Issue 41, 2019

High-throughput amperometric determination of tetracycline residues in milk and quality control of pharmaceutical formulations: flow-injection versus batch-injection analysis

Abstract

This paper demonstrates a potential use of the reduced graphene-oxide (rGO) modified electrode associated with FIA and BIA systems for rapid, simple and sensitive determination of tetracycline residues in milk samples as well as quality control of pharmaceutical formulations. Experiments involving cyclic voltammetry using the rGO-modified electrode evidenced the anticipation of potential and increase in analytical signal (7-fold for the first oxidation process) when compared to the unmodified electrode, which demonstrated the electrocatalytic effect of rGO responsible for the improved selectivity of the sensor. High- or low-fat milk samples were only diluted in a supporting electrolyte (BR buffer solution) while pharmaceutical tablets were powdered and dissolved in the same electrolyte, and no interferences from the sample matrix were verified in the amperometric determination of tetracycline. Both analytical methods showed high precision (RSD < 3%), low detection limit (1.17 μmol L−1 for FIA and 0.038 μmol L−1 for BIA), high sample throughput (103 h−1), proper accuracy evaluated using recovery values (84–117%) and by comparison with Ultra-Fast Liquid-Chromatography (UFLC) obtaining statistically similar results (95% confidence level). The BIA method presented superior performance regarding sample throughput and especially detection limit due to the high flow injection rate of the system, which is mandatory for the analysis of tetracycline residues in milk. The rGO-modified electrode was stable, sensitive and precise under high-flow conditions even in the presence of high-fat milk samples.

Graphical abstract: High-throughput amperometric determination of tetracycline residues in milk and quality control of pharmaceutical formulations: flow-injection versus batch-injection analysis

Article information

Article type
Paper
Submitted
15 Aug 2019
Accepted
30 Sep 2019
First published
02 Oct 2019

Anal. Methods, 2019,11, 5328-5336

High-throughput amperometric determination of tetracycline residues in milk and quality control of pharmaceutical formulations: flow-injection versus batch-injection analysis

L. V. Faria, A. P. Lima, F. M. Araújo, T. P. Lisboa, M. A. C. Matos, R. A. A. Munoz and R. C. Matos, Anal. Methods, 2019, 11, 5328 DOI: 10.1039/C9AY01759C

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements