accepted
26 جمادى الثانية 1443
First published
06 رجب 1443

Lab Chip, 2022,22, 994-1005

SE-ECL on CMOS: a miniaturized electrochemiluminescence biosensor

R. Abbasi, J. Liu, S. Suarasan and S. Wachsmann-Hogiu, Lab Chip, 2022, 22, 994 DOI: 10.1039/D1LC00905B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements