Issue 19, 2017

Sensitive and selective detection of the p53 gene based on a triple-helix magnetic probe coupled to a fluorescent liposome hybridization assembly via rolling circle amplification

Abstract

Developing a sensitive and selective sensing platform for the p53 gene and its mutation analysis is essential and may aid in early cancer screening and assessment of prognosis. Here, we developed a highly sensitive and selective p53 gene assay based on the coupling of a triple-helix magnetic probe (THMP) to a fluorescent liposome hybridization assembly, a process initiated by rolling circle amplification (RCA). In the presence of p53, the THMP unfolds and activates an enzymatic cleavage reaction, thus releasing the RCA primer and initiating the RCA product-assisted fluorescent liposome hybridization assembly. The resultant double-stranded DNA structures bind the intercalating SG dye from the fluorescent liposomes, thus dramatically enhancing the fluorescence signal. In the absence of p53, the THMP remains intact and blocks the trigger release and fluorescent liposome assembly, thus resulting in a low background signal. The THMPs were designed with integrated target recognition by Watson–Crick base-pairing, site-specific cleavage by an endonuclease and background signal elimination by magnetic isolation, thus avoiding the need to design multiple probes. Moreover, the use of fluorescent liposome assembly and magnetic isolation helps in avoiding sample matrix interference and nonspecific staining. Through cooperative amplification coupling with enzyme cleavage recycling, the RCA-assisted fluorescent liposome assembly and magnetic isolation improved the sensitivity, with a detection limit of 0.07 fM. The excellent capacity of the THMP to specifically detect the involved targets and the precise site-specific endonuclease cleavage ensured remarkable selectivity for p53 against single-base mismatches. This proposed approach worked well in biological samples, thus demonstrating great potential for biomedical and clinical diagnosis applications.

Graphical abstract: Sensitive and selective detection of the p53 gene based on a triple-helix magnetic probe coupled to a fluorescent liposome hybridization assembly via rolling circle amplification

Supplementary files

Article information

Article type
Paper
Submitted
07 ذو القعدة 1438
Accepted
30 ذو القعدة 1438
First published
01 ذو الحجة 1438

Analyst, 2017,142, 3598-3604

Sensitive and selective detection of the p53 gene based on a triple-helix magnetic probe coupled to a fluorescent liposome hybridization assembly via rolling circle amplification

X. Li, J. Song, Q. Xue, H. Zhao, M. Liu, B. Chen, Y. Liu, W. Jiang and C. Li, Analyst, 2017, 142, 3598 DOI: 10.1039/C7AN01255A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements