Issue 14, 2024

Preparation and application of a Cu-doped antimony electrode to improve the performance of pH measurement in seawater

Abstract

Antimony-based electrodes are widely used in various fields for pH detection due to their low cost. However, their application in the marine environment is significantly hampered by the significant potential drift observed in seawater pH measurements. This study focuses on enhancing the stability of a pure antimony electrode by doping various amounts of copper without compromising its pH response. A series of electrochemical tests demonstrated that the fabricated alloy electrodes exhibited excellent pH response characteristics, including sensitivity, ion selectivity, response time, reversibility, and temperature coefficients. Moreover, the alloy electrodes were more resistant to corrosion than the pure antimony electrode, thereby guaranteeing the stability. Notably, the alloy electrodes containing 63 at% and 70 at% antimony exhibited superior electrochemical characteristics. The surface analysis elucidated that the alloy electrode had reduced oxidation, surface cracks and antimony peeling compared to the pure antimony electrode. Furthermore, the prepared alloy electrodes exhibited excellent pH response and stability in simulated high-salinity seawater and real seawater. The above results highlight that doping cheap copper into antimony can improve the electrode stability by enhancing the corrosion resistance and slowing down the oxidation rate, thus enabling reliable long-time operation in a relatively stable state. These findings provide experimental support for developing novel pH electrodes based on non-noble metals for use in challenging environments such as seawater.

Graphical abstract: Preparation and application of a Cu-doped antimony electrode to improve the performance of pH measurement in seawater

Supplementary files

Article information

Article type
Paper
Submitted
24 Apr 2024
Accepted
22 May 2024
First published
23 May 2024

Analyst, 2024,149, 3803-3814

Preparation and application of a Cu-doped antimony electrode to improve the performance of pH measurement in seawater

Z. Li, L. Zong, T. Xu, C. Zhang and C. Liu, Analyst, 2024, 149, 3803 DOI: 10.1039/D4AN00606B

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements