Noble gas isotope analysis (He to Xe) with an iterative trapping method on a split flight tube mass spectrometer

Abstract

Noble gas isotopes are being increasingly applied in groundwater and fugitive gas tracing and dating studies. Analyzing all five stable noble gases is important to acquire as much geological information as possible. However, Ar–Kr separation has been a main challenge for noble gas analysis because Ar is over eight thousand times more abundant than Kr. The residual Ar released with Kr is considerable and interferes with the Kr measurement. This study explores a simple and iterative trapping method for Ar–Kr separation. This iterative trapping method improves both noble gas trapping efficiency and time of the whole procedure. The Helix SFT is a static vacuum gas-source mass spectrometer for the high-precision analysis of He by the simultaneous collection of 3He and 4He using a split flight tube. It is also capable of measuring isotopes of Ne up to Xe through peak jumping, although encumbered by the issue of remnant magnetism in the pole pieces which offsets the He peaks after measuring heavier noble gases. This study tested the performance of the Helix SFT using a new inversed tuning protocol that resolves the issue of remnant magnetism of the pole pieces when jumping back from higher masses for He analysis. With a newly designed pneumatic processing line and the iterative trapping method, noble gases have been successfully separated and yield satisfying results. Sensitivities of this analysis system have been determined for He (1.72 × 10−4 A Torr−1) at a trap current of 400 μA, Ne (9.79 × 10−5 A Torr−1) at 200 μA, Ar (2.28 × 10−4 A Torr−1) at 125 μA, Kr (5.09 × 10−4 A Torr−1) and Xe (1.01 × 10−3 A Torr−1) at 200 μA. The 1σ precision of the isotopic ratios in air standards is 3He/4He (±1.39%), 20Ne/22Ne (±0.26%), 40Ar/36Ar (±0.19%), 86Kr/84Kr (±0.09%), and 136Xe/130Xe (±0.22%). The iterative trapping method and the inversed tuning protocol allow the Helix SFT to measure beyond He despite the remnant magnetism of the pole pieces.

Graphical abstract: Noble gas isotope analysis (He to Xe) with an iterative trapping method on a split flight tube mass spectrometer

Supplementary files

Article information

Article type
Paper
Submitted
05 May 2022
Accepted
10 Jun 2022
First published
10 Jun 2022

J. Anal. At. Spectrom., 2022,37, 1565-1572

Noble gas isotope analysis (He to Xe) with an iterative trapping method on a split flight tube mass spectrometer

E. Zuo, A. Lapp, G. St-Jean, T. Graham, H. Cornejo and I. Clark, J. Anal. At. Spectrom., 2022, 37, 1565 DOI: 10.1039/D2JA00153E

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements