Open Access Article
Yongkang
Wang
,
Yuki
Nagata
and
Mischa
Bonn
*
Molecular Spectroscopy Department, Max Planck Institute for Polymer Research, Ackermannweg 10, 55128 Mainz, Germany. E-mail: bonn@mpip-mainz.mpg.de
First published on 20th June 2023
Graphene, a transparent two-dimensional (2D) conductive electrode, has brought extensive new perspectives and prospects to electrochemical systems, such as chemical sensors, energy storage, and energy conversion devices. In many of these applications, graphene, supported on a substrate, is in contact with an aqueous solution. An increasing number of studies indicate that the substrate, rather than graphene, determines the organization of water in contact with graphene, i.e., the electric double layer (EDL) structure near the electrified graphene, and the wetting behavior of the graphene: the graphene sheet is transparent in terms of its supporting substrate. By applying surface-specific heterodyne-detected sum-frequency generation (HD-SFG) spectroscopy to the silicon dioxide (SiO2)-supported graphene electrode/aqueous electrolyte interface and comparing the data with those for the calcium fluoride (CaF2)-supported graphene [Y. Wang et al., Angew. Chem., Int. Ed., 2023, 62, e202216604], we discuss the impact of the different substrates on the charging of both the graphene and the substrate upon applying potentials. The SiO2-supported graphene shows pseudocapacitive behavior, consistent with the CaF2-supported graphene case, although the surface charges on SiO2 and CaF2 differ substantially. The SiO2 surface is already negatively charged at +0.57 V (vs. Pd/H2), and the negative surface charge is doubled when negative potentials are applied, in contrast with the CaF2 case, where the positive charge is reduced when negative potentials are applied. Interestingly, the charging of the graphene sheet is almost identical between the negatively charged SiO2 surface and positively charged CaF2 surface, demonstrating that the graphene charging is decoupled from the charging of the substrates.
An increasing number of studies have indicated that the graphene sheet cannot shield the substrate's surface charge from the aqueous electrolyte, known as the “wetting translucency”.20–22 As a result, the substrate's surface charges greatly contribute to the local electric field and strongly affect the organization of water and electrolyte ions in the EDL.10,20,23 We have recently shown that water dissociation caused by the applied potentials on the graphene electrode changes the local pH near the CaF2-supported graphene electrode.10 Aqueous proton permeation through the monolayer graphene electrode24–27 induces the chemical reaction at the CaF2 surface, altering the surface charge of the CaF2 substrate.10,20,23 A question arising here is whether such a chemical reaction-induced surface charge variation is a universal observation for substrate-supported graphene electrodes.
Here, we probe the charging of the SiO2 supported-graphene electrode/aqueous electrolyte interface under potentiostatically controlled conditions using heterodyne-detected sum-frequency generation (HD-SFG) spectroscopy employing the interfacial water signal (χ(2)). HD-SFG spectroscopy is a surface-specific technique that selectively probes molecular vibrations from molecules at the interface. Signals from the bulk are naturally excluded due to the selection rule.28,29 Importantly, the complex χ(2) signal of the interfacial water provides insights not only into the molecular structure and orientation of the interfacial water,30,31 but also the charges at the interface.32,33 By this, we are able to directly probe the charging of the interface under potentiostatically controlled conditions. In addition to the HD-SFG measurements, we independently characterized the charges of the graphene electrode using Raman spectroscopy. Combining Raman with HD-SFG lets us fully map the charges of the SiO2-supported graphene electrode/aqueous electrolyte interface and distinguish the different contributions from the graphene electrode and its supporting substrate to the local electric field. Furthermore, by comparing the data collected at the SiO2- and CaF2-supported graphene electrode surfaces, we unveil the impact of the different substrates on the charging of the graphene and the substrate upon applying the electrochemical potentials. Our approach allows us to obtain molecular details of the graphene electrode/aqueous electrolyte interface, including the reorganization of interfacial water molecules and charges of the interface, which are relevant for various technological applications of graphene such as water desalination, chemosensing, biosensing, energy storage and conversion, and neuromorphic iontronics.
![]() | ||
| Fig. 1 O–H stretching spectra at the SiO2-supported graphene/water interface measured by HD-SFG, at different electrochemical potentials vs. Pd/H2. (a) Schematic diagram of the electrochemical flowing liquid cell for Raman and HD-SFG measurements. SiO2-supported graphene, Pd/H2, and Au wire were used as the working electrode (WE), reference electrode (RE), and counter electrode (CE), respectively. The inlet of the flow cell is connected to a variable flow syringe pump to exchange the solution. (b) O–H stretching Im(χ(2)) spectra at various applied potentials for the SiO2-supported graphene electrode. The dashed line indicates the zero line. (c) The differential Im(Δχ(2)) spectra obtained from taking the difference between χ(2) spectra recorded at 10 mM and 100 mM NaClO4 aqueous solutions for the (left panel) SiO2- and (right panel) CaF2-supported graphene electrode. The Im(Δχ(2)) spectra for the CaF2-supported graphene electrode are adapted from ref. 10. The data are offset for clarity. (d) σ0 and σg as a function of the applied potentials for the SiO2- and CaF2-supported graphene electrodes. σ0 was inferred from the Δχ(2) spectra while σg was inferred from the Raman G-band frequency shift of the graphene electrode. (e) Cyclic voltammogram (CV) of the SiO2-supported graphene electrode. The scan rate is 50 mV s−1. The CV curve shows two typical features: the HER region (below −0.23 V where the current density is above 1 μA cm−2, H2O + e− → ½H2 + OH−)48,49 and the double-layer capacitive region (above −0.23 V). We used 10 mM NaClO4 aqueous solution for the experiments shown in (b) and (e). | ||
Such a nonlinear change in the water orientations may arise from the nonlinear change in the net surface charges (σ0) at the graphene electrode/aqueous electrolyte interface. To examine this hypothesis, we measured the χ(2) spectra at two different electrolyte concentrations (c1 = 10 mM and c2 = 100 mM), and then extracted σ0 from the differential spectra Δχ(2)(σ0,V) = χ(2)(σ0(V),c1) − χ(2)(σ0(V),c2). The surface charge can be obtained in the following manner. At the charged interfaces, observed χ(2) is given as the sum of the Stern layer contribution (χ(2)s-term) and the diffuse layer contribution (χ(3)-term) within the Gouy–Chapman theory:33,37,38
| χ(2)(σ0,c) = χ(2)s + χ(3)ϕ0(σ0,c)κ(c)/(κ(c) − iΔkz), | (1) |
![]() | (2) |
The obtained Im(Δχ(2)) spectra at various potentials for the SiO2-supported graphene electrode are shown in Fig. 1c. The signs of the H-bonded O–H band in the Im(Δχ(2)) spectra are positive irrespective of applied potential, manifesting that the net surface charge (σ0) of the whole SiO2-supported graphene electrode is negative. Since the bare SiO2–water interface is intrinsically negatively charged,40–42 the result implies the transparency of the graphene in terms of the substrate–water interaction.10,20,43 The Im(Δχ(2)) spectra monotonically increase with lowering the potentials, indicating a negatively charged surface and an increase in the negative surface charge density, respectively. The corresponding σ0 extracted from the Δχ(2) spectra using eqn (2) is shown in Fig. 1d. Consistent with the nonlinear change in the Im(χ(2)) spectra, σ0 varies in a very nonlinear fashion with the applied potential. It rapidly increases from −40 mC m−2 to −101 mC m−2 when decreasing the applied potential from −0.03 V to −0.63 V, and is insensitive to the applied potentials in the ranges of +0.57 V to −0.03 V and −0.63 V to −1.23 V. The nonlinear change in σ0 explains the nonlinear change in the Im(χ(2)) spectra upon the variation of the applied potentials and suggests the nonlinear variation of the local electric field at the graphene electrode/aqueous electrolyte interface.
Is such a variation of the surface charge upon the applied potential universal for different substrates? To address this question, we compared the current data for the SiO2-supported graphene electrode with the data for the CaF2-supported graphene electrode.10 Because the SiO2 surface is negatively charged at pH ∼ 6, while the CaF2 surface is positively charged10,44 giving that the isoelectric points of SiO2 and CaF2 are in the pH range of 2–3 (ref. 45) and 9–10 (ref. 46 and 47) respectively, the comparison of the SiO2 and CaF2 samples provides a unified view of the impact of the substrate on the graphene electrode/aqueous electrolyte interface. The variations of the Im(Δχ(2)) spectra and the extracted σ0 are displayed in Fig. 1c and d, respectively. Both cases show the nonlinear changes in σ0 at ∼−0.33 V vs. Pd/H2, while the values of σ0 are largely different. This difference reflects the intrinsically different surface charge of the SiO2 and CaF2 substrates upon applying potentials on the graphene electrode. Nevertheless, the trend in the surface charge variation is not different.
To further look deeply at the charge of the graphene sheet supported by these two different substrates, we measured the Raman G-band of the graphene electrodes at different applied potentials, from which we estimated the charges (σg) of the graphene sheets (for details, see Section S1 in the ESI†).50,51 The data is plotted in Fig. 1d. Consistent with previous studies,50,52σg varies linearly vs. the applied potentials, decreasing from +3 mC m−2 to −16 mC m−2 when changing the potential from +0.57 V to −1.23 V for the SiO2-supported graphene electrode. Importantly, we observed the same change in σg with potential within the experimental error, irrespective of different substrates, despite σ0 differing significantly for these two different substrates. This clearly demonstrates that the charges on the graphene sheets upon applying potentials are decoupled from the charges on the substrates. This is reasonable because the impact of the substrate's charges on σg is small, less than 1 mC m−2 even if considering the biggest substrate's charge of 100 mC m−2 according to self-consistent theory (for details, see Section S2 in the ESI†).53,54
By using the analogy of the CaF2 and SiO2 substrates,10 the electrified graphene leads to the hydrogen evolution reaction (HER), altering the local pH near the graphene electrode. To see how the applied potential alters the local pH and the role of the substrate of the graphene electrode, we plotted the comparison of the local pH near the CaF2-supported graphene and SiO2-supported graphene (for details, see Section S3 in the ESI†). The data is shown in Fig. 2. The local pH vs. applied potential is identical within the experimental error, manifesting that the local pH created by the electrified graphene electrodes is independent of its supporting substrate. Not only the surface charge on the graphene electrode but also the local pH created by the electrified graphene electrode are not affected by its supporting substrate. Notably, the same local pH change explains the same nonlinear change trend in σ0 for the SiO2- and CaF2-supported graphene electrode (Fig. 1d). It also verifies that the different Im(Δχ(2)) spectra and σ0 (Fig. 1c and d) for the SiO2- and CaF2-supported graphene electrodes simply arise from the different isoelectric points of the SiO2 and CaF2 substrates.
![]() | ||
| Fig. 2 Pseudocapacitive pH changes near the graphene electrode. Inferred local pH value as a function of the applied potentials for the SiO2- and CaF2-supported graphene electrodes. The data for the CaF2-supported graphene electrode is adapted from ref. 10. | ||
A remaining question is which type of interfacial acid–base equilibrium occurs at the electrified SiO2-supported graphene interface. At +0.57 V, the solution has the original solution pH of ∼5.6, and the SiO2 surface is negatively charged (composed of
SiO−,
SiOH and
Si(OH)2 groups,42,55 where
indicates a surface-bound state). Changing the potential to below −0.23 V, HER occurs (Fig. 1e), raising the local pH at the graphene/aqueous electrolyte interface.10,56 The elevated local pH induces the dissociation of water (I) trapped between the graphene and the SiO2 substrate. Subsequent proton permeation through the graphene (II)24–27 to the bulk water leaves OH− causing the deprotonation of the SiO2 (ref. 27 and 57) and then the increase in σ0(III). The increase in σ0 leads to the enhanced alignment of the H-bonded O–H group pointing up towards the graphene electrode.
| H2O ⇌ OH− + H+, | (I) |
![]() | (II) |
Si(OH)2 + OH− ⇌ Si(OH)O− + H2O. | (III) |
SiOH) and ∼8.5 (Si(OH)2) respectively.27,42,57 We note that the bimodal pKa has been debated, recently. For example, Gibbs-Davis et al.58 argued that there could be three types of silanol surface groups, while Tahara et al.40 argued only one. To further understand the interfacial acid–base equilibria of the SiO2 in the presence of the monolayer graphene electrode, we measured the Im(χ(2)) spectra at the SiO2-supported graphene/aqueous electrolyte interface under different pH conditions. The H-bonded O–H peak area as a function of the solution pH exhibits two inflection points, indicating two interfacial acid–base equilibria with two pKa values of ∼4.3 and ∼9.0 respectively (for details, see Section S3 in the ESI†), which are consistent with the generally accepted bimodal acidity behavior. Those results indicate that the presence of the monolayer graphene electrode hardly affects the interfacial acid–base equilibria of the SiO2 substrate, which is also consistent with previous second-harmonic generation (SHG) measurements.27
The potential-induced deprotonation of SiO2 arises from the HER-induced local pH increase, which starts from an initial pH of ∼5.6. From the above analysis, we can conclude that the potential-induced deprotonation of SiO2 corresponds to the equilibrium (III) with the pKa value of ∼9.0. In any case, the deprotonation of SiO2 explains the increase in σ0 and the H-bonded O–H band upon the decrease in the potential. Variation of the Im(χ(2)) spectra upon applying potentials can be reproduced by changing the solution pH (Fig. 3a–c), further supporting this explanation. The reorganization of the interfacial water at the SiO2-supported graphene electrode surface is consistent with previous observations at the bare SiO2–water interface.40,41,59 Those results verify that the local electric field at the SiO2-supported graphene surface is governed by the HER-induced local pH change and subsequently charging of the SiO2 through interfacial acid–base equilibria. We note that the potentials at which we observe HER-induced local pH changes lie in the capacitive region of the cyclic voltammogram (Fig. 1e, below −0.23 V where the current density is around 1 μA cm−2), constituting an electrochemical mechanism that appears to be capacitive but actually originates from charge transfer processes across the electrode/electrolyte interface. Thus, this reflects the pseudocapacitive effect.10,14 A molecular picture of the pseudocapacitive behaviors at the SiO2-supported graphene/aqueous electrolyte interface is schematically depicted in Fig. 3d.
Remarkably, the alignment of interfacial water saturates at increasingly low potentials below −0.63 V (Fig. 1b and 3a–c). The saturation of the water alignment suggests a saturation of the local pH increase (Fig. 2). Such saturation has also been observed at the CaF2-supported graphene electrode/aqueous electrolyte interface and was attributed to the limited amount of water trapped between the graphene and the CaF2 substrate. For CaF2, dissociation of the trapped water molecules is necessary to increase the local pH.10 This is, however, unlike the case at the SiO2-supported graphene electrode/aqueous electrolyte interface because the charging of SiO2 does not require the consumption of the trapped water molecules (I–III). Rather, we attribute the saturation of local pH increase to the slow HER kinetics. The local pH results from the balance/competition of proton consumption by HER and proton supply by diffusion from the bulk solution. In the potential range from −0.03 V to −0.63 V, the HER rate controls the local pH.10 Towards more negative potential below −0.63 V, the local pH is elevated to ∼10.5 (Fig. 2), giving rise to a large proton concentration gradient of ∼5 pH units across the interface and in turn a fast bulk supply of proton. The catalytic activity of graphene for HER is very weak, manifesting as ultra-slow HER kinetics (for details, see Section S4 in the ESI†).60 As a result, the proton diffusion limits the increase in the local pH at potentials below −0.63 V. Notably, the saturation of interfacial acid–base equilibrium might also play a role in the saturation of water alignment. The deprotonation of SiO2 saturating at pH above 11.0 indicates the surface charges on the SiO2 saturates (Fig. S2†). The highest local pH induced by negative electrochemical potentials is ∼10.5. We attribute the saturation of water alignment to saturation of the surface charge density on SiO2 and/or the diffusion-limit local pH increase. The observation that for both CaF2 and SiO2 substrates we infer the same limiting interfacial pH of ∼10.5 at negative potential points to the dominance of diffusion limitations in determining the local pH increase. This is also consistent with the Tafel plot (see Section S4 in the ESI†).
:
1
:
10) for 60 seconds to remove the graphene layer grown on the backside of the copper foil. After being rinsed with deionized water, the copper foil on the film was then etched away in a 0.1 M ammonium persulfate aqueous solution. Subsequently, the obtained CAB–graphene films were rinsed in deionized water several times to remove residual chemical species, and then were transferred onto the SiO2 substrate. Two gold strips were pre-deposited onto the SiO2 substrate before the transfer, and the CAB–graphene film was put in contact with the gold strips for electrical connection. The samples were dried for more than 12 hours at 110 °C in a vacuum (∼1 mbar) to remove residual water. Finally, the CAB layer on graphene was dissolved in acetone. This method allows us to obtain complete large-area monolayer graphene electrodes up to a centimeter scale.10 Such a large-area graphene electrode is useful for HD-SFG measurements because the laser spot size is usually hundreds of micrometers.
The complex-valued spectra of second-order nonlinear susceptibility (χ(2)) of the graphene/water interface samples were obtained via the Fourier analysis of the interferogram and normalization with that of the SiO2/gold interface. The interferogram of the SiO2/gold interface was collected at the gold strip region of the sample immediately before the sample measurement to ensure a precise and stable reference phase. The phase of the gold thin film is determined by measuring the O–H stretching Im(χ(2)) spectrum of the SiO2-supported graphene/D2O interface via normalization of the signal with that of SiO2/gold. As D2O does not have any vibrational response in this region, and its χ(2) response arises solely from the interface,63 we can determine the phase of gold based on the fact that the Im(χ(2)) spectrum of the SiO2-supported graphene/D2O interface shows a flat zero line.
Footnote |
| † Electronic supplementary information (ESI) available. See DOI: https://doi.org/10.1039/d3fd00107e |
| This journal is © The Royal Society of Chemistry 2024 |