Haibin
Xiao‡
,
Ping
Li‡
,
Wei
Zhang
and
Bo
Tang
*
College of Chemistry, Chemical Engineering and Materials Science, Collaborative Innovation Center of Functionalized Probes for Chemical Imaging in Universities of Shandong, Key Laboratory of Molecular and Nano Probes, Ministry of Education, Shandong Provincial Key Laboratory of Clean Production of Fine Chemicals, Shandong Normal University, Jinan 250014, P. R. China. E-mail: tangb@sdnu.edu.cn
First published on 23rd November 2015
Mitochondrial polarity is a crucial characteristic of these indispensable organelles, and tremendously impacts cellular events. Herein, we describe a new mitochondria-targeting fluorescent probe MCY-BF2 that is singularly sensitive and specifically responsive to mitochondrial polarity. The pull–push system in the conjugated structure of MCY-BF2 is responsible for the polarity-ultrasensitivity due to the excited state intramolecular charge transfer (ICT). By combining with cardiolipin, MCY-BF2 preferentially accumulates in mitochondria. Because the fluorescence emission wavelengths exhibit an obvious red-shift with increasing media polarity, the fluorescence intensity ratio at two different wavelengths versus the solvent dielectric constant can quantify the mitochondrial polarity. Experimental results demonstrate that the fluorescent intensity of MCY-BF2 in a non-polar solvent, dioxane, is 120 times higher than that in a polar solvent, dimethyl sulfoxide. As the first near-infrared (NIR) and most sensitive fluorescent imaging probe for polarity, MCY-BF2 can locate exclusively in mitochondria in various cells and discriminate polarity differences between normal and cancer cells. Also, the intrinsic polarity variance at different developmental stages in Caenorhabditis elegans (C. elegans) was reported here for the first time. Interestingly, the embryonic development stage has a more non-polar environment with a dielectric constant of 7.20, and in contrast the polarity at the young adult stage changes to 10.07. In addition, in vivo imaging results suggest that the tumor tissues of mice have an obviously lower polarity than that in normal tissues. Altogether, the merits of the NIR property, high sensitivity and moderate Stokes shift all greatly promote the accuracy of imaging. This probe will be a promising tool for studying biological processes and the pathological mechanism of polarity-related diseases.
Fluorescence imaging is a promising and powerful method for monitoring various bioactive molecules in living systems. Consequently, an increasing number of fluorescent probes suitable for real-time imaging have been developed in recent years, which has facilitated progress in cell biology and therapeutics imaging.16–18 Nevertheless, ideal fluorescent probes for monitoring mitochondrial polarity should possess the following unique merits: (1) high sensitivity and selectivity to polarity without being affected by other complicated mitochondrial microenvironments; (2) maximum fluorescence excitation and emission wavelengths in the NIR region to reduce interference from background fluorescence; (3) accurate mitochondria-targeting ability, and (4) a ratiometric fluorescence response for a quantitative assay. Although some polarity-sensitive fluorescent probes for solvents, the surface of a protein, and even live cells have been exploited in recent years,14,19–27 a versatile polarity probe satisfying all the aforementioned requirements has not been reported.
To solve these problems mentioned above, we herein fabricated a series of new compounds, 1–4 (Scheme 1), composed of a merocyanine moiety with various lipophilic side chains and a difluoroboronate moiety used to sensitively monitor the polarity. In this framework, the long conjugated system and asymmetric structure account for the NIR excitation/emission spectra and large Stokes shift, respectively. Meanwhile, the tertiary amine and difluoroboronate moieties serve as electron donating and accepting groups, respectively, resulting in the formation of an intense push–pull construction. When the environment polarity increases, the excited state energy can be dissipated due to the dipole–dipole interaction between the probe molecules and solvent due to the excited state ICT,28,29 which is responsible for the polarity sensitivity. Therefore, the designed compounds should exhibit weak fluorescence and a longer emission wavelength in polar media, and in contrast, a strong fluorescence and shorter emission wavelength in non-polar media.23 As a result of red-shifting of the emission wavelength with increasing polarity, a plot of the fluorescence intensity ratios at two different wavelengths versus the dielectric constant may be achieved, which can then be utilized to estimate the polarity of certain media and live cells. Considering the characteristics of mitochondria which distinguish them from other subcellular compartments, cardiolipin (CL, a diphosphatidylglycerol lipid) is exclusively found in the inner membrane of mitochondria.30 Previous studies revealed that some molecules bearing lipophilic cations can effectively bind mitochondrial CL through electrostatic attraction and lipophilic interactions.31 Based on this idea, we introduced various substituents, including ethyl, benzyl, n-decane and n-hexadecyl groups attached to the nitrogen atom to give four compounds. In one resonance structure of these molecules, there is one positive charge on the nitrogen atom (Scheme S1†). Therefore we speculate that they can grasp CL to target mitochondria specifically.
In this article, we present the synthesis and characterization of four new polarity sensitive compounds. By analyzing their optical properties, we found these compounds could accurately analyse the dielectric constant of the microenvironment. Further comparison with their localization effect shows that a selected compound termed MCY-BF2 bearing an n-hexadecyl group displays a better mitochondria-targeting capability than the other three compounds. As the first NIR ratiometric fluorescent probe, it was utilized to discriminate the polarity variance between normal and cancer cells. By means of the fluorescence intensity ratio of 795 and 765 nm, the precise mitochondria polarity in different cells and in C. elegans at different developmental stages was also measured. In addition, the polarity difference in normal and tumor s of a mouse was visualized in vivo.
With these compounds in hand, we firstly tested their photophysical properties in detail. The absorption and emission profiles of 1–4 in eight common solvents i.e. water (dielectric constant ε = 80.4), dimethyl sulfoxide (DMSO, ε = 48.9), acetone (ε = 20.7), n-butyl alcohol (NBA, ε = 17.8), dichloroethane (DCE, ε = 10.4), dichloromethane (DCM, ε = 9.14), ethyl ether (ε = 4.34) and dioxane (ε = 2.21) are displayed in Fig. 1, Fig. S1 and Table S1.† As expected, their maximum emission peaks are all in the NIR range (>750 nm). All the emission spectra of 1–4 show dramatic polarity-dependence and the absorption intensity in all the solvents slightly changes (Fig. 1 and S1†). For example, there is a 120-fold increase in the fluorescence intensity in dioxane (ε = 2.21) compared with that in DMSO (ε = 48.9) for MCY-BF2 at 800 nm. These phenomena are in accord with the polarity responsive principle.28 Accompanied by the increase in solvent polarity, all four compounds exhibit a red-shift in the maximum emission wavelength, from about 780 nm in dioxane to about 830 nm in acetone. Meanwhile, the fluorescence quantum yield decreases noticeably with increasing solvent polarity from about 11% in dioxane to about 1.0% in DMSO (Table S1†).
Fig. 1 The normalized absorption and fluorescence spectra of MCY-BF2 (10 μM) in eight solvents with different polarity. The excitation wavelength is 700 nm. |
Next we evaluated the mitochondrial localization ability of the four compounds. Firstly, co-localization imaging experiments were performed in living mouse mammary carcinoma 4T1 cells simultaneously loaded with these compounds and Mito Tracker Green, a commercial mitochondrial dye. As shown in Fig. S2,† all four compounds can readily penetrate into 4T1 cells. By comparing the co-localization effects, MCY-BF2 showed apparently superior mitochondria-targeting ability to compounds 1, 2 and 4. In addition, a similar targeting ability of MCY-BF2 was testified in human hepatoma cells (HepG2) by means of co-localization experiments using Mito Green Tracker (Fig. 2A) and 5,5′,6,6′-tetrachloro-1,1′,3,3′-tetraethylbenzimidazolcarbocyanine iodide (JC-1, Fig. S3†), with a co-localization coefficient of 0.91 and 0.92, respectively. Other subcellular compartment stain experiments using MCY-BF2 and the corresponding commercial organelle-specific dye were then carried out (Fig. S4†). Inside lysosomes (Lyso), endoplasmic reticulum (ER), and Golgi apparatus (Golgi), significantly smaller co-localization coefficient values were found. These results demonstrate that MCY-BF2 can preferentially accumulate in mitochondria. To further verify the mitochondria-targeting mechanism, 4T1 cells treated with the membrane-potential uncoupler 3-chlorophenylhydrazone (CCCP) that can collapse the mitochondrial membrane potential were simultaneously incubated with MCY-BF2 and Mito-Tracker Green. In this experiment, we found that the fluorescence brightness of MCY-BF2 was consistent in the absence or presence of CCCP (Fig. 2B3 and B4). Moreover, the mitochondria-targeting effect of MCY-BF2 is almost unchanged upon treatment with CCCP (Fig. 2B5 and B6). The above results implied that MCY-BF2 might locate in mitochondria in live cells via anchoring CL due to the lipophilic cation group bearing long aliphatic chains, and is independent of the mitochondrial membrane potential. Also, Fig. S5† suggests that MCY-BF2 has low cytotoxicity. On the basis of the above selectivity results, we draw the conclusion that the selected compound MCY-BF2 is a new fascinating probe endowed with polarity sensitivity and excellent mitochondria-targeting ability.
Subsequently, we investigated whether CL could influence the fluorescence of MCY-BF2, since it accumulates in mitochondria in combination with CL. As illustrated in Fig. 3A, upon addition of CL from 0 to 20 μM i.e., the physiological range of CL in mitochondrial membranes,32,33 the fluorescence intensity of MCY-BF2 (10 μM, ε = 80.4) increased slightly. In contrast, MCY-BF2 showed intense fluorescence in a low polarity environment (10 μM, ε = 17) in the presence of 20 μM CL. These results validate that MCY-BF2 was not affected by CL. In addition, interference experiments showed that the fluorescence signal of MCY-BF2 changed very little in the presence of various ROS, nucleophilic thiols, amino acids, different pH buffers and viscosity (Fig. S6–S8†). Further experiments showed that MCY-BF2 had high photostability (Fig. S9†).
To accurately analyze the mitochondrial polarity in living cells and in vivo using MCY-BF2, the curve of the quantitative relationship between the fluorescence intensity ratio and polarity should be examined. For this purpose, we investigated the emission of MCY-BF2 in mixtures of dioxane and water with different proportions of water from 0 to 40% to represent the rise in polarity.34 Fig. S10A† indicates that the absorbance of MCY-BF2 in mixtures of water from 0 to 40% is almost unchanged, whereas, as illustrated in Fig. 3B, the emission maximum wavelength is red-shifted from about 780 nm in dioxane to about 820 nm in 40% water. Notably, there is an approximately 45-fold enhancement in the fluorescence intensity at 780 nm when decreasing the polarity of the solvent from a dielectric constant of 28.1 (40% water) to 2.21 (0% water). The relative fluorescence quantum yield was determined to be 11% in 0% water and 1.1% in 40% water (Fig. S10B†). All the results suggest that MCY-BF2 is extremely sensitive to polarity changes. More importantly, to the best of our knowledge, this is the most sensitive near-infrared fluorescent probe for polarity up to now. By plotting the fluorescence intensity ratio F795/F765 against the dielectric constant (Fig. 3C), a calibration curve was obtained with a relationship coefficient of R2 = 0.99. Thus, it can be used to measure the polarity of certain media or live cells using confocal fluorescence imaging in view of the collection window up to a maximum wavelength of 800 nm. Moreover, Fig. 3C reveals that the F795/F765 ratio increases dramatically from 0.8 to 3.0 with increasing solvent polarity when the dielectric constant is below 15, then the change tends to be gradual when the solvent dielectric constant is above 20, indicating that MCY-BF2 is extraordinarily sensitive to weak polarity media. Taken together, MCY-BF2 is an excellent near-infrared fluorescent probe that can be used to exclusively quantify polarity fluctuations based on changes in its fluorescence intensity ratio F795/F765.
Accumulating evidence suggests that normal and cancer cells display microenvironment differences,35–37 prompting us to exploit the biological feasibility of MCY-BF2 as a ratiometric fluorescence imaging probe. We intend to quantitatively detect mitochondrial polarity in cells using confocal fluorescence imaging in different cells. HepG2 cells and normal human liver cells (HL-7702) were incubated with MCY-BF2 (10 μM), and two fluorescence channels, green for 760–770 nm and red for 790–800 nm, were collected. As illustrated in Fig. 4, the red fluorescence intensity (Fig. 4B and F) was obviously higher. Fig. 4D and H show the fluorescence intensity ratio between the red and green channels, in which a mean ratio was 2.44 ± 0.13 (Fig. 4I) in HepG2 cell mitochondria. The corresponding dielectric constant was 7.72 ± 0.32 according to the fluorescence intensity ratio curve in Fig. 3C. The mean ratio in HL-7702 cell mitochondria is 4.40 ± 0.19, which indicates that the corresponding dielectric constant should be more than 30. Similar results are obtained in 4T1 cells and normal human mammary epithelial cells MCF-10A (Fig. S11†). This demonstrates that polarity in cancer cells is lower than that in normal cells.38–40 All these results substantiated that MCY-BF2 can serve as a highly sensitive ratiometric fluorescence imaging probe to quantitatively indicate the mitochondrial polarity within live cells.
Previous studies speculate that the polarity may change continuously in the C. elegans development process.41,42 To explore whether these inherent polarity differences exist, we used MCY-BF2 to measure the polarity by in vivo visualization of C. elegans at various development stages. C. elegans at embryonic development stage (EDS) and young adult stage (YAS) were incubated with MCY-BF2 (20 μM) for 30 min, after which confocal fluorescence imaging was performed immediately without washing the incubation solution. As shown in Fig. 5, MCY-BF2 can fluoresce well in C. elegans both at EDS and YAS. Interestingly, its fluorescence at EDS (Fig. 5A and B) was remarkably brighter than that at YAS (Fig. 5E and F). To further quantify the precise polarity of C. elegans at EDS and YAS, we investigated the fluorescence ratio based on two groups of confocal fluorescence images captured with λem = 760–770 nm and λem = 790–800 nm. As shown in Fig. 5, the ratio of the two channels at EDS (Fig. 5D) is obviously smaller than that at YAS (Fig. 5H). The mean ratio value of C. elegans at EDS is 2.36 ± 0.05, which corresponds to a dielectric constant of 7.20 ± 0.19. Meanwhile, the mean ratio at YAS is 2.76 ± 0.11, indicating a dielectric constant of 10.07 ± 0.29 (Fig. 5I). This is the first time it has been confirmed that the polarity of C. elegans at EDS is smaller than that at YAS.
One of major advantages of the new MCY-BF2 probe over existing polarity-sensitive probes is that it has both absorption and emission in the NIR region. We consider MCY-BF2 is well suited for biological imaging in live animals because NIR light leads to minimum photodamage to biological samples, deep tissue penetration, and reduced interference from background autofluorescence by biomolecules in living animals.43–45 Thus, a further effort was made to distinguish the polarity variance of normal and tumor tissues in live small animals. We constructed a mouse model of mammary carcinoma for in vivo imaging. Specifically, mammary carcinoma 4T1 cells were inoculated into the neck of mice, and after 10 days a tumor mass was obtained. Subsequently, MCY-BF2 (2 × 10−5 M in PBS containing 1% DMSO, 100 μL) was injected into the tumor-bearing and normal abdomen tissue of the mice, followed by in situ imaging using IVIS Lumina III without shaving the mouses’ skin. The neck tumor mass exhibited a significantly stronger fluorescence (pseudocolor) than that of the normal tissue in the abdomen. The neck tumor tissue displayed an approximately 9-fold higher fluorescence intensity than that of normal tissue (Fig. 6B). We investigated that hypoxia had no effect on the fluorescence of MCY-BF2 (Fig. S12†), further confirming that lower polarity in tumor tissue indeed causes intense fluorescence. These results demonstrate that MCY-BF2 is a prominent fluorescent probe for imaging polarity differences in vivo.
Footnotes |
† Electronic supplementary information (ESI) available: Synthetic procedure for 1–4; NMR and mass spectra of 1–4; spectroscopic properties and confocal imaging. See DOI: 10.1039/c5sc04099j |
‡ These authors contributed equally to the present work. |
This journal is © The Royal Society of Chemistry 2016 |