Issue 33, 2019

A sample pre-treatment-free electrochemical immunosensor with negative electro-pulsion for the quantitative detection of acrylamide in coffee, cocoa and prune juice

Abstract

Acrylamide is a potential carcinogen mainly found in heat-processed foods and its advised maximum intake is 2.6 μg kg−1 of body weight per day to prevent cancer risk; hence, a rapid detection method for acrylamide is strongly needed for food monitoring. In this study, a sample pre-treatment-free electrochemical immunosensor was developed via a displacement assay. The leaving of the anti-acrylamide antibody from the electrode surface is the predominant factor for an effective displacement assay. The dissociation rate of the antibody from the surface-bound hapten was enhanced by applying a negative electro-pulsion to the electrode surface. The pulsing duration and pulsing potential for the dissociation of the anti-acrylamide antibody were experimentally optimized. A three-level three-factorial Box–Behnken experimental design was employed in the present study to confirm the optimal displacement condition required based on a minimal experiment number (17 trials) without involving all possible experimental combinations. A linear dynamic range from 0.01 to 35.00 μg mL−1 was obtained, with the limit of detection (LOD) of 3.84 ng mL−1. The accuracy of the developed immunosensor was validated by using a standard method: gas chromatography-mass spectrometry (GC-MS). Moreover, the recoveries obtained from the spiked samples ranged between 90.33% and 99.23%. Hence, this method showed high selectivity and sensitivity for acrylamide determination in liquid food samples. Due to its simplicity of use, which excludes sample pre-treatment steps, this developed immunosensor has the potential to provide direct and quantitative acrylamide detection that is not significantly affected by food matrices.

Graphical abstract: A sample pre-treatment-free electrochemical immunosensor with negative electro-pulsion for the quantitative detection of acrylamide in coffee, cocoa and prune juice

Supplementary files

Article information

Article type
Paper
Submitted
25 May 2019
Accepted
23 Jul 2019
First published
24 Jul 2019

Anal. Methods, 2019,11, 4299-4313

A sample pre-treatment-free electrochemical immunosensor with negative electro-pulsion for the quantitative detection of acrylamide in coffee, cocoa and prune juice

P. Y. Lau, K. L. Ng, N. A. Yusof, G. Liu, Y. Alias and S. M. Khor, Anal. Methods, 2019, 11, 4299 DOI: 10.1039/C9AY01102A

To request permission to reproduce material from this article, please go to the Copyright Clearance Center request page.

If you are an author contributing to an RSC publication, you do not need to request permission provided correct acknowledgement is given.

If you are the author of this article, you do not need to request permission to reproduce figures and diagrams provided correct acknowledgement is given. If you want to reproduce the whole article in a third-party publication (excluding your thesis/dissertation for which permission is not required) please go to the Copyright Clearance Center request page.

Read more about how to correctly acknowledge RSC content.

Social activity

Spotlight

Advertisements