Issue 31, 2021

Open port sampling interface mass spectrometry of wipe-based explosives, oxidizers, and narcotics for trace contraband detection

Abstract

Rapid screening for chemical traces of explosives and narcotics is widely used to support homeland security and law enforcement. These target compounds span a range of physicochemical properties from organic to inorganic, with preferential ionization pathways in both negative and positive mode operation. Nonvolatile inorganic oxidizers present in homemade fuel-oxidizer mixtures, pyrotechnics, and propellants create a unique challenge to traditional thermal desorption-based technologies. Developments in solid–liquid extraction techniques, specifically, open port sampling interface mass spectrometry (OPSI-MS) provide compelling capabilities to address these hurdles. In this proof of concept study, we investigated the trace detection of wipe-based (i.e., common swipe sampling collection method) explosives, oxidizers, and narcotics using an OPSI source and compact single quadrupole mass analyzer. The liquid dissolution and extraction capabilities of OPSI enabled detection of both traditional military-grade explosives and homemade explosive oxidizers. OPSI-MS sensitivities to a series of seven target compounds from polytetrafluoroethylene (PTFE) coated fiberglass sampling wipes were on the order of several nanograms to sub-nanogram levels. Comparisons with direct solution-based sample analysis enabled quantification of wipe-based sample extraction effects. The system demonstrated quick temporal responses, polarity switching capabilities, and rapid signal decay with minimal carryover, all critical to high throughput screening applications. Coupling traditional swipe sampling with OPSI-MS offers a promising tool for contraband screening applications.

Graphical abstract: Open port sampling interface mass spectrometry of wipe-based explosives, oxidizers, and narcotics for trace contraband detection

Supplementary files

Article information

Article type
Communication
Submitted
07 ذو القعدة 1442
Accepted
08 ذو الحجة 1442
First published
09 ذو الحجة 1442

Anal. Methods, 2021,13, 3453-3460

Open port sampling interface mass spectrometry of wipe-based explosives, oxidizers, and narcotics for trace contraband detection

T. P. Forbes, J. Lawrence, C. Hao and G. Gillen, Anal. Methods, 2021, 13, 3453 DOI: 10.1039/D1AY01038G

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements