Jump to main content
Jump to site search

Issue 13, 2017
Previous Article Next Article

In vivo toxicological assessment of electrochemically engineered anodic alumina nanotubes: a study of biodistribution, subcutaneous implantation and intravenous injection

Author affiliations

Abstract

Electrochemically engineered anodic alumina nanotubes (AANTs) have recently shown good in vitro biocompatibility. However, in vivo toxicological and pathological studies are required to clarify the bio-safety of this novel nanomaterial. Herein, we present a pioneering pilot toxicity study on AANTs in immune-competent murine models (Balb/c mice, 8 weeks). AANTs were administered by intravenous (IV) injection and subcutaneous (SC) implantation routes considering the future toxicological implications associated with this nanomaterial for potential biomedical applications. AANTs, 736 nm long and 90 nm in outer diameter, were chosen as a nanomaterial model. We demonstrate that IV injected AANTs do not have any effect on the mortality or body weight of these animal models within 28 days at three different doses (20, 50, 100 mg kg−1). The biodistribution of AANTs characterized by fluorescence imaging and inductively coupled plasma revealed the accumulation of AANTs in the liver and spleen after IV injection. When AANTs were injected intravenously, the highest dose of 100 mg kg−1 caused moderate hepatotoxicity, identified by histopathological analysis. The implantation of AANTs subcutaneously and directly under the skin leads to an inflammatory response, which is a typical foreign body reaction. Taken together, this work provides new insights into the toxicity patterns of new nanomaterials such as AANTs and establishes a rationale for the design of functional AANTs for future biomedical applications.

Graphical abstract: In vivo toxicological assessment of electrochemically engineered anodic alumina nanotubes: a study of biodistribution, subcutaneous implantation and intravenous injection

Back to tab navigation
Please wait while Download options loads

Supplementary files

Publication details

The article was received on 20 jan. 2017, accepted on 06 mar. 2017 and first published on 07 mar. 2017


Article type: Paper
DOI: 10.1039/C7TB00222J
Citation: J. Mater. Chem. B, 2017,5, 2511-2523
  •   Request permissions

    In vivo toxicological assessment of electrochemically engineered anodic alumina nanotubes: a study of biodistribution, subcutaneous implantation and intravenous injection

    Y. Wang, I. Zinonos, A. Zysk, V. Panagopoulos, G. Kaur, A. Santos, D. Losic and A. Evdokiou, J. Mater. Chem. B, 2017, 5, 2511
    DOI: 10.1039/C7TB00222J

Search articles by author