Validating the high-precision measurement of Mo isotopes at the 5 ng level using double spike MC-ICP-MS

Abstract

With recent advancements in analytical methods of Mo isotopes, the δ98/95Mo ratios of most geological and environmental samples can be determined. Still, it remains a challenge to obtain high-precision Mo isotope data for low-Mo samples with complex matrices such as igneous and plant samples. Here, we present an improved Mo purification and cleaning resin scheme for reducing the total procedure blank to ≤0.16 ng using common Muromac®1X8(AG1-X8) anion and AG50-X8 cation resins. By an improved Aridus II with ice chamber in sample introduction system (SIS) and adding nitrogen (N2), high sensitivity measurement (95Mo signal intensity: 200–330 V ppm−1) of Mo isotopes was achieved on Neptune Plus MC-ICP-MS. Thus, the sample size containing 30–60 ng Mo is sufficient to be purified, and isotope measurement with high-precision (≤0.06‰, 2SD) can be determined at a concentration of 3–10 ng level using a 97Mo–100Mo double spike. NIST 3134 (0.00 ± 0.05‰), SGR-1b (0.41 ± 0.05‰), NOD-P-1 (−0.86 ± 0.03‰), IAPSO (2.07 ± 0.04‰), and other international reference materials (RMs) were analyzed at 3, 5, 10, and 20 ng mL−1 levels to be in excellent agreement with the published δ98/95Mo values, demonstrating that good accuracy and precision of Mo isotope analysis can be achieved with an injecting sample size as small as 5 ng Mo. Our improved method can be applied to various geological and environmental samples. The δ98/95Mo of CLB-1 (1.25 ± 0.03‰), JDO-1 (0.50 ± 0.02‰), GSV-2 (0.47 ± 0.02‰), and other 38 RMs with relatively higher and lower Mo concentrations are reported for the first time. The total average δ98/95Mo ratio of 8 soils and 18 sediments is 0.003 ± 0.277‰ (1SD, n = 26), slightly lighter than that of the upper continent crust (0.05–0.15‰). The δ98/95Mo ratios (0.23–0.79‰, n = 8) of plant and animal origins from the land show they are enriched in heavy isotopes relative to the bulk silicate earth (BSE). The δ98/95Mo ratios of carbonates are much lower than that in seawater.

Graphical abstract: Validating the high-precision measurement of Mo isotopes at the 5 ng level using double spike MC-ICP-MS

Supplementary files

Article information

Article type
Paper
Submitted
28 Dec 2021
Accepted
18 Mar 2022
First published
18 Mar 2022

J. Anal. At. Spectrom., 2022,37, 1063-1075

Validating the high-precision measurement of Mo isotopes at the 5 ng level using double spike MC-ICP-MS

H. Zhu, J. Zhu, D. Tan, X. Lin, K. Lu and W. Yang, J. Anal. At. Spectrom., 2022, 37, 1063 DOI: 10.1039/D1JA00465D

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements