Issue 7, 2023

Discrimination of Robusta Amazônico coffee farmed by indigenous and non-indigenous people in Amazon: comparing benchtop and portable NIR using ComDim and duplex

Abstract

Robusta Amazônico is the name given to the Amazonian coffee that has been becoming popular and has recently been registered as a geographical indication in Brazil. It is produced by indigenous and non-indigenous coffee producers in regions that are geographically very close to one another. There is a need to authenticate whether coffee is truly produced by indigenous people and near-infrared (NIR) spectroscopy is an excellent technique for this. To meet the substantial trend towards NIR spectroscopy miniaturization, this work compared benchtop and portable NIR instruments to discriminate Robusta Amazônico samples using partial least squares discriminant analysis (PLS-DA). To ensure the results to be fairly comparable and, at the same time, to guarantee representative selection of both training and test set for the discriminant analysis, a sample selection strategy based on coupling ComDim multi-block analysis and the duplex algorithm was applied. Different pre-processing techniques were tested to create multiple matrices to be used in ComDim, as well as to build the discriminant models. The best PLS-DA model for benchtop NIR provided an accuracy of 96% for the test samples, while for the portable NIR the correct classification rate was 92%. It was demonstrated that portable NIR provides similar results to benchtop NIR for coffee origin classification by performing an unbiased sample selection strategy.

Graphical abstract: Discrimination of Robusta Amazônico coffee farmed by indigenous and non-indigenous people in Amazon: comparing benchtop and portable NIR using ComDim and duplex

Article information

Article type
Paper
Submitted
18 Jan. 2023
Accepted
28 Feb. 2023
First published
28 Feb. 2023

Analyst, 2023,148, 1524-1533

Discrimination of Robusta Amazônico coffee farmed by indigenous and non-indigenous people in Amazon: comparing benchtop and portable NIR using ComDim and duplex

M. R. Baqueta, P. Valderrama, E. A. Alves, J. A. L. Pallone and F. Marini, Analyst, 2023, 148, 1524 DOI: 10.1039/D3AN00104K

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements