Issue 17, 2021

A substantial increase of analytical throughput in capillary electrophoresis throughput by separation-interrupted sequential injections

Abstract

How to further improve the throughput of capillary electrophoresis (CE) is a fascinating question. Herein an idea to substantially increase the throughput of CE has been proposed together with theory and experimental demonstration. The key is to introduce samples for CE, one after another, by a short suspension of voltage application, which was hence termed separation-interrupted sequential injections (Sisi). The idea was demonstrated to be feasible on a laboratory-built CE instrument coupled with tandem C4D (contactless capacitively-coupled conductivity) detectors. At least 50 injections of a testing sample (mixture of NH4+, K+, Ca2+, Na+ and Mg2+) were successfully separated in only a single run. The separation took 145 min in total, equivalent to 2.9 min per analysis which is only 21% of that of normal CE. Quantification of the separated ions was performed, with a limit of detection of 1.1–2.6 μM, a limit of quantification of 3.2–8.9 μM, and a linear range up to 1000 μM (R2 > 0.99). The recovery was between 88% and 112% measured by spiking standards into samples at low, middle and high levels. The real applicability of Sisi-CE was evaluated by direct injection and analysis of 45 mineral water samples also in a single run. Its clinical application potential was demonstrated by high throughput assay of the calcium and zinc gluconate oral solution formula, and the blood potassium of hyperkalemia and hypokalemia from patients with renal failure disease. This method can be extended to other applications such as omics studies through the use of more suitable detectors. The theory proposed may also be applicable to other high throughput methods.

Graphical abstract: A substantial increase of analytical throughput in capillary electrophoresis throughput by separation-interrupted sequential injections

Supplementary files

Article information

Article type
Paper
Submitted
24 جمادى الثانية 1442
Accepted
06 شعبان 1442
First published
06 شعبان 1442

Anal. Methods, 2021,13, 1995-2004

A substantial increase of analytical throughput in capillary electrophoresis throughput by separation-interrupted sequential injections

H. Li, C. Guo, Q. Zhang, L. Bao, Q. Zheng, Z. Guo and Y. Chen, Anal. Methods, 2021, 13, 1995 DOI: 10.1039/D1AY00223F

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements