Issue 13, 2014

Determination of P, S and Si in biodiesel, diesel and lubricating oil using ICP-MS/MS

Abstract

The feasibility of inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) to overcome polyatomic interferents in severely affected isotope determination is demonstrated here. This instrument arrangement presents an octopole reaction/collision system (ORS) in between two quadrupole mass analyzers. The first quadrupole operates as a mass filter which allows just the target mass-to-charge ratio (m/z) to enter the ORS and rejects all other species with m/z different from the target analyte's m/z. Once in the ORS, analytes react with the reaction gas introduced into the ORS, and the second quadrupole selects the product of the reaction's m/z (mass shift operation mode). We describe here a procedure for accurate determination of P, S and Si in biodiesel, diesel and lubricating oil by ICP-MS/MS. Fuel standard reference materials (SRMs) were microwave-assisted acid-digested using nitric acid and hydrogen peroxide. The oxygen gas flow rate in the ORS was optimized considering the limit of detection (LOD) values and accuracies reached for P, S and Si determinations in the lubricating oil SRM and the best oxygen gas flow rate was 0.75 mL min−1. Adopting optimized conditions, limits of detection were 1.2, 0.49, 0.31, 0.33 and 0.78 μg L−1 for 28Si16O+, 29Si16O+, 31P16O+, 32S16O+ and 34S16O+, respectively. Adequate precision, accuracy and sensitivity were obtained when using the mass shift mode and recoveries for biodiesel, diesel and lubricating oil digests ranged from 95.0 to 113%. No significant differences were observed between the certified values and the ones obtained using ICP-MS/MS at a 95% confidence level.

Graphical abstract: Determination of P, S and Si in biodiesel, diesel and lubricating oil using ICP-MS/MS

Article information

Article type
Paper
Submitted
02 ربيع الثاني 1435
Accepted
17 جمادى الثانية 1435
First published
17 جمادى الثانية 1435

Anal. Methods, 2014,6, 4516-4520

Determination of P, S and Si in biodiesel, diesel and lubricating oil using ICP-MS/MS

R. S. Amais, C. D. B. Amaral, L. L. Fialho, D. Schiavo and J. A. Nóbrega, Anal. Methods, 2014, 6, 4516 DOI: 10.1039/C4AY00279B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements