Ananthu
Shanmughan
,
Mini Ajith
Nithasha
,
Binduja
Mohan
,
Deivasigamani
Umadevi
* and
Sankarasekaran
Shanmugaraju
*
Department of Chemistry, Indian Institute of Technology Palakkad, Palakkad-678557, Kerala, India. E-mail: shanmugam@iitpkd.ac.in; umadevi@iitpkd.ac.in
First published on 4th September 2023
A new Tröger's base containing fluorenone organic polymer (TB-FL-COP) was synthesized and used as a fluorescence sensor for discriminative sensing of antibiotics in water. TB-FL-COP showed the highest fluorescence quenching, reversible sensing responses, and excellent sensitivity of 56 ppb level for sulfamethazine antibiotics. The Stern–Volmer quenching constant (KSV) was calculated to be 1.2 × 106 M−1. The fluorescence sensing ability was also reflected by sharp visual color changes and further demonstrated in real water samples.
Several instrumental techniques including Raman spectroscopy, capillary electrophoresis, and ion mobility spectrometry are currently used for the detection of antibiotics.17,18 However, massive instrumentation setup, high-maintenance cost and tedious instrument calibration, and required trained technician impair their practical utilization.19 On the other hand, fluorescence-based sensing has become an attractive method for trace analysis of antibiotics because of its high sensitivity, fast response time, and easy operational procedure.20,21 Given this, in recent years, a wide variety of fluorescence sensors such as luminescent metal–organic frameworks, fluorescent organic polymers, and small-molecule fluorescent sensors have been developed and employed for the detection of different kinds of antibiotics.1,22,23 Among the various fluorescence sensors known, luminescent covalent organic polymers (COPs) have become a popular sensor system for antibiotics detection because of their facile synthesis, modular functional properties, amplified sensing responses, superior sensitivity to analytes, and high thermal and chemical stability.24,25
Considering these advantages, herein, we report a new Troger's base containing fluorenone luminescent organic polymer (TB-FL-COP) for fluorescence ‘turn-off’ sensing of antibiotics, in particular for selective, sensitive, quick, and reversible sensing of SMZ antibiotics in water. We introduced Tröger's base moiety because its unique V-shaped structure provides a large hydrophobic cavity that can be exploited for effective host–guest complexation with guest molecules.26 The C2 symmetry of Tröger's base bicyclic unit could easily be introduced within the polymer skeleton by a simple acid-catalyzed cyclization reaction of aromatic primary amines with paraformaldehyde or dimethoxymathane.27–30 Tröger's base structure contains two stereogenic ‘N’ atoms which can act as potential receptor sites (Lewis base) for the recognition and sensing of various analytes.31–33 Likewise, the π-electron-rich fluorenone moiety was introduced on the backbone of the polymer chain because of its rich-photophysical properties and diverse optoelectronic applications.34,35 Also, the large aromatic surface of fluorenone endows the polymers to be highly emissive and can form an efficient donor–acceptor type complex with π-electron-deficient analytes through supramolecular interactions.36
The Shimadzu Scientific Instruments (IR Tracer 100) equipped with an ATR sampler were used to obtain the FT-IR spectrum of the polymer. The solid-state CP-MAS 13C-NMR spectrum of TB-FL-COP was acquired at 201.1 MHz using a 3.2 mm double-resonance MAS probe. Thermogravimetric analysis (TGA) of TB-FL-COP was performed on the PerkinElmer STA 8000 analyzer equipped with an ultra-microbalance with a sensitivity of 0.1 mg. The temperature range was from 25 °C to 800 °C with a scan rate of 10 °C min−1 under the N2 purge. The powder X-ray diffraction analysis was performed on Rigaku (XRD Smart Lab) diffractometer operating at 9 kW. The morphology of TB-FL-COP was imaged using field-emission scanning electron microscopy (FE-SEM) on Carl Zeiss (Gemini SEM 300) microscopy. The sample was prepared by drop-casting the suspension of the as-synthesized polymer on silica wafers, then coated with Au and dried under vacuum before the imaging.
The surface area of the polymer was determined using an N2 physisorption isotherm. Before the adsorption measurement, the sample was evacuated under a vacuum to remove already trapped solvents. The UV-visible absorption spectra were recorded in a 1 cm quartz cuvette on a Thermo Fisher scientific spectrometer, and baseline correction was applied for all spectra. The emission spectra for all the experiments were recorded on a PerkinElmer FL-8500 fluorescence spectrophotometer equipped with a xenon arc (150 W) light source. The temperature was kept constant throughout the measurements at 298 K. All spectroscopic measurements were recorded in a quartz cuvette with a scan rate of 1200 nm min−1. The obtained results were plotted using Origin Pro 8.5 software.
The percentage of fluorescence quenching efficiency was calculated from the following equation:
Quenching efficiency (%) = (I0 − I)/I0 × 100 |
The relative changes (I0/I) in emission intensity upon increasing the concentration [Q] of antibiotics was demonstrated by the following Stern–Volmer equation:
I0/I = KSV[Q] + 1 |
The Stern–Volmer quenching constant (KSV) was determined from the slope of the linear curve.
The limit of detection was calculated using the following equation:
Limit of detection (LoD) = 3σ/K |
The chemical structure of TB-FL-COP was characterized by FT-IR and solid-state cross-polarization magic-angle spinning (CP/MAS) 13C NMR. In the FT-IR spectrum of TB-FL-COP, a new stretching band appeared at 1273 cm−1 corresponding to the C–N stretching vibrations of Tröger's base unit. Upon polymer formation, the intense broadband observed at 3348 cm−1 corresponding to the N–H stretching frequency of NH2 groups of monomers nearly disappeared (Fig. 1A). In the CP-MAS 13C-NMR spectrum, two peaks appeared at δ = 34.00 and 32.98 ppm corresponding to the C atoms of Tröger's base unit. These results strongly support the presence of Tröger's base moiety in the isolated TB-FL-COP polymer.
Fig. 1 (A) The FT-IR spectrum of polymer TB-FL-COP and monomer. The FESEM images of TB-FL-COP were imaged at (B) 100 and (C) 200 nm resolutions. |
Thermogravimetric analysis (TGA) of TB-FL-COP under an N2 atmosphere revealed that the as-synthesized polymer was stable up to 400 °C indicating its high thermal stability (Fig. S1, ESI†). The powder X-ray diffraction pattern of TB-FL-COP displayed a broad band with no obvious peaks which confirms the amorphous nature of TB-FL-COP (Fig. S2, ESI†). The amorphous form of TB-FL-COP facilitates its solution processability for sensing applications. The field-emission scanning electron microscopy (FESEM) imaging of TB-FL-COP showed that the polymer particles were aggregated to form a morphology of non-homogeneous sphere-shaped units on the solid surface (see Fig. 1B and C). The surface property of TB-FL-COP was evaluated using physisorption studies. Adsorption isotherm of N2 intake was recorded at 77 K, which revealed that the TB-FL-COP has an average pore radius of 2.79 Å, and a pore volume of 0.571 cc g−1 (Fig. S3, ESI†). The Brunauer–Emmett–Teller (BET) surface area of the polymer was calculated to be 41 m2 g−1 and hence, TB-FL-COP can be a potential molecular adsorbent for guest encapsulation.
As shown in Fig. 2A, TB-FL-COP exhibited differential fluorescence quenching responses for different antibiotics. Among various antibiotics, SMZ antibiotics displayed the highest fluorescence quenching while other antibiotics such as FZD, CRP, NFT, DMZ, and SDZ showed moderate to poor fluorescence quenching responses. The high selectivity of TB-FL-COP for SMZ antibiotic was also reflected by a sharp visual color change (see Fig. 2A inset). The bright blue emission of TB-FL-COP become almost colorless upon the addition of SMZ while other antibiotics did not show any observable color changes. To further confirm the high selectivity of TB-FL-COP towards SMZ, competitive fluorescence titration studies were performed using SMZ in the presence of other competing antibiotics. As shown in Fig. 2B, the initial emission intensity of TB-FL-COP (red bar) was moderately quenched (green bar) upon the addition of various other antibiotics, however, the subsequent addition of SMZ antibiotic to the previous solution caused a strong fluorescence quenching (blue bar). These results demonstrate the preferential binding affinity and discriminative sensing propensity of TB-FL-COP towards SMZ even in the presence of other competing antibiotics.
To further probe the fluorescence sensing propensity of TB-FL-COP towards SMZ, a fluorescence titration study was carried out. The initial strong fluorescence emission at λ = 526 nm observed for TB-FL-COP was decreased in intensity upon the gradual increase in the concentration of SMZ (see Fig. 3A). From the fluorescence titration profile, a non-linear Stern–Volmer plot was obtained which indicates a complex fluorescence quenching mechanism involves in the overall quenching processes. The Stern–Volmer quenching constant KSV = 1.2 × 106 M−1 was determined from the slope of a linear plot obtained at a low concentration of SMZ. The relatively high KSV value indicates a strong binding affinity of TB-FL-COP for SMZ antibiotics. The calculated KSV value is comparable to other reported polymer-based fluorescence sensors for antibiotics.38,39 Similar fluorescence titration studies in a PBS buffer medium using TB-FL-COP displayed a strong fluorescence quenching in the presence of SMZ and thus TB-FL-COP is a practically more useful sensor for SMZ detection (Fig. S4, ESI†). Likewise, under identical spectroscopic conditions, fluorescence titration was carried out using other antibiotics. It was observed that the extent of fluorescence quenching was different for different antibiotics and from the titration profile, the fluorescence quenching constant was calculated to be in the order of KSV = 103–104 M−1, these values are lower than the quenching constant calculated for SMZ (see Table S1 in ESI†).
Furthermore, the UV-visible absorption titration study and time-dependent fluorescence lifetime measurement were carried out to probe the plausible mechanism for the observed fluorescence quenching. As shown in Fig. S5 (in ESI†), the initial absorption intensity of TB-FL-COP increases with increasing the concentration of SMZ (0.0 to 90.9 × 10−6 M), which indicates that TB-FL-COP binds with SMZ in the ground-state. This was further supported by the time-dependent lifetime measurement. The lifetime of TB-FL-COP (τ = 0.1 ns) remained almost unchanged after the addition of SMZ antibiotics (90.9 × 10−6 M), except for a slight increase to 0.15 ns (Fig. S6 in ESI†). All these results including sharp visual color changes of TB-FL-COP after the addition of SMZ (Fig. 2A inset) and obtained linear Stern–Volmer plot at low concentration (Fig. 3B inset) indicate that TB-FL-COP forms a donor–acceptor type of charge-transfer (CT) complex with SMZ in the ground state at low concentration, which resulted in strong fluorescence quenching via the static quenching mechanism. However, a non-linear plot at a high concentration of SMZ indicates that fluorescence quenching is due to both static and dynamic quenching mechanisms (Fig. 3B).
The highest fluorescence quenching of TB-FL-COP for SMZ antibiotic was further validated by computational modeling using Density Functional Theory (DFT) calculations. All computational analyses were performed at the B3LYP/6-311++G(d,p) level of theory using the Gaussian 16 program.40 The frontier molecular orbitals (HOMO and LUMO) energies for various antibiotics were calculated and compared with the HOMO and LUMO energy values of the TB-FL-COP model system. The LUMO energy value for antibiotics was found to be lower in energy than TB-FL-COP and thus, they can readily form a donor–acceptor type of charge transfer complex sensor and subsequently result in fluorescence quenching (see Table S2 in ESI†). The observed difference in the extent of fluorescence for different antibiotics is presumably due to the difference in the extent of energy transfer between the sensor and analyte. The highest fluorescence quenching for SMZ was ascribed to its enhanced energy transfer from the sensor since the LUMO of SMZ is placed at lower energy and much closure to the LUMO of TB-FL-COP compared to the LUMO energy of all other antibiotics (Fig. 4).
To determine the sensitivity of TB-FL-COP for antibiotics detection, the fluorescence titration studies were performed by taking micromolar (μM) concentrations of SMZ. It was found that TB-FL-COP can detect the presence of SMZ even at the nanomolar (nm) level of concentrations and the LoD value was determined to be 56 ppb, this value of sensitivity is much lower than several other reported fluorescence and other types of sensors reported for antibiotic detection (see Table S3†).41,42 A time-dependent fluorescence titration study was also performed to know the fluorescence quenching response time of TB-FL-COP for SMZ. The emission intensity of TB-FL-COP was monitored at various time intervals and quenching efficiency was plotted against contact time. Upon the addition of a 90.9 μM concentration of SMZ, a quenching efficiency of 98% was reached within 30 seconds after the addition of SMZ (Fig. S5A†). The instantaneous increase in fluorescence quenching indicates that TB-FL-COP can be used as a fast fluorescence sensor for antibiotics detection. Furthermore, the effect of the pH of the sensing medium on the sensing performances of TB-FL-COP towards SMZ was studied. As shown in Fig. S7 in ESI,†TB-FL-COP was found to be highly emissive in basic pH > 8 and the highest fluorescence emission was observed at pH = 10. While in the acidic pH < 5, TB-FL-COP was less emissive. Notably, the addition of SMZ antibiotics quenches the fluorescence emission of TB-FL-COP almost in all pH of the sensing medium. These results indicate that the effect of pH on the fluorescence sensing performance of TB-FL-COP is inconsequential.
To check the reversibility, the fluorescent intensity of TB-FL-COP in water was measured before and after adding a 45.5 μM concentration of SMZ solution. After the measurement, the TB-FL-COP solution containing SMZ was washed several times with ethyl acetate to remove SMZ and subsequent fluorescence measurements indicate that TB-FL-COP regain the initial emission intensity. This procedure was repeated for several cycles and almost 91% of the initial emission intensity recovered even after six cycles. Thus, the recyclability of TB-FL-COP enriches its practical application of sensing antibiotics (see Fig. 5). To explore the sensor's usefulness in real-world applications, a fluorescence titration study with water samples was carried out. Water from a pond near Ahalia Hospital in Palakkad was used to make SMZ and TB-FL-COP stock solutions, which were then titrated to achieve high fluorescence quenching. Interestingly, TB-FL-COP exhibited a strong fluorescence quenching in the presence of SMZ in real-water samples (Fig. S8, ESI†). Despite the presence of many water contaminants and impurities in the pond water, the observed strong fluorescence quenching validates the potential application of TB-FL-COP for SMZ detection even in the real-water medium.
Footnote |
† Electronic supplementary information (ESI) available: Solid-state CP-MAS 13C-NMR, thermogravimetric analysis, powder X-ray diffraction pattern, gas adsorption isotherm and fluorescence studies. See DOI: https://doi.org/10.1039/d3py00857f |
This journal is © The Royal Society of Chemistry 2023 |