Issue 20, 2022

A rapid and simple electrochemical detection of the free drug concentration in human serum using boron-doped diamond electrodes

Abstract

Monitoring drug concentration in blood and reflecting this in the dosage are crucial for safe and effective drug treatment. Most drug assays are based on total concentrations of bound and unbound proteins in the serum, although only the unbound concentration causes beneficial and adverse events. Monitoring the unbound concentration alone is expected to provide a means for further optimisation of drug treatment. However, unbound concentration monitoring has not been routinely used for drug treatment due to the long analysis time and the high cost of conventional methods. Here, we have developed a rapid electrochemical method to determine the unbound concentration in ultrafiltered human serum using boron-doped diamond (BDD) electrodes. When the anticancer drug doxorubicin was used as the test drug, the catalytic doxorubicin-mediated reduction of dissolved oxygen provided a sensitive electrochemical signal, with a detection limit of 0.14 nM. In contrast, the sensitivity of glassy carbon (GC) was inferior under the same conditions due to interference from the dissolved oxygen reduction current. The signal background ratio (S/B) of BDD and GC was 11.5 (10 nM doxorubicin) and 1.1 (50 nM), respectively. The results show that a fast measurement time within ten seconds is possible in the clinical concentration range. Additionally, in the ultrafiltered human serum, the obtained values of unbound doxorubicin concentration showed good agreement with those quantified by conventional liquid chromatography-mass spectrometry. This approach has the potential for application in clinical settings where rapid and simple analysis methods would be beneficial.

Graphical abstract: A rapid and simple electrochemical detection of the free drug concentration in human serum using boron-doped diamond electrodes

Supplementary files

Article information

Article type
Paper
Submitted
28 ذو القعدة 1443
Accepted
15 صفر 1444
First published
17 صفر 1444

Analyst, 2022,147, 4442-4449

A rapid and simple electrochemical detection of the free drug concentration in human serum using boron-doped diamond electrodes

H. Moriyama, G. Ogata, H. Nashimoto, S. Sawamura, Y. Furukawa, H. Hibino, H. Kusuhara and Y. Einaga, Analyst, 2022, 147, 4442 DOI: 10.1039/D2AN01037B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements