Issue 12, 2016

More from less: high-throughput dual polarity lipid imaging of biological tissues

Abstract

The high ion signals produced by many lipids in mass spectrometry imaging (MSI) make them an ideal molecular class to study compositional changes throughout tissue sections and their relationship with disease. However, the large extent of structural diversity observed in the lipidome means optimal ion signal for different lipid classes is often obtained in opposite polarities. In this work we demonstrate how new high speed MALDI-MSI technologies combined with precise laser position control enables the acquisition of positive and negative ion mode lipid data from the same tissue section much faster than is possible with other MSI instruments. Critically, using this approach we explicitly demonstrate how such dual polarity acquisitions provide more information regarding molecular composition and spatial distributions throughout biological tissues. For example, in applying this approach to the zebra finch songbird brain we reveal the high abundance of DHA containing phospholipids (PC in positive mode and PE, PS in negative ion mode) in the nuclei that control song learning behaviour. To make the most of dual polarity data from single tissues we have also developed a pLSA-based multivariate analysis technique that includes both positive and negative ion data in the classification approach. In doing so the correlation amongst different lipid classes that ionise best in opposite polarities and contribute to certain spatial patterns within the tissue can be directly revealed. To demonstrate we apply this approach to studying the lipidomic changes throughout the tumor microenvironment within xenografts from a lung cancer model.

Graphical abstract: More from less: high-throughput dual polarity lipid imaging of biological tissues

Supplementary files

Article information

Article type
Paper
Submitted
13 ربيع الثاني 1437
Accepted
15 جمادى الثانية 1437
First published
15 جمادى الثانية 1437

Analyst, 2016,141, 3832-3841

More from less: high-throughput dual polarity lipid imaging of biological tissues

S. R. Ellis, J. Cappell, N. O. Potočnik, B. Balluff, J. Hamaide, A. Van der Linden and R. M. A. Heeren, Analyst, 2016, 141, 3832 DOI: 10.1039/C6AN00169F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.