Issue 40, 2024

High-performance electrochemical immunosensor based on bimetallic gold/silver functionalized carbon spheres for CYFRA 21-1 detection and information protection

Abstract

Bimetallic nanomaterial-based systems have been widely utilized across various fields due to their remarkable expandability and flexibility, including nanomedicine, diagnostics, and molecular information technology. Here, we constructed an electrochemical immunosensor using bimetallic gold/silver functionalized carbon spheres (AuAg@CSs) and mesoporous silica nanoparticles (MSNs) for the sensitive determination of cytokeratin 19 fragment antigen 21-1 (CYFRA 21-1) and ensuring information protection for textual data. The AuAg@CSs demonstrated exceptional catalytic activity towards hydrogen peroxide, generating a significant current signal. The introduction of CYFRA 21-1 facilitated the binding of MSNs, thereby forming a sandwich-type electrochemical immunosensor that resulted in a notable decrease in current. Notably, the detection limit for CYFRA 21-1 was determined to be 31 fg mL−1, accompanied by high selectivity. Furthermore, extensive textual information can be encrypted and concealed within the current responses of the electrochemical nanosensing system. By establishing a threshold, these current signals can be represented as a series of binary strings, which can subsequently be segmented into shorter strings. Through information coding methods, these shorter binary strings can be assembled and decrypted, ultimately merging into meaningful textual content. This study promotes the synthesis and multifunctional application of bimetallic nanomaterials, providing innovative solutions to enhance the sensing sensitivity of electrochemical immunosensors and paving the way for advancements in molecular digitization.

Graphical abstract: High-performance electrochemical immunosensor based on bimetallic gold/silver functionalized carbon spheres for CYFRA 21-1 detection and information protection

Supplementary files

Article information

Article type
Paper
Submitted
21 Leq 2024
Accepted
06 Way 2024
First published
09 Way 2024

Anal. Methods, 2024,16, 6802-6809

High-performance electrochemical immunosensor based on bimetallic gold/silver functionalized carbon spheres for CYFRA 21-1 detection and information protection

L. S. Wang, Y. J. Guo, Y. H. Li, Y. S. Zhao, Q. Wei and Z. F. Gao, Anal. Methods, 2024, 16, 6802 DOI: 10.1039/D4AY01550A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements