The introduction of favipiravir as a broad-spectrum antiviral agent, particularly in treating influenza and exploring its potential against COVID-19, emphasizes the necessity for efficient analytical methods. Liquid chromatography has emerged as a commonly utilized technique for quantifying favipiravir in biological fluids. However, the environmental and health concerns linked to classical analytical methods mean a transition toward green analytical chemistry is required. This study investigates the environmental impact of 19 liquid chromatographic methods utilized in the bioanalysis of favipiravir. Recognizing the importance of eco-friendly practices in pharmaceutical analysis, the study employs three widely accepted greenness assessment tools: Analytical Eco-Scale (AES), Green Analytical Procedure Index (GAPI), and Analytical Greenness Calculator (AGREE). Moreover, it incorporates a comprehensive evaluation on a global scale utilizing the whiteness assessment tool Red-Green-Blue 12 (RGB 12). The comprehensive evaluation aims to extend beyond traditional validation criteria and considerations of green chemistry, providing insights into the development of practically efficient, eco-friendly and economical analytical methods for favipiravir determination. This study emphasizes the necessity of planning for the environmental impact and overall sustainability of analytical methods before laboratory trials. Additionally, the integration of greenness/whiteness evaluation in method validation protocols is strongly advocated, emphasizing the importance of critical and global evaluations in analytical chemistry.
In recent years, the need for sustainable analytical methods for favipiravir analysis has become increasingly critical for its precise and reliable quantification in biological fluids. Traditional liquid chromatographic techniques, while effective, often involve the use of hazardous chemicals and generate considerable waste, posing environmental and health risks.5 The adoption of green analytical chemistry principles is essential to mitigate these impacts, ensuring that bioanalytical methods are not only efficient and accurate but also environmentally friendly.6 This necessity drives the development and evaluation of sustainable analytical methods for favipiravir bioanalysis, aiming to align with global sustainability goals and promote safer laboratory practices. Several analytical techniques have been utilized to analyze favipiravir, including spectrophotometry,7–9 spectrofluorimetry,10–12 high performance liquid chromatography – ultraviolet detector (HPLC-UV),13–16 capillary electrophoresis,17 liquid chromatography – tandem mass spectrometry (LC-MS/MS)18–22 and high performance thin liquid chromatography (HPTLC).16 These methods have been applied to pharmaceutical dosage forms7,8,11 and biological fluids such as plasma,13–16,18,19,21,23–30 serum,20,31–33 and milk.29
Green Analytical Chemistry (GAC) has gained attention since 2000, with the goal of establishing safe analytical methodologies for both individuals and the environment.34 The basic principles and recommended practices of GAC aim to strike a balance between effective analyses and safety measures.22,35 These fundamental guidelines of GAC have been widely accepted and published.6 However, there is a lack of standardized tools and procedures to evaluate how ‘green’ an analytical method is ref. 36. These tools help determine if a specific analytical method is environmentally friendly. It is crucial to compare and integrate such evaluation tools as a standard practice during development and validation of novel eco-friendly analytical methods.35 Hence, evaluation tools like the National Environmental Method Index (NEMI),36 Analytical Eco-Scale (AES),37 Green Analytical Procedure Index (GAPI),38 and Analytical Greenness metric (AGREE)39 are commonly employed in recent research to assess the eco-friendliness of methods.22,40–47 They are regarded as crucial for the development and validation of new environmentally sustainable analytical techniques.
Achieving a balance between the eco-friendliness of analytical techniques and their practical effectiveness poses a significant challenge. The utility of a method is determined by several parameters such as analytical efficiency (accuracy, precision, sensitivity), practical and economic considerations (cost, speed, simplicity), and environmental impact. There is a diversity of opinions on how to prioritize greenness in method selection. Some supporters of GAC advocate for prioritizing greenness, while others may consider it only when other parameters are satisfactory. Moreover, the shift towards more environmentally friendly methods necessitates training for operators, and the accessibility of these sustainable approaches can be affected by economic and social factors.48
In the context of this complexity, Sustainable Development (SD) emerges as a multidimensional concept, emphasizing the delicate balance between method effectiveness, practicality and environmental care. The assessment of method sustainability is complicated, and existing greenness assessment tools like NEMI, AES, GAPI, and AGREE may not comprehensively capture all relevant sustainability criteria.48 The suggestion of pre-selecting methods based on other parameters before assessing greenness raises questions about fairness and transparency. Another approach involves employing algorithms for comprehensive assessments of analytical methods on a global scale, such as the Red-Green-Blue (RGB) model.48–50 This model enables expanding the principles of green chemistry to incorporate other primary colors, with red symbolizing analytical efficiency, green representing ecological and safety considerations, and blue denoting productivity and economic viability. In this RGB model, white signifies an ideal method. Consequently, the concept of White Analytical Chemistry (WAC) emerged, consisting of 12 principles similar to the established guidelines of GAC.48 In conclusion, striking a balance between environmental sustainability and practicality in analytical methods requires careful consideration and comprehensive evaluation. Nowak et al. introduced a simplified version of the RGB algorithm, called RGB 12 integrated with WAC.48 This algorithm enables a rapid assessment of methods against the 12 WAC principles, providing a measure of the method's sustainability or “whiteness”. Several publications used the developed model to assess the whiteness profile of their methods.17,30,44,51
It is the responsibility of researchers to evaluate the environmental sustainability and efficiency of newly developed analytical methods. They must consider factors such as environmental impact, human safety, and overall method performance and practicality when choosing the most eco-friendly approach. It is advisable to incorporate clear planning and integrate environmental considerations into method validation protocols to mitigate environmental risks and enhance method efficiency and economic viability. Utilizing various assessment tools can offer a comprehensive understanding of a method's ecological impact.43,52
The objective of this study was to assess the ecological impact of 19 liquid chromatographic methods utilized for the bioanalysis of favipiravir. The evaluation was based on the three widely applied greenness assessment tools: AES, GAPI, and AGREE. Moreover, the study conducted a comprehensive evaluation of all 19 methods using the whiteness assessment tool (RGB 12) after establishing fair rules for scoring all 12 evaluated whiteness criteria to minimize subjectivity. Subsequently, the results were compared with those obtained from the greenness assessment tools. This comprehensive approach aimed to provide an evaluation of methods beyond validation criteria and green chemistry considerations. This study offers valuable insights into the development of more effective, environmentally friendly, economical, and practically efficient analytical methods for the chromatographic bioanalysis of favipiravir.
No. | Extraction technique | Matrix | Sample volume (mL) | Extraction time (min) | Analytes | Analytical technique | Stationary phase | Mobile phase | Column temperature | Flow rate | HPLC run time (min) | Mode of elution | Waste generated (mL) | Ref. |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Fabric phase extraction (FPSE) | Human plasma and breast milk | 0.5 | 60 | Favipiravir | HPLC-UV | C18 (ODS) shim-pack column (150 mm × 4.6 mm × 5 μm) | Acetonitrile-10 mmol L−1 orthophosphoric acid (25:75, v/v) | 30 | 0.8 | 5 | Isocratic | 4.0 | 29 |
2 | Protein precipitation | Human serum and plasma | 0.25 | 11 | Favipiravir | HPLC-MS/MS | Reverse-phase phenomenex C18 column (50 mm × 4.6 mm, 5 μm) | 0.1% formic acid in water – 0.1% formic acid in MOH | 25 | 1 | 4 | Gradient | 4.0 | 32 |
3 | Protein precipitation | Human plasma | 1 | 10.5 | Favipiravir and meropenem | UPLC-UV | BEH C18 | Acetonitrile-potassium dihydrogen phosphate (pH 3) (10:90) | NA | 0.3 | 4.3 | Isocratic | 1.3 | 16 |
4 | Volumetric absorptive microsampling (VAMS) | Whole blood | NA | 51 | Favipiravir | HPLC-UV | C18 column (waters, Sunfire™ 5 μm; 250 × 4.6 mm) | Acetonitrile-0.2% formic acid-20 mmol L−1 sodium dihydrogen phosphate pH 3.5 | 30 | 0.8 | 12 | Gradient | 9.6 | 33 |
5 | Protein precipitation | Mouse and human plasma | 0.1 | 15–17 | Favipiravir | HPLC-MS/MS | Kinetex® F5 column 2.1 × 100 mm 2.6 μm (phenomenex) | 0.1% acetic acid and methanol with 0.1% acetic acid | NA | 0.6 | 3 | Gradient | 1.8 | 23 |
6 | Menthol-assisted LLME | Human plasma | 1.5 | 25 | Favipiravir | HPLC-UV | Thermo® Hypersil ODS C18 column (150 mm × 4.6 mm, 5 μm) | 50 mmol L−1 phosphate buffer (pH = 2.5) and acetonitrile in a ratio of 60:40, v/v | 30 | 1 | 7 | Isocratic | 7.0 | 15 |
7 | Protein precipitation | Human plasma | 0.2 | 15 | Favipiravir | HPLC-UV | Phenomenex Kinetex®, C18 (150 × 4.6 mm, 5 μm) | 0.1% formic acid in water with 0.08% aqueous ammonia, 0.1% formic acid in acetonitrile with 0.08% aqueous ammonia | 40 | 1 | 9 | Gradient | 9.0 | 28 |
8 | QuEChERS | Rat plasma | 0.05 | 60 | Favipiravir, hydroxychloroquine, oseltamivir, and remdesivir | UPLC-MS/MS | Shim-pack GISS C18 column (150 mm × 2.1 mm, 1.9 μm) | Water and acetonitrile, both with 0.1% (v/v) formic acid | 45 | 0.25 | 13 | Gradient | 3.25 | 18 |
9 | Protein precipitation | Human plasma | 1 | 11 | Favipiravir, remdesivir and dexamethasone | UPLC-UV | Reversed phase BEH C18 (150 mm × 2.1 mm, 1.7 μm) | Methanol, acetonitrile and water acidified with orthophosphoric acid (pH 4) as a mobile phase in the following ratio: (15:35:50, by volume) | 25 | 0.3 | 4.33 | Isocratic | 1.3 | 27 |
10 | A gadolinium-based magnetic ionic liquid for supramolecular dispersive liquid–liquid microextraction (DLLME) | Human plasma | 2–3 mL | 12 | Favipiravir | HPLC-UV | Thermo® Hypersil ODS C18 column (150 × 4.6 mm, 5 μm) | 50 mmol L−1 phosphate buffer (pH = 2.5) and acetonitrile in a 60:40, v/v | 30 | 1 | 5 | Isocratic | 5 | 13 |
11 | Liquid–liquid extraction (LLE) | Spiked human plasma | 1 | 40 | Favipiravir | HPLC-UV | Symmetry® C18-(250 mm 4.6 mm, 5 μm particle size) | Methanol/acetonitrile:20 mmol L−1 phosphate buffer (pH 3.1) 30:10:60, v/v/v | NA | 1 | 12 | Isocratic | 12 | 25 |
12 | Protein precipitation | Human plasma | 0.5 | 9 | Favipiravir | HPLC-MS/MS | Eclipse plus C18column (50 × 4.6 mm, 3.5 μm) | Methanol-0.2% acetic acid (20:80, v/v) | 25 | 0.6 | 3 | Isocratic | 1.8 | 21 |
13 | Protein precipitation | Human plasma | 0.2 | 6 | Favipiravir | UPLC-MS/MS | Acquity UPLC® HSS C18 (100 × 2.1 mm, 1.8 μm) | 10 mmol L−1 ammonium formate + 0.1% formic acid: methanol | 25 | 0.35 | 4.5 | Gradient | 1.6 | 26 |
14 | Protein precipitation then online solid phase extraction (SPE) | Human serum | 0.05 | 5 | Favipiravir, remdesivir and its active metabolite, chloroquine, hydroxychloroquine, lopinavir, ritonavir, and azithromycin | 2D-HPLC-MS/MS | MassTox® TDM MasterColumn® series A (chromsystems) | Loading pump: phase A1 water and B1 acetonitrile-formic acid (99.9:0.01, v/v) eluting pump: phase A2 MassTox® TDM series A mobile phase 1 and phase B2 MassTox® TDM series A mobile phase 2 (chromsystems) | NA | 0.6 | 5 | Gradient | 3 + 6 for online SPE | 20 |
15 | Homogeneous liquid–liquid microextraction (LLME) | Human plasma | 1.5 | 13 | Favipiravir | HPLC-UV | Hypersil ODS C18 column (150 mm × 4.6 mm, 5 μm) | 60% of aqueous phosphate buffer (50 mmol L−1, pH was adjusted to 2.5): 40% acetonitrile | 30 | 1 | 5 | Isocratic | 5 | 14 |
16 | Protein precipitation | Human plasma | 0.2 | 20.5 | Favipiravir | UPLC-MS/MS | Acquity UPLC BEH HILIC column (2.1 × 100 mm, 1.7 μm) | Acetonitrile and 0.005% ammonia in water (75:25, v/v) | 40 | 0.25 | 2 | Isocratic | 0.5 | 19 |
17 | SPE | Human serum | 0.15 | 4 | Favipiravir | HPLC-UV | Chromolith high resolution RP-column (100 × 4.6 mm) | 0.1% phosphoric acid/acetonitrile (95:5) | 30 | 2 | 3 | Isocratic | 6 | 31 |
18 | LLE | Spiked human plasma | 2 | 40 | Favipiravir | HPLC-UV | Chromasil C18 (250 × 4.6 mm × 5 μm) | Methanol/water, 35:65, pH 3 | 40 | 0.8 | 9.39 | Isocratic | 7.5 | 24 |
19 | Protein precipitation | Spiked human plasma | 1 | 40 | Favipiravir, aspirin, atenolol, atorvastatin, losartan and remdesivir | UPLC-UV | ACQUITY UPLC® BEH C18 (2.1 × 150 mm, and 1.7 μm particle size)` | 0.03 mol L−1 Brij-35, 0.15 mol L−1 sodium dodecyl sulfate, and 0.02 mol L−1 sodium dihydrogen phosphate (pH 5.0) as the mobile phase A (90%) and n-propanol as the mobile phase B (10%) | 30 | 0.5 (5.5 min) 0.8 (2.5 min) | 8 | Isocratic | 4.25 | 30 |
Method | Analytical eco-scale | GAPI | AGREE | Ref. | |
---|---|---|---|---|---|
a PPs for analytical eco-scale were calculated as per ref. 37 as follows: (1) reagent amount PPs: <10 mL (g) = 1; 10–100 mL (g) = 2; >100 mL (g) = 3. (2) Reagent hazard PPs: none = 0; less severe = 1; more severe = 2. Then total PPs = amount PPs × hazard PPs. (3) Energy PPs: ≤ 0.1 kWh per sample = 0, ≤ 1.5 kWh per sample = 1, > 1.5 kWh per sample = 2. (4) Occupational hazard PPs: analytical process hermitization = 0; emission of vapors and gases to air = 3. (5) Waste PPs: none = 0; <1 mL (g) = 1; 1–10 mL (g) = 3; >10 mL (g) = 5. | |||||
1 | Reagents | PPsa | 29 | ||
Polycaprolactone-block-polydimethylsiloxane-block-polycaprolactone polymer | 0 | ||||
Methyl trimethoxysilane | 2 | ||||
Acetone | 4 | ||||
Methylene chloride | 2 | ||||
Trifluoroacetic acid | 4 | ||||
Methanol | 6 | ||||
Acetonitrile | 4 | ||||
Phosphoric acid | 2 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
Conditioning device (50 C × h) | 2 | ||||
Ultrasonic bath | 2 | ||||
Magnetic stirring | 0 | ||||
HPLC-UV | 1 | ||||
Occupational hazard | 0 | ||||
Waste | 0 | ||||
Total PPs | 29 | ||||
Eco-scale | 71 | ||||
2 | Reagents | PPs | 32 | ||
Acetonitrile | 4 | ||||
Formic acid | 6 | ||||
Methanol | 6 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
LC-MS/MS | 2 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 21 | ||||
Eco-scale | 79 | ||||
3 | Reagents | PPs | 16 | ||
Acetonitrile | 4 | ||||
Phosphoric acid | 2 | ||||
Potassium dihydrogen orthophosphate | 0 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
UHPLC | 0 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 9 | ||||
Eco-scale | 91 | ||||
4 | Reagents | PPs | 33 | ||
Acetonitrile | 4 | ||||
Formic acid | 6 | ||||
Sodium dihydrogen phosphate | 0 | ||||
Methanol | 6 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
Ultrasonic bath | 0 | ||||
HPLC-DAD | 1 | ||||
Solvent evaporator | 2 | ||||
Occupational hazard | 3 | ||||
Waste | 5 | ||||
Total PPs | 27 | ||||
Eco-scale | 73 | ||||
5 | Reagents | PPs | 23 | ||
Methanol | 6 | ||||
Acetic acid | 4 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
Solvent evaporator | 2 | ||||
LC-MS/MS | 2 | ||||
Occupational hazard | 3 | ||||
Waste | 3 | ||||
Total PPs | 20 | ||||
Eco-scale | 80 | ||||
6 | Reagents | PPs | 15 | ||
Tetrahydrofuran | 6 | ||||
Menthol | 1 | ||||
Trichloroacetic acid | 4 | ||||
Acetonitrile | 4 | ||||
Potassium dihydrogen phosphate | 0 | ||||
Phosphoric acid | 2 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
HPLC-UV | 1 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 21 | ||||
Eco-scale | 79 | ||||
7 | Reagents | PPs | 28 | ||
Acetonitrile | 4 | ||||
Formic acid | 6 | ||||
Ammonia | 6 | ||||
Methanol | 6 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
HPLC-UV | 1 | ||||
Occupational hazard | 3 | ||||
Waste | 3 | ||||
Total PPs | 29 | ||||
Eco-scale | 71 | ||||
8 | Reagents | PPs | 18 | ||
Acetonitrile | 4 | ||||
Formic acid | 6 | ||||
NaCl | 0 | ||||
Anhydrous magnesium sulphate | 0 | ||||
Methanol | 6 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
UHPLC-MS/MS | 2 | ||||
Solvent evaporator | 2 | ||||
Occupational hazard | 3 | ||||
Waste | 3 | ||||
Total PPs | 26 | ||||
Eco-scale | 74 | ||||
9 | Reagents | PPs | 27 | ||
Acetonitrile | 4 | ||||
Phosphoric acid | 2 | ||||
Methanol | 6 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
UHPLC-UV | 0 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 15 | ||||
Eco-scale | 85 | ||||
10 | Reagents | PPs | 13 | ||
Acetonitrile | 4 | ||||
Phosphoric acid | 2 | ||||
Gadolinium(III) chloride hexahydrate | 1 | ||||
Trihexyl (tetradecyl)phosphonium chloride | 4 | ||||
Dichloromethane | 4 | ||||
Perchloric acid | 4 | ||||
Tetrahydrofuran | 6 | ||||
Instruments | |||||
Reflux | 2 | ||||
Vacuum evaporator (drying) | 2 | ||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
HPLC-UV | 1 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 33 | ||||
Eco-scale | 67 | ||||
11 | Reagents | PPs | 25 | ||
Acetonitrile | 4 | ||||
Methanol | 6 | ||||
Phosphate buffer | 0 | ||||
Dichloromethane | 4 | ||||
Instruments | |||||
Solvent evaporator | 2 | ||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
HPLC-UV | 1 | ||||
Occupational hazard | 3 | ||||
Waste | 5 | ||||
Total PPs | 25 | ||||
Eco-scale | 75 | ||||
12 | Reagents | PPs | 21 | ||
Methanol | 6 | ||||
Acetic acid | 4 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
LC-MS/MS | 2 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 15 | ||||
Eco-scale | 85 | ||||
13 | Reagents | PPs | 25 | ||
Methanol | 6 | ||||
Formic acid | 6 | ||||
Ammonium format | 1 | ||||
Acetonitrile | 4 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
LC-MS/MS | 2 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 22 | ||||
Eco-scale | 78 | ||||
14 | Reagents | PPs | 20 | ||
Acetonitrile | 4 | ||||
Formic acid | 6 | ||||
Methanol | 6 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
LC-MS/MS | 2 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 21 | ||||
Eco-scale | 79 | ||||
15 | Reagents | PPs | 14 | ||
Acetonitrile | 4 | ||||
Phosphoric acid | 2 | ||||
Perchloric acid | 4 | ||||
Tetrahydrofuran | 6 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
HPLC-UV | 1 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 20 | ||||
Eco-scale | 80 | ||||
16 | Reagents | PPs | 19 | ||
Acetonitrile | 4 | ||||
Ammonia | 6 | ||||
Methanol | 6 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
UHPLC-MS/MS | 2 | ||||
Occupational hazard | 3 | ||||
Waste | 3 | ||||
Total PPs | 24 | ||||
Eco-scale | 76 | ||||
17 | Reagents | PPs | 31 | ||
Acetonitrile | 4 | ||||
Phosphoric acid | 2 | ||||
HCl | 4 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
HPLC-UV | 1 | ||||
Occupational hazard | 0 | ||||
Waste | 3 | ||||
Total PPs | 14 | ||||
Eco-scale | 86 | ||||
18 | Reagents | PPs | 24 | ||
Methanol | 6 | ||||
Ethyl acetate | 4 | ||||
Phosphoric acid | 2 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
Solvent evaporator | 2 | ||||
HPLC-UV | 1 | ||||
Occupational hazard | 3 | ||||
Waste | 3 | ||||
Total PPs | 21 | ||||
Eco-scale | 79 | ||||
19 | Reagents | PPs | 30 | ||
Brij-35 | 4 | ||||
Methanol | 6 | ||||
Sodium dodecyl sulfate | 4 | ||||
Sodium dihydrogen phosphate | 0 | ||||
Propanol | 6 | ||||
Instruments | |||||
Vortex | 0 | ||||
Centrifuge | 0 | ||||
Solvent evaporator | 2 | ||||
UPLC-UV | 0 | ||||
Occupational hazard | 3 | ||||
Waste | 3 | ||||
Total PPs | 28 | ||||
Eco-scale | 72 |
Method | Category | Assessment | GAPI pictograms | Ref. |
---|---|---|---|---|
1 | Sample preparation | 29 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | Under normal conditions (yellow) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤ 1.5 kW h per sample (yellow) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
2 | Sample preparation | 32 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (yellow) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | > 1.5 kW h per sample (red) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
3 | Sample preparation | 16 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Simple treatment (yellow) | |||
Scale of extraction (6) | Macro-extraction (red) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤0.1 kW h per sample (green) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
4 | Sample preparation | 33 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | Simple treatment (yellow) | |||
Reagent and solvents | ||||
Amount (9) | 10–100 mL (yellow) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤1.5 kW h per sample (yellow) | |||
Occupational hazard (13) | Emission of vapours to the atmosphere (red) | |||
Waste (14) | >10 mL (red) | |||
Waste treatment (15) | No treatment (red) | |||
5 | Sample preparation | 23 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | Simple treatment (yellow) | |||
Reagent and solvents | ||||
Amount (9) | <10 mL (green) | |||
Health hazard (10) | NFPA = 1, slight toxicity (green) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | >1.5 kW h per sample (red) | |||
Occupational hazard (13) | Emission of vapours to the atmosphere (red) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
6 | Sample preparation | 15 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: Direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | Simple treatment (yellow) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤1.5 kW h per sample (yellow) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
7 | Sample preparation | 28 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | Under normal conditions (yellow) | |||
Type of method: Direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | 10–100 mL (yellow) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤1.5 kW h per sample (yellow) | |||
Occupational hazard (13) | Emission of vapours to the atmosphere (red) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
8 | Sample preparation | 18 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | Under normal conditions (yellow) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | Simple treatment (yellow) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | >1.5 kW h per sample (red) | |||
Occupational hazard (13) | Emission of vapours to the atmosphere (red) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
9 | Sample preparation | 27 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | Under normal conditions (yellow) | |||
Type of method: direct or indirect (5) | Simple procedures (yellow) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | <10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤0.1 kW h per sample (green) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
10 | Sample preparation | 13 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: Direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | <10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤1.5 kW h per sample (yellow) | |||
Occupational hazard (13) | Emission of vapours to the atmosphere (red) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
11 | Sample preparation | 25 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Macro-extraction (red) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | Simple treatments (yellow) | |||
Reagent and solvents | ||||
Amount (9) | 10–100 mL (yellow) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤1.5 kW h per sample (yellow) | |||
Occupational hazard (13) | Emission of vapours to the atmosphere (red) | |||
Waste (14) | > 10 mL (red) | |||
Waste treatment (15) | No treatment (red) | |||
12 | Sample preparation | 21 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 1, slight toxicity (green) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | >1.5 kW h per sample (red) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
13 | Sample preparation | 26 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Macro-extraction (red) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | >1.5 kW h per sample (red) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
14 | Sample preparation | 20 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Macro-extraction (red) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | >1.5 kW h per sample (red) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
15 | Sample preparation | 14 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤1.5 kW h per sample (yellow) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
16 | Sample preparation | 19 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | <10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | >1.5 kW h per sample (red) | |||
Occupational hazard (13) | Emission of vapours to the atmosphere (red) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
17 | Sample preparation | 31 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Micro-extraction (yellow) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | None (green) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤1.5 kW h per sample (yellow) | |||
Occupational hazard (13) | Hermetic sealing of analytical procedure (green) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
18 | Sample preparation | 24 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | None (green) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Macro-extraction (red) | |||
Solvents/reagents used (7) | Green solvents/reagents used (yellow) | |||
Additional treatments (8) | Simple treatments (yellow) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 1, slight toxicity (green) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤1.5 kW h per sample (yellow) | |||
Occupational hazard (13) | Emission of vapours to the atmosphere (red) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) | |||
19 | Sample preparation | 30 | ||
Collection (1) | Offline (red) | |||
Preservation (2) | None (green) | |||
Transport (3) | Required (yellow) | |||
Storage (4) | Under normal conditions (yellow) | |||
Type of method: direct or indirect (5) | Extraction required (red) | |||
Scale of extraction (6) | Macro-extraction (red) | |||
Solvents/reagents used (7) | Non-green solvents/reagents used (red) | |||
Additional treatments (8) | Simple treatments (yellow) | |||
Reagent and solvents | ||||
Amount (9) | < 10 mL (green) | |||
Health hazard (10) | NFPA = 2, moderate toxicity (yellow) | |||
Safety hazard (11) | NFPA = 3, high flammability (yellow) | |||
Instrumentation | ||||
Energy (12) | ≤0.1 kW h per sample (green) | |||
Occupational hazard (13) | Emission of vapours to the atmosphere (red) | |||
Waste (14) | 1–10 mL (yellow) | |||
Waste treatment (15) | No treatment (red) |
Assessment of whiteness profiles was conducted using the RBG 12 algorithm. The assessment procedure involved assigning scores to all 19 methods, evaluating each attribute.48 The ‘red’ criteria included the following: application scope – R1 (including the number of determined analytes), lower limit of quantification (LLOQ) – R2, precision – R3, accuracy – R4. For the ‘green’ criteria, the selected aspects were toxicity of reagents measured by the number of Globally Harmonized System of Classification and Labelling of Chemicals (GHS) pictograms of the employed reagents – G1, quantity of reagents and waste produced – G2, consumption of energy – G3, direct impact on the user (safety or occupational hazards) – G4. Regarding the ‘blue’ criteria: cost efficiency – B1, time efficiency – B2, requirements including sample amount utilized for analysis and other needs such as advanced instruments and skills personnel– B3, and operational simplicity including miniaturization, integration and degree of automation – B4.
As WAC concept is relatively new, there are not established and universally accepted rules for assessing these methods yet.53 So, scoring these criteria is mostly based on subjective judgment, although efforts are made to ensure a comprehensive assessment. In this study, efforts were made to make the assessment as fair as possible, and specific rules were set for each evaluated method to determine their scores. Although the choice of rules might have some subjectivity, it is enough to make a reasonable comparison between methods. The scoring rules used to evaluate analytical methods for favipiravir in biological matrices are detailed in file 2 of the ESI.† Calculations were conducted using an Excel spreadsheet.48 Fig. 2 shows the assessment results of the 19 methods, illustrating the outcomes for each method, while a comparison between main assessment outcomes is illustrated in Fig. 3. All whiteness assessment calculations using the Excel spreadsheet are presented in file 3 of the ESI.†
The comparison of the eco-friendliness of the 19 methods using GAPI and AGREE metrics revealed that Method 3 emerged as the most eco-friendly approach for determining favipiravir in biological matrices. It exhibited the highest greenness profile as determined by both the GAPI and AGREE tools, with 6 green pictograms in GAPI and the highest AGREE score of 0.65, further substantiating its superior environmental performance. Method 12 secured the second position, displaying 6 green pictograms in GAPI and an AGREE score of 0.56. Similarly, Method 9 and Method 17 exhibited favorable environmental characteristics, each acquiring 5 green pictograms in GAPI and AGREE scores of 0.61 and 0.60, respectively.
It is important to note that the lower AGREE score of Method 12, compared to Methods 9 and 17, can be attributed to the utilization of LC-MS/MS, which enhanced the method sensitivity. This methodological choice introduced specific elements that contributed to the reduction in its overall AGREE score. This finding highlights the impact of methodological decisions on environmental assessments, prompting further consideration of the trade-offs involved in selecting sensitivity-enhancing techniques.
Conversely, Method 19 exhibited the least environmentally friendly profile among the evaluated methods, attaining only 2 green pictograms in GAPI. Additionally, it received the lowest AGREE score of 0.53, indicating a comparatively lower level of environmental sustainability. This can be attributed primarily to the use of lengthy extraction procedures involving hazardous organic solvents and extended elution times for chromatographic separation, resulting in high amounts of hazardous solvents (Table 1).
The AES tool further substantiated the superior environmental performance of Method 3 (91), emphasizing the need for a multi-faceted evaluation to achieve a comprehensive understanding of the ecological impact of analytical methods. It was followed by Method 17, with a score of 86, and Methods 9 and 12, both scoring 85. The least environmentally friendly method was Method 10, with a score of 67. These findings emphasize the complex relationship between methodological choices and environmental sustainability, guiding future considerations in method selection and development.
Contrary to the greenness assessment results, according to RGB 12 analysis, Method 9 achieved the highest whiteness score (93.5%). Method 3 secured the second-highest position with a whiteness score of 91.8%, closely followed by Method 5 in third place with a whiteness score of 91.4%. Below is a detailed explanation of the whiteness assessment results for all criteria.
Method 4 (HPLC-UV), despite exhibiting good precision (i.e., < 10%), demonstrated poor accuracy (i.e., 69–73%), limited scope of application, and a high LLOQ (i.e., 500 ng mL−1), resulting in the lowest CSred value among all 19 methods (i.e., 83.8%).
The lowest CSgreen value was obtained by Method 10 (HPLC-UV), 77.3%. Although the occupational hazards were low – exposure to high temperature (during reflux) – reagents toxicity, consumption of energy and waste generation were high. This correlated with the extensive use of reagents during the preparation of the gadolinium-based magnetic ionic liquid.13
Methods 10 (HPLC-UV), 14 (2D-LC-MS/MS), 15 (HPLC-UV), and 17 (HPLC-UV) attained third place, each achieving a CSblue value of 92.5%. While Methods 10, 15, and 17 employed cost-effective HPLC-UV technology, Method 14 utilized a more expensive and sophisticated MS/MS detector, requiring skilled personnel for operation. However, Method 14 demonstrated time efficiency, with a total sample preparation and analysis time of 10 minutes and employed online solid-phase extraction (SPE) sample preparation, contributing to its method score in terms of automation. As a result, all four methods tied for third place with the same CSblue score. Method 8 obtained the lowest CSblue score (i.e., 87.5%), primarily attributed to the use of expensive LC-MS/MS equipment, which also required skilled personnel for operation, thus reducing the method score. Moreover, the method's sample preparation and analysis time was lengthy (approximately 73 min per sample), and the absence of integration further contributed to the reduction in the method's CSblue score.
Overall, Method 9 exhibited the best whiteness profile results, achieving high scores for the red, green, and blue attributes. It secured second place for the red and green attributes, and also placed second after Methods 3 and 7 in the blue attributes. Method 3, the second-ranked method, outperformed Method 9 in the green and blue aspects but lagged behind in the red criteria (i.e., method performance), primarily due to the high LLOQ (i.e., 2000–5000 ng mL−1 compared to 100 ng mL−1 for Method 9) and lower accuracy (i.e., 82–103% for Method 3 compared to 98–103% for Method 9). This resulted in an overall red score (CSred) of 85 and 95 for Methods 3 and 9, respectively, contributing to the overall whiteness score of 93.5% for Method 9, placing it in the first position ahead of Method 3 with 91.8%, which was ranked second in the overall whiteness score.
The data depicted in Fig. 2 and 3 illustrate the difference in ratings across all assessment criteria for individual methods, and a comparison between the main assessment outcomes of all 19 methods. In addition, Table S2 in file 4 of the ESI† presents the ranking of all 19 methods based on the red, green, blue, and overall whiteness criteria. Method 5 secured third place with a whiteness score of 91.4%, followed closely by Method 15 (90.9%). While both methods excelled in method performance (red criteria) and practical effectiveness (blue criteria), achieving scores of 91.3% and 92.5% for the blue criteria for Methods 5 and 15, respectively, as well as 93.8% for the red criteria for both methods, they showed comparatively lower performance in the green criteria, with scores of 89.2% and 86.5%, respectively. The poorest overall whiteness profile was obtained by Method 11 (84.4%), displaying poor method greenness and performance criteria with scores of 79.6% and 85.0%, respectively. This can be attributed to several factors, including the high LLOQ of the HPLC-UV method utilized (i.e., 3100 ng mL−1), limited scope of application, toxicity, and the excessive amounts of reagents used, resulting in high waste generation.25
In conclusion, a comprehensive analysis of the results obtained from both the greenness and whiteness assessment for the 19 methods provided insights into their environmental and functional aspects. The greenness assessment, incorporating metrics such as GAPI and AGREE, identified Method 3 as the most eco-friendly method. However, the whiteness assessment ranked this method as the second-best, placing Method 9 in the top position. Method 9 also ranked third according to ASE, GAPI, and AGREE metric assessments. This indicates that factors such as method performance (red criteria) and practicality (blue criteria) play a significant role in the overall assessment of analytical methods.
Conversely, Method 12 exhibited an excellent ASE score of 85, securing third place among all 19 methods. However, its AGREE score of 0.56 placed it at the eleventh position. Interestingly, GAPI results highlighted Method 12 with 6 green pictograms, emphasizing its status as one of the best environmentally friendly methods among all 19 methods. In the whiteness assessment, the overall score of 89.2% positioned Method 12 at the seventh place, a result that aligns well with the AGREE evaluation. This can be explained because Method 12 utilized LC-MS/MS technique, which can enhance method performance (sensitivity and selectivity), but on the other hand, could negatively impact the method's greenness profile by increasing energy consumption. In addition, the use of expensive LC-MS/MS instrumentation would affect the method sustainability, specifically the blue score, due to the financial resources required for instrument acquisition and maintenance, as well as the need for skilled personnel for operation and data interpretation. As a result, Method 12 secured the thirteenth place in the blue criteria and the seventh place in the overall whiteness assessment due to its enhanced method performance (red criteria) attributed to the utilization of LC-MS/MS technology.
These findings support the conclusion that to develop a sustainable method for the bioanalysis of favipiravir, it is crucial to employ short sample preparation and analysis times using a cost-effective analytical technique such as LC-UV, with proper optimization of column selection, mobile phase composition, and automation. The utilization of LC-MS/MS, while enhancing sensitivity and selectivity, has drawbacks, including increased energy consumption and high costs associated with instrumentation and maintenance. However, in cases where very low limits of detection or enhanced selectivity are required, LC-MS/MS becomes indispensable despite these drawbacks. This highlights the need for a balanced approach that prioritizes sustainability whenever possible.
Finally, the summary of the above findings, collectively stresses the importance of a holistic approach in method evaluation, acknowledging the broader sustainability implications beyond just environmental considerations. The comprehensive insights provided by both greenness and whiteness assessments guide a more informed and balanced selection of analytical methods, ensuring integration of environmental responsibility, analytical performance, and practical efficiency.
The primary advantage of GAPI is its comprehensive assessment of the entire analytical processes. It considers all relevant factors including sample preparation, transportation, reagents, and analytical instruments. In addition, GAPI is highly efficient in the comparative analysis of multiple analytical methods, aiding in the selection of the most environmentally friendly option. It provides detailed information for every step of the analytical process, highlighting areas that require improvement for enhanced greenness. However, the main disadvantage of GAPI is its complexity compared to AES.38
AGREE's primary advantage is its ability to highlight the strengths and weaknesses across the twelve principles of GAC.39 In addition, its overall score provides both quantitative and qualitative information regarding GAC principles. AGREE is preferred over AES due to its consideration of factors such as sample size, sample throughput (number of samples analyzed per hour), the use of bio-based solvents, and the presence of toxic reagents to aquatic life. Moreover, AGREE is favored over GAPI for its simplicity, automation, and quantitative results, enabling comparable conclusions regarding the ecological impact of methods with reduced effort.
Overall, it is recommended to use more than one greenness assessment tool to obtain a comprehensive assessment of a method's greenness profile. However, even when combined, these metrics still lack consideration for essential sustainability aspects such as method performance and cost-effectiveness.
On the other hand, whiteness assessment, utilizing the WAC concept (RGB12 metric), offers a more comprehensive view by considering not only ecological aspects but also analytical and practical parameters. However, it is noteworthy that while the whiteness assessment using RGB12 tool provides the most comprehensive evaluation, incorporating method performance and effectiveness in addition to the method's green aspects, its main limitation lies in subjectivity. This subjectivity can arise from the interpretation of scoring criteria and the weighting of different metrics, which may vary among evaluators. To address this limitation, establishing well-defined scoring criteria and guidelines for interpretation could enhance objectivity and consistency in whiteness assessment. One solution could involve the development of automated tools for calculations, which would reduce the potential for human bias and facilitate standardized scoring across different evaluations. These automated tools could incorporate predefined scoring algorithms based on agreed-upon criteria, ensuring uniformity in assessment outcomes. In addition, providing clear explanations and examples for each scoring criterion could help mitigate subjectivity by ensuring evaluators have a common understanding of how to apply the criteria in practice. By addressing the subjectivity issue and enhancing the objectivity of whiteness assessment using the RGB12 tool, researchers and laboratories can more confidently utilize this comprehensive evaluation tool to inform method selection and promote the development of sustainable and efficient analytical practices.
Greenness assessment tools indicated that Method 3 was the most eco-friendly among the 19 methods, while the whiteness assessment revealed that Method 9 performed the best due to its superior method performance, time and cost efficiency, and good greenness profile. This highlights the crucial link between environmental responsibility and method quality, emphasizing the importance of considering broader sustainability aspects.
The AES metric provides a straightforward, semi-quantitative assessment of analytical methods based on reagent usage and waste generation, but it lacks detailed explanations of non-eco-friendly aspects. GAPI offers a comprehensive analysis of entire processes, while AGREE highlights strengths and weaknesses across GAC principles and provides both quantitative and qualitative information. Whiteness assessment using the RGB12 metric is comprehensive but subjective, necessitating well-defined criteria and automated tools for enhanced objectivity and consistency.
Developing sustainable and efficient analytical methods for favipiravir bioanalysis can be enhanced by exploring alternative greener solvents, such as natural deep eutectic solvents or those derived from renewable resources, to replace conventional organic solvents in sample preparation. This reduces environmental impact and health risks. In addition, utilizing miniaturized and automated techniques, such as chip-based separation systems, can minimize solvent and sample consumption, reduce waste, and enhance throughput. Methods that support in situ analysis should also be considered. Integrating green sample preparation methods, like solid-phase microextraction (SPME) and dispersive liquid–liquid microextraction (DLLME), can further enhance the process and reduce solvent use. Furthermore, optimizing chromatographic conditions, including column selection and mobile phase composition, can improve separation efficiency, reduce analysis time, and minimize solvent consumption.